Catalog excerpts
Arnhem Road DELTA ELEKTRONIKA SM1500 - Series 1500 Watts DC POWER SUPPLIES Voltage range Current range • cTUVus safety approval • Designed for long life at full power • Excellent dynamic response to load changes • Protected against all overload and short circuit conditions low emission & high immunity • Low audible noise: fans are temperature controlled • Available options: High Speed Programming, Interfaces, Extra Isolation, Sequencer, Digital Encoders, Power Sink etc. • Master/Slave parallel and series operation with voltage and current sharing • Stacking is allowed, space between units is not • High power system configuration from multiple units • 19" rack mounting or for laboratory use (feet included) • Remote sensing
Open the catalog to page 1SM 15-100 Output voltage current AUTORANGING (2 ranges) max. output current / voltage Input AC single phase, 48 - 62 Hz rated voltage range rated frequency Power Derating vs input: 90 V : Pout max (W), Iin (A) 100 V : Pout max (W), Iin (A) 110 V : Pout max (W), Iin (A) power factor, 100%, 50% load internal fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) 26 V / 52 V Efficiency AC 230 V input, full load AC 115 V input, max. load Load 0 - 100% CV Line 120 - 265 V AC CV (measured on sense block) Load 0 - 100% CC Line 120 - 265 V AC CC (internal voltage sense) Ripple + noise...
Open the catalog to page 2Status outputs CC - status LIM- status OT - status PSOL - status ACF - status DCF - status CC - operation CV or CC limit Over Temperature Power Sink Overload AC - Fail DC - Fail 2) 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 ) output voltage ± 5% beyond set point with + 5V, 1 mA or relay contact Remote ShutDown contact at rear panel, see photo of rear panel on page 1-6 Voltage meter, Ampere meter, AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote-ShutDown, Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV- and CC- mode Indicators...
Open the catalog to page 3Insulation 1 input / output creepage / clearance input / case output / case Power Supply Standard EN 61204-3, Emission: residential, light industrial environment (CISPR22-Class B) Immunity: industrial environment Generic Emission Generic Immunity EN 61000-6-3, residential, light industrial environment (EN 55022 B) EN 61000-6-2, industrial environment − 20 to + 50 °C derate output to 75% at 60 °C Operating Temperature at full load Storage temperature Output shuts down in case of insufficient cooling Thermal protection MTBF Hold-Up time Vout = 100%, Iout = 100% Vout = 85%, Iout = 100% Vout =...
Open the catalog to page 4Typical Applications Solar inverter testing, PV-Simulation Semiconductor burn-in & processing Car test systems ATE in industrial production lines • Lasers • Controlled battery (dis)charging • Component device testing • Driving PWM-controlled DC-motors • Accurate current sources • Aerospace and military equipment Available Options Two-Quadrant Output: Power sink High speed programming Increased Output Power The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be increased...
Open the catalog to page 550 Hz, unless otherwise noted. The information in this document is subject to change without notice Connections programming connector Ethernet or IEEE488 or isolated analog (all optional) - ETH user I/O, RS232, CAN, PROFI (all optional) Programming Connectors Interlock Master/Slave Output Terminals Safety Cover supplied for output (not shown)
Open the catalog to page 6All Powersolve Electronics catalogs and technical brochures
-
TMR-9WI Series
3 Pages
-
Power Banks Brochure
6 Pages
-
SM15K Series
6 Pages
-
ESB101 Series
4 Pages
-
TRACOPOWER THI3 Series
3 Pages
-
TRACOPOWER TSP-BCMU battery
8 Pages
-
EPS SERIES
1 Pages
-
PUPS22 & 44 Series
2 Pages
-
PPS60 Series
1 Pages
-
EPS SERIES 1000
1 Pages
-
PS50W Series
4 Pages
-
PS50 Series
4 Pages
-
TEQ300WIR Series
4 Pages
-
TRACO TES1V Series
3 Pages
-
TRACO TES1 Series
4 Pages
-
CFM10-15 Series
2 Pages
-
CFM05 Series
2 Pages
-
PSY300 Series
4 Pages
-
MDC080 AC
5 Pages
-
ESB00163 16A/ESB00323 32A
6 Pages
-
ESB101
4 Pages
-
ESB00351
2 Pages
-
PPT10E
2 Pages
-
PSCH30
1 Pages
-
PSCH15
1 Pages
-
p-in1504000
3 Pages
-
P-IN2902000
3 Pages
-
sm3300-interfaces
5 Pages
-
ms-adapter
1 Pages
-
al24-48
1 Pages
-
Delta catalog
15 Pages
-
sx series
4 Pages
-
s280
2 Pages
-
es300
4 Pages
-
600S
2 Pages
-
1200S
2 Pages
-
sm800
6 Pages
-
sm3000
6 Pages
-
sm3300
6 Pages
-
sm6000
6 Pages
-
5u series
2 Pages
-
PKS06-USB
2 Pages
-
PKS11-USB
3 Pages
-
PKS15-2USB
3 Pages
-
USB 6 Port Charger
1 Pages
-
USB 10 Port Charger
1 Pages
-
USB 10 20 Port USB Hub
1 Pages
-
MBC-100 Series
5 Pages
-
MDC060 Single Output Series
5 Pages
-
PLV120-USB
1 Pages
-
EST150
4 Pages
-
ES150 Series
6 Pages
-
PMP45-60 Series
3 Pages
-
TPM Series
1 Pages
-
240S Series
2 Pages
-
PAE800 Series
6 Pages
-
HSEUIreg07201 Series
9 Pages
-
HSEUreg07201 Series
5 Pages
-
MP Series
10 Pages
-
C(AC) Series
8 Pages
-
PAK3000 Series
6 Pages
-
PPS40LB Series
3 Pages
-
JB301-JB301D Series
5 Pages
-
PP150-PP500 Series
6 Pages
-
PAK75-PAK200 Series
3 Pages
-
PSO100-PSU100 Series
3 Pages
-
PSO80-PSU80 Series
3 Pages
-
CFM40-60 Series
2 Pages
-
MHP40-100 Series
4 Pages
-
CI-I-IT-IV-SS (AC) Series
4 Pages
-
CFM40-60
2 Pages
-
TOL series
1 Pages
-
TOF series
1 Pages
-
PA 150 series
2 Pages
-
AHP200 series
2 Pages
-
PPS40 Series
3 Pages
-
CFM20 Series
2 Pages
-
CFM10/15 Series
2 Pages
-
Inverter Series
4 Pages
-
DC-DC Converters
1 Pages
-
Desk Top Power Supplies
2 Pages
-
Plug Top Power Adaptors
1 Pages
-
High Density PFC Module
2 Pages
-
DC-AC Inverters
1 Pages
-
Lead Acid Battery Chargers
2 Pages
-
AC-DC Converters
10 Pages