LIFEPO4 + Graphene PRODUCT MANUAL This Product Manual applies only to: www.powersyncenergy.com (877) 459-4591 © 2023 POWERSYNC Energy Solutions, LLC 01/31/23 LFP Graphene Product Manual
Open the catalog to page 1SAFETY INFORMATION About This installation Manual Before Installation: Safety Check BATTERY SPECIFICATIONS BATTERY INSTALLATION Pre-Installation Charging Module to Module Connections LFP+G DUAL PURPOSE LIMITED WARRANTY www.powersyncenergy.com (877) 459-4591 © 2023 POWERSYNC Energy Solutions, LLC 01/31/23 LFP Graphene Product Manual
Open the catalog to page 2SAFETY INFORMATION WARNING WARNING: Read this entire document before installing the POWERSYNC Energy Storage Batteries. Failure to follow all instructions and warnings within this document could result in electric shock, serious injury, or death and may damage the battery module or ancillary components. The information contained in this manual is accurate at the time of publication. However, information contained herein is subject to change without notice. For the latest information regarding POWERSYNC Energy Solutions products and installation guides, go to https://powersyncenergy.com/product-literature/#lfpg...
Open the catalog to page 3WARNINGS Please read and comply with the following conditions of installation and use of the battery, incorrect installation using the battery may cause personal injury or damage to the product. : Use ONLY POWERSYNC Energy Solutions LiFePO4 battery modules. DO NOT CONNECT ANY OTHER BATTERY MODULES. DOING SO WILL VOID THE WARRANTY AND MAY DAMAGE THE POWERSYNC LiFePO4 BATTERY. Over-voltages or wrong wiring can damage the battery pack and cause deflagration, which can be extremely dangerous. Batteries must be connected with batteries of the same voltage and capacity and model number. DO NOT open...
Open the catalog to page 4BEFORE YOU START Read all the safety information provided in this document prior to installing and/or operating the equipment. Ensure that the batteries are being operated in compliance with the Product Warranty. Contact POWERSYNC Energy Solutions Customer Support at (877) 459-4591 immediately if you have any questions about the handling, operation and safe use of the battery. BEFORE INSTALLATION: • Remove any possible metallic items that may be at risk of an electrical short such as jewelry, watches, pens, metal bars, or frames, etc. All tools must be properly insulated The POWERSYNC LiFePO4...
Open the catalog to page 5BATTERY SPECIFICATIONS Model Number PERFORMANCE SPECIFICATIONS Nominal Voltage Nominal Capacity Energy (At 100% DOD) Chemistry Internal Resistance Cycle Life Self Discharge Rate DISCHARGE SPECIFICATIONS Max Continuous Current Pulse Cranking Amps (PCA) Recommended Cut-off Voltage Under Voltage (Recovery) CHARGE SPECIFICATIONS Max Continuous Current Rec. Charge (Bulk / Absorb / Float) Equalization (60 min every 7 days) Over Voltage (Recovery) MECHANICAL SPECIFICATIONS Case Protection Rating Dimensions (L x W x H) Weight (lbs./Kg.) Terminal Type ENVIRONMENTAL SPECIFICATIONS Operating Temperature...
Open the catalog to page 6Model Number Nominal Voltage Nominal Capacity PERFORMANCE SPECIFICATIONS Internal Resistance Cycle Life* Self Discharge Rate DISCHARGE SPECIFICATIONS Max Continuous Current Pulse Cranking Amps (PCA) Recommended Cut-off Voltage Under Voltage (Recovery) MODULE CHARGE SPECIFICATIONS Max Continuous Current Rec. Charge (Bulk / Absorb / Float) Equalization (60 min every 7 days) Over Voltage (Recovery) MECHANICAL SPECIFICATIONS Case Protection Rating Dimensions (L x W x H) Weight (lbs./Kg.) Terminal Type ENVIRONMENTAL SPECIFICATIONS Operating Temperature UN3480, Class 9, UN38.3 www.powersyncenergy.com...
Open the catalog to page 7BATTERY INSTALLATION IMPORTANT NOTICE: Do not place battery modules on top of one another without using proper racking or cabinet solutions. For more information about appropriate enclosures, see the Enclosure Information section of this installation manual. PRE-INSTALLATION CHARGING It is required by law for lithium battery modules to be shipped at or below 50% state of charge. Therefore upon arrival, your battery may be at a low state of charge. If more than one battery module will be connected in parallel or series, it is a good practice to individually charge all batteries to a full charge...
Open the catalog to page 8MODULE TO MODULE CONNECTIONS Module Connection Torque: Max of 7.5 Nm (5.5 ft/lbs) MODULE CONNECTION OVERVIEW The battery modules are designed for up to 4 series or 4 parallel connections. Always use an appropriately rated cable for the voltage and current. When connecting SAE connectors, always connect to the SAE terminals. When M8 connectors, always connect to the M8 terminals. When assembling the batteries in Series or Parallel, make sure there is less than a 0.5V voltage difference between each of the battery modules. FOR PARALLEL CONNECTIONS Up to 4 modules can be connected in parallel. Connect...
Open the catalog to page 9We encourage you to make use of the LFP+G Google Play Store or Apple App Store application which will provide you with more detailed information than what is available to be seen on the module State of Charge “SOC” meter. NOTE: • When battery modules are connected in series or parallel, the app will connect to one battery as representative of the other batteries in the string. The information provided by the SOC meter on the battery module may be different than what is being reported on the app. If this occurs, rely on the information that is being provided by the app during high current charging...
Open the catalog to page 10LFP+G DUAL PURPOSE LIMITED WARRANTY POWERSYNC Energy Solutions LLC (“POWERSYNC”) warrants, to the original purchaser (“User”), that its starter and deep cycle lithium batteries (“Battery(ies)”) listed in the table below, if purchased from POWERSYNC or an authorized distributor, dealer or installer in the United States and Canada, and used in engine start and deep cycle applications will be free from defects in material and/or workmanship from the date of purchase and for the duration listed in the table below (“Warranty Period”). FULL REPAIR / REPLACEMENT PERIOD PRORATED PERIOD TOTAL WARRANTY...
Open the catalog to page 11