Catalog excerpts
Unit 8A Arnhem Road Newbury. RG14 5RU Voltage range Current range Three phase input Designed for long life at full power Excellent dynamic response to load changes Protected against all overload and short circuit conditions High power system configuration from multiple units low emission & high immunity 19" rack mounting or for laboratory use Master/Slave parallel and series operation with voltage and current sharing Stacking is allowed, space between units is not required (feet included) Low audible noise: fans are temperature controlled Available options: High Speed Programming, Interfaces, Remote sensing Extra Isolation, Sequencer, Power Sink
Open the catalog to page 1SM 15-200 D SM 30-100 D SM 45-70 D SM 70-45 D SM 120-25 D SM 300-10 D Output voltage current power factor (380 V / 3 phase) 100% load 50% load contact factory contact factory contact factory contact factory contact factory contact factory Input AC 3 phase, 48 - 62 Hz for use at 380 V, 400 V, 415 V nominal line - line voltage DC fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) Efficiency AC 3 phase input, full load Regulation Load 0 - 100% Line 342 - 457 V AC Temp. coeff., per °C Stability after 1 hr warm-up during 8 hrs during 30 hrs Analog Programming Programming inputs...
Open the catalog to page 2Programming speed Standard Version (resistive load) Rise time (10 - 90%) output voltage step time, (100 % load) time, (10 % load) Fall time (90 - 10%) output voltage step time, (100 % load) time, (10 % load) Programming bandwidth small signal large signal,(100 % load) large signal,(10 % load) Programming speed High Speed Version (resistive load) Rise time (10 - 90%) output voltage step time, (100 % load) time, (10 % load) Fall time (90 - 10%) output voltage step time, (100 % load) time, (10 % load) Recovery time recovery within di/dt of load step time, @ 50 - 100% load step max. deviation...
Open the catalog to page 3Hold-Up time 100% load 50% load Turn on delay after mains switch on Inrush current Phase loss The power supply will continue to operate on one phase but at 90% of Vout(max) (a SM30-100D adjusted at 27 V will continue to deliver 27 V after phase loss) Series operation max. total voltage Master / Slave operation Parallel operation max. total current Master / Slave operation Remote sensing max. voltage drop per load lead OVP / OVL adjustment range Potentiometers front panel control with knobs resolution screwdriver adjustment at front panel at rear panel Meters scale voltage scale current...
Open the catalog to page 4Typical Applications • • • • Solar inverter testing, PV-Simulation Plasma chambers Hybrid Car test systems ATE in industrial production lines • Automotive battery simulations • Controlled battery (dis)charging • Lasers • Driving PWM-controlled DC-motors • Accurate current sources • Aerospace and military equipment Available Options Increased Output Power High speed programming Two-Quadrant Output: Power sink The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be...
Open the catalog to page 5OVP/OVL status CC=Constant Current OVP=Over Voltage Protector OVL=Over Voltage Limit (Protection) 50 Hz unless otherwise noted. Connections programming connector Analog Programming (standard) isolated analog (all optional) Output Terminals Safety Cover supplied for input. Cover for output must be ordered separately.
Open the catalog to page 6All Powersolve Electronics catalogs and technical brochures
-
TMR-9WI Series
3 Pages
-
PSCH30
1 Pages
-
Power Banks Brochure
6 Pages
-
SM15K Series
6 Pages
-
ESB101 Series
4 Pages
-
TRACOPOWER THI3 Series
3 Pages
-
TRACOPOWER TSP-BCMU battery
8 Pages
-
EPS SERIES
1 Pages
-
PUPS22 & 44 Series
2 Pages
-
PPS60 Series
1 Pages
-
EPS SERIES 1000
1 Pages
-
PS50W Series
4 Pages
-
PS50 Series
4 Pages
-
TEQ300WIR Series
4 Pages
-
TRACO TES1V Series
3 Pages
-
TRACO TES1 Series
4 Pages
-
CFM10-15 Series
2 Pages
-
CFM05 Series
2 Pages
-
PSY300 Series
4 Pages
-
MDC080 AC
5 Pages
-
ESB00163 16A/ESB00323 32A
6 Pages
-
ESB101
4 Pages
-
ESB00351
2 Pages
-
PPT10E
2 Pages
-
PSCH30
1 Pages
-
PSCH15
1 Pages
-
p-in1504000
3 Pages
-
P-IN2902000
3 Pages
-
sm3300-interfaces
5 Pages
-
ms-adapter
1 Pages
-
al24-48
1 Pages
-
Delta catalog
15 Pages
-
sx series
4 Pages
-
s280
2 Pages
-
es300
4 Pages
-
600S
2 Pages
-
1200S
2 Pages
-
sm800
6 Pages
-
sm3300
6 Pages
-
sm6000
6 Pages
-
5u series
2 Pages
-
PKS06-USB
2 Pages
-
PKS11-USB
3 Pages
-
PKS15-2USB
3 Pages
-
USB 6 Port Charger
1 Pages
-
USB 10 Port Charger
1 Pages
-
USB 10 20 Port USB Hub
1 Pages
-
MBC-100 Series
5 Pages
-
MDC060 Single Output Series
5 Pages
-
PLV120-USB
1 Pages
-
EST150
4 Pages
-
ES150 Series
6 Pages
-
PMP45-60 Series
3 Pages
-
TPM Series
1 Pages
-
240S Series
2 Pages
-
SM1500 Series
6 Pages
-
PAE800 Series
6 Pages
-
HSEUIreg07201 Series
9 Pages
-
HSEUreg07201 Series
5 Pages
-
MP Series
10 Pages
-
C(AC) Series
8 Pages
-
PAK3000 Series
6 Pages
-
PPS40LB Series
3 Pages
-
JB301-JB301D Series
5 Pages
-
PP150-PP500 Series
6 Pages
-
PAK75-PAK200 Series
3 Pages
-
PSO100-PSU100 Series
3 Pages
-
PSO80-PSU80 Series
3 Pages
-
CFM40-60 Series
2 Pages
-
MHP40-100 Series
4 Pages
-
CI-I-IT-IV-SS (AC) Series
4 Pages
-
CFM40-60
2 Pages
-
TOL series
1 Pages
-
TOF series
1 Pages
-
PA 150 series
2 Pages
-
AHP200 series
2 Pages
-
PPS40 Series
3 Pages
-
CFM20 Series
2 Pages
-
CFM10/15 Series
2 Pages
-
Inverter Series
4 Pages
-
DC-DC Converters
1 Pages
-
Desk Top Power Supplies
2 Pages
-
Plug Top Power Adaptors
1 Pages
-
High Density PFC Module
2 Pages
-
DC-AC Inverters
1 Pages
-
Lead Acid Battery Chargers
2 Pages
-
AC-DC Converters
10 Pages