Unit 8A Arnhem Road Newbury. RG14 5RU Three phase input Voltage range Current range cTUVus safety approval Master/Slave parallel and series operation with voltage and current sharing Excellent dynamic response to load changes Stacking is allowed, space between units is not required Protected against all overload and short circuit conditions High power system configuration from multiple units EMC surpasses CE requirements: low emission & high immunity Low audible noise: temperature controlled fans 19" rack mounting or laboratory use (feet included) Remote sensing Designed for long life at full power Available options: analog & digital Interfaces, High Speed Programming, Digital Encoders, Seq
Open the catalog to page 1SM 15-400 SM 30-200 SM 45-140 SM 60-100 Output voltage current Input AC 3 phase, 48 - 62 Hz for use at 380 V, 400 V, 415 V nominal line - line voltage Option P165 for use at 440 V, 480 V (USA) (operates from 360 V, but at derated output, 5300 W@360 V) current (400 V / 3 ph, full load) power factor, 100%, 50% load rms (BW=300 kHz) CC p-p (BW=20 MHz) CC CC-ripple at full load Temp. coeff., per °C CV CC Stability after 1 hr warm-up during 8 hrs CV CC tamb = 25 ± 1 °C, Vin = 400 V AC internal voltage sensing for CC-stab. internal fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) Efficiency...
Open the catalog to page 2Status outputs CC - status LIM - status OT - status PSOL - status ACF - status DCF - status CC - operation CV or CC limit Over Temperature Power Sink Overload AC - Fail DC - Fail 1) 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 both NO and NC contact both NO and NC contact ) output ± 5% beyond set point with + 5V, 1 mA or relay contact Remote ShutDown contact at rear panel, see photo of rear panel on page 1-6 AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote-ShutDown, Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV- and CC- mode Indicators...
Open the catalog to page 3Power Supply Standard EN 61204-3, Emission: residential, light industrial environment (CISPR22-Class B) Immunity: industrial environment Generic Emission Generic Immunity EN 61000-6-3, residential, light industrial environment (EN 55022 B) EN 61000-6-2, industrial environment − 20 to + 50 °C derate output to 75% at 60 °C Operating Temperature at full load Storage temperature Output shuts down in case of insufficient cooling Thermal protection SM 15-400 SM 30-200 SM 45-140 SM 60-100 Hold-Up time Vout = 100%, Iout = 100% Vout = 85%, Iout = 100% Vout = 100%, Iout = 50% @ 400 V AC input Turn on delay...
Open the catalog to page 4Typical Applications • • • Solar inverter testing, PV-Simulation Controlled Battery (dis)charging Plasma chambers Lasers Hybrid Car test systems Driving PWM-Controlled DC motors Accurate current sources Automotive battery simulations Aerospace and military equipment ATE in industrial production lines Available Options High Speed Programming Increased Output Power Two-Quadrant Output: Power sink The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be increased by about 10%....
Open the catalog to page 5Hz, 3 phase, unless otherwise noted. The information in this document is subject to change without notice Connections analog programming connector Status Relay Programming Connectors Ethernet user I/O (all optional) isolated analog (all optional) Safety Covers supplied for in- and output (not shown) Note: SM300-20 and SM 600-10 standard with isolated analog programming via ISO AMP on CON H (CON E is not available).
Open the catalog to page 63 Pages
6 Pages
6 Pages
4 Pages
3 Pages
8 Pages
1 Page
2 Pages
1 Page
1 Page
4 Pages
4 Pages
4 Pages
3 Pages
4 Pages
2 Pages
2 Pages
4 Pages
5 Pages
6 Pages
4 Pages
2 Pages
2 Pages
1 Page
1 Page
3 Pages
3 Pages
5 Pages
1 Page
1 Page
15 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
6 Pages
6 Pages
6 Pages
2 Pages
2 Pages
3 Pages
3 Pages
1 Page
1 Page
1 Page
5 Pages
5 Pages
1 Page
4 Pages
6 Pages
3 Pages
1 Page
2 Pages
6 Pages
6 Pages
9 Pages
5 Pages
10 Pages
8 Pages
6 Pages
3 Pages
5 Pages
6 Pages
3 Pages
3 Pages
3 Pages
2 Pages
4 Pages
4 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
4 Pages
1 Page
2 Pages
1 Page
2 Pages
1 Page
2 Pages
10 Pages