Eaton 9PHD
2Pages

{{requestButtons}}

Catalog excerpts

Eaton 9PHD - 1

Datasheet Eaton 9PHD Industrial UPS Eaton 9PHD Heavy Duty UPS 30–200 kW Strong and Smart Power Protection Reliable, Safe and Cost Efficient Strong design for demanding industrial environments • Protection against dirt, dust, water and moist with cover options from IP23 to IP54 • Conformally coated PCB boards • Strong cabinet for vibration and seismic environments • 1.5mm cover plates for robust use Smart technology for maximizing reliability • Touch screen display for easier operation • Modular design allows building fault tolerant N+1 units • Redundant monitored cooling fans in each power module • Battery start feature • Eaton’s unique Hot Sync wireless paralleling for building n+1 systems with several UPS units Smart technology for minimizing operating cost • The 9PHD UPS sets new standards, with an operating efficiency level up to 97% in double conversion mode • > 99% superior efficiency is delivered in Energy Saver System mode (ESS) • Power factor 1 increases unit power by 10-20% compared to average UPS Easy deployment for optimizing installation costs • Front access for installation and service Designed, Manufactured and Tested in Finland • Lifting lugs for easier unit handling during installation • Suitable for 3-wire and 4-wire networks and voltage range of 380V-480V without transformers • Small footprint due compact power electronics and internal transformer options • Cabinet supports use of halogen free cables, double cables or large cables for installation Safe installation and operation • Unit has halogen free cables • Connectors in battery strings to increase safety during battery replacement • Battery breaker inside battery cabinet isolated from hydrogen gases • Internal maintenance bypass sw

Open the catalog to page 1
Eaton 9PHD - 2

Eaton 9PHD Industrial UPS 30–200 kW Technical specifications General UPS output power rating (1.0 p.f.) Output wiring Nominal voltage rating (configurable) Efficiency in double conversion mode With optional transformer Efficiency in Energy Saver System (ESS) Output UTHD Inverter/rectifier topology Transformer-free IGBT with PWM < 5% (reference non-linear load) Audible noise Rated output power factor Permitted load power factor Ambient temperature 0°C to 40°C at 1000m altitude, higher temperatures are optional Overload when bypass available Note: Bypass fuses may limit the overload Ingress...

Open the catalog to page 2

All Powerware catalogs and technical brochures

  1. Eaton 3S UPS

    2 Pages

  2. 5 series UPS

    8 Pages

  3. TS50

    126 Pages

  4. UPS basics

    8 Pages

  5. Eaton 5S

    2 Pages

  6. Eaton 3S UPS

    2 Pages

Archived catalogs