Catalog excerpts
Powerware series Powerware Hot Sync Technology Paralleling UPS technology The number one function of a UPS is to supply continuous conditioned, reliable electricity to a critical load. In case of a single unit, reliability can be increased by modular design, where redundant internal modules can take over each others’ tasks-, if one of the modules fails. To further increase reliability, a true parallel configuration can be employed, where two or more units share the load. A failed unit is isolated while the remaining ones continue to support the critical load. Competitive UPS products on the market utilise centralised or distributed load-sharing technology with the master-slave principle, which introduces a risk of single point failure. The absolute reliability of a UPS system can be achieved with patented Powerware Hot Sync® parallel load-sharing technology. (Figure 1) Hot Sync technology is designed for parallel redundant N+1 systems to satisfy 24/7 applications. It can also be used in parallel capacity systems to benefit from scalability for customers’ everincreasing load demands. Hot Sync erases single point of failure, with an ability to synchronise and support critical loads independently of other UPS modules in the system. UPS modules can share loads without any communication wiring to the outside world. User benefits • Easy and modular parallel UPS system upgrade with additional capacity or redundancy • Erases single point of failure 20% Utility Failure probability / year • Available for both single- and three -phase products to meet any mission-critical need up to 2.5 MVA (400V) systems Single UPS Modular UPS Parallel redundant UPS Hot Sync Figure 1. Availability figures for utility and UPS configurations in case of repeated power failures and distu
Open the catalog to page 1Powerware Hot Sync Technology The secret here is a patented built-in digital signal processor (DSP) algorithm, running continuously in each unit. It drives the UPS outputs toward synchronisation and takes care of load sharing. If there is a common bypass available, it is used as valid synchronisation source for output. In the absence of a common bypass, the processor makes subtle adjustments to the inverter frequency on the basis of output power level measurement in order to find a common frequency and load balance among the units. There exists, as shown in Figure 2, a relationship between...
Open the catalog to page 2All Powerware catalogs and technical brochures
-
5 series UPS
8 Pages
-
Eaton 3S UPS
2 Pages
-
Seismic S-Series Enclosures
4 Pages
-
Blanking Panels
2 Pages
-
Eaton RACKPACKIT
4 Pages
-
Surge protection
8 Pages
-
UPS basics
8 Pages
-
Strategies for design
6 Pages
-
Eaton Marine UPS
7 Pages
-
Eaton 9PHD
2 Pages
-
Power Xpert 9395P
20 Pages
-
Eaton 93PM 30-200kW
12 Pages
-
Eaton 93PS UPS
9 Pages
-
Eaton 93PS IT
4 Pages
-
Eaton 93E UPS 80-200kVA
4 Pages
-
Eaton Ellipse PRO
2 Pages
-
Eaton Ellipse ECO
2 Pages
-
Eaton 9155/9355 UPS
8 Pages
-
UPS Quick Guide
3 Pages
-
Internet Protection
1 Pages
-
Eaton Protection Station
2 Pages
-
S-Series Enclosures Brochure
20 Pages
-
Eaton 9315 UPS Brochure
12 Pages
-
Eaton 9170+ UPS Brochure
6 Pages
-
5125 Family Brochure
6 Pages
-
Vantage S2 Brochure
16 Pages
-
Eaton 5S
2 Pages
-
Eaton BladeUPS MBM Brochure
2 Pages
-
Eaton 3S UPS
2 Pages
-
Eaton 9130 Rack UPS
4 Pages
-
Eaton 5PX UPS
2 Pages
-
Eaton 5P Tower UPS
2 Pages
-
Eaton 5SC UPS
2 Pages
-
Data Center Line Card
1 Pages
-
Eaton ePDU Product Catalog
48 Pages
Archived catalogs
-
TS50
126 Pages
-
Product catalogue
118 Pages
-
Powerware Product Catalog
40 Pages