sm6000
1 /6Pages

sm6000

sm6000
1 /6Pages

Catalog excerpts

sm6000-1

Unit 8A Arnhem Road Newbury. RG14 5RU Three phase input Voltage range Current range cTUVus safety approval Master/Slave parallel and series operation with voltage and current sharing Excellent dynamic response to load changes Stacking is allowed, space between units is not required Protected against all overload and short circuit conditions High power system configuration from multiple units EMC surpasses CE requirements: low emission & high immunity Low audible noise: temperature controlled fans 19" rack mounting or laboratory use (feet included) Remote sensing Designed for long life at full power Available options: analog & digital Interfaces, High Speed Programming, Digital Encoders, Seq

 Open the catalog to page 1
sm6000-2

SM 15-400 SM 30-200 SM 45-140 SM 60-100 Output voltage current Input AC 3 phase, 48 - 62 Hz for use at 380 V, 400 V, 415 V nominal line - line voltage Option P165 for use at 440 V, 480 V (USA) (operates from 360 V, but at derated output, 5300 W@360 V) current (400 V / 3 ph, full load) power factor, 100%, 50% load rms (BW=300 kHz) CC p-p (BW=20 MHz) CC CC-ripple at full load Temp. coeff., per °C CV CC Stability after 1 hr warm-up during 8 hrs CV CC tamb = 25 ± 1 °C, Vin = 400 V AC internal voltage sensing for CC-stab. internal fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) Efficiency...

 Open the catalog to page 2
sm6000-3

Status outputs CC - status LIM - status OT - status PSOL - status ACF - status DCF - status CC - operation CV or CC limit Over Temperature Power Sink Overload AC - Fail DC - Fail 1) 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 both NO and NC contact both NO and NC contact ) output ± 5% beyond set point with + 5V, 1 mA or relay contact Remote ShutDown contact at rear panel, see photo of rear panel on page 1-6 AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote-ShutDown, Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV- and CC- mode Indicators...

 Open the catalog to page 3
sm6000-4

Power Supply Standard EN 61204-3, Emission: residential, light industrial environment (CISPR22-Class B) Immunity: industrial environment Generic Emission Generic Immunity EN 61000-6-3, residential, light industrial environment (EN 55022 B) EN 61000-6-2, industrial environment − 20 to + 50 °C derate output to 75% at 60 °C Operating Temperature at full load Storage temperature Output shuts down in case of insufficient cooling Thermal protection SM 15-400 SM 30-200 SM 45-140 SM 60-100 Hold-Up time Vout = 100%, Iout = 100% Vout = 85%, Iout = 100% Vout = 100%, Iout = 50% @ 400 V AC input Turn on delay...

 Open the catalog to page 4
sm6000-5

Typical Applications • • • Solar inverter testing, PV-Simulation Controlled Battery (dis)charging Plasma chambers Lasers Hybrid Car test systems Driving PWM-Controlled DC motors Accurate current sources Automotive battery simulations Aerospace and military equipment ATE in industrial production lines Available Options High Speed Programming Increased Output Power Two-Quadrant Output: Power sink The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be increased by about 10%....

 Open the catalog to page 5
sm6000-6

Hz, 3 phase, unless otherwise noted. The information in this document is subject to change without notice Connections analog programming connector Status Relay Programming Connectors Ethernet user I/O (all optional) isolated analog (all optional) Safety Covers supplied for in- and output (not shown) Note: SM300-20 and SM 600-10 standard with isolated analog programming via ISO AMP on CON H (CON E is not available).

 Open the catalog to page 6

All Powersolve Electronics catalogs and technical brochures

  1. SM15K Series

    6  Pages

  2. ESB101 Series

    4  Pages

  3. EPS SERIES

    1  Page

  4. PPS60 Series

    1  Page

  5. PS50W Series

    4  Pages

  6. PS50 Series

    4  Pages

  7. CFM05 Series

    2  Pages

  8. PSY300 Series

    4  Pages

  9. MDC080 AC

    5  Pages

  10. ESB101

    4  Pages

  11. ESB00351

    2  Pages

  12. PPT10E

    2  Pages

  13. PSCH30

    1  Page

  14. PSCH15

    1  Page

  15. p-in1504000

    3  Pages

  16. P-IN2902000

    3  Pages

  17. ms-adapter

    1  Page

  18. al24-48

    1  Page

  19. Delta catalog

    15  Pages

  20. sx series

    4  Pages

  21. s280

    2  Pages

  22. es300

    4  Pages

  23. 600S

    2  Pages

  24. 1200S

    2  Pages

  25. sm800

    6  Pages

  26. sm3000

    6  Pages

  27. sm3300

    6  Pages

  28. 5u series

    2  Pages

  29. PKS06-USB

    2  Pages

  30. PKS11-USB

    3  Pages

  31. PKS15-2USB

    3  Pages

  32. PLV120-USB

    1  Page

  33. EST150

    4  Pages

  34. ES150 Series

    6  Pages

  35. TPM Series

    1  Page

  36. 240S Series

    2  Pages

  37. SM1500 Series

    6  Pages

  38. PAE800 Series

    6  Pages

  39. MP Series

    10  Pages

  40. C(AC) Series

    8  Pages

  41. CFM40-60

    2  Pages

  42. TOL series

    1  Page

  43. TOF series

    1  Page

  44. PA 150 series

    2  Pages

  45. AHP200 series

    2  Pages

  46. PPS40 Series

    3  Pages

  47. CFM20 Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.