PMP45-60 Series
3Pages

{{requestButtons}}

Catalog excerpts

PMP45-60 Series - 1

AC-DC Converter Single & Dual Outputs • Cooling by Free Air Convection • Medical Safety Approval • High Operating Temperature up to 70°C • High Efficiency, Long Life and High Reliability • Short Circuit, Overload & Over Voltage Protections Electrical Specification Input Voltage Inrush Current Leakage Current Output Voltage Output Current Voltage Adjust Range t10% single output models only Set Up, Rise Time Single output models: 500ms, 30ms at full load Dual output models: 200ms, 15ms at full load Overload Protection Single output models: 50ms at 230VAC, 13ms at 115VAC, full load Dual output models: 70ms at 230VAC, 14ms at 115VAC, full load Overvoltage Protection Operating Temp. Range Operating Humidity Storage Temp. Range Storage Humidity Above 110% of rated output power, hiccup mode, recovers automatically when fault removed 115-140% rated output voltage, latch off mode -20°C to +70°C with derating, see curves Safety Standards 10-500Hz, 2G 10min/1 cycle, period for60min each along X, Y, Z axes Certified UL/cUL (ANSI/AAMI ES 60601-1; CAN/CSA-C22.2 No.60601-1); NFPA99 Certified TUV (EN60601-1; IEC60601-1); MOPP approval_ Withstand Voltage Isolation Resistance l/P-O/P: 4KVAC, l/P-FG: 1.8KVAC, O/P-FG: 1.5KVAC Harmonic Current Natural convection 1. All parameters NOT specifically mentioned are measured at 230VAC input, rated load and 25°C ambient temperature 2. Ripple and noise are measured at 20MHz bandwidth by using a 12" twisted pair wire terminated with a 0.1 uF & 47uF capacitors across the output 3. Tolerance: includes set up tolerance, line regulation and load regulation 4. Line regulation is measured from low line to high line at rated load 5. load regulation is measured from 0% to 100% rated load 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC Directives 7. Length of set up time is measured at first cold start. Turning the power supply ON/OFF very quickly may result in an increase of set up time. Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Open the catalog to page 1
PMP45-60 Series - 2

Output Voltage and Current Ratings Peak power rating for 10 sees, only Mechanical & Connection Details Single Output Models Dual Output Models Pin Function Housing Terminal Live or equivalent or equivalent Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Open the catalog to page 2
PMP45-60 Series - 3

AC-DC Converter Derating Curves Single Output Models Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Open the catalog to page 3

All Powersolve Electronics catalogs and technical brochures

  1. PSCH30

    1 Pages

  2. SM15K Series

    6 Pages

  3. EPS SERIES

    1 Pages

  4. PPS60 Series

    1 Pages

  5. PS50W Series

    4 Pages

  6. PS50 Series

    4 Pages

  7. CFM05 Series

    2 Pages

  8. MDC080 AC

    5 Pages

  9. ESB101

    4 Pages

  10. ESB00351

    2 Pages

  11. PPT10E

    2 Pages

  12. PSCH30

    1 Pages

  13. PSCH15

    1 Pages

  14. p-in1504000

    3 Pages

  15. P-IN2902000

    3 Pages

  16. ms-adapter

    1 Pages

  17. al24-48

    1 Pages

  18. Delta catalog

    15 Pages

  19. sx series

    4 Pages

  20. s280

    2 Pages

  21. es300

    4 Pages

  22. 600S

    2 Pages

  23. 1200S

    2 Pages

  24. sm800

    6 Pages

  25. sm3000

    6 Pages

  26. sm3300

    6 Pages

  27. sm6000

    6 Pages

  28. 5u series

    2 Pages

  29. PKS06-USB

    2 Pages

  30. PKS11-USB

    3 Pages

  31. PKS15-2USB

    3 Pages

  32. PLV120-USB

    1 Pages

  33. EST150

    4 Pages

  34. ES150 Series

    6 Pages

  35. TPM Series

    1 Pages

  36. 240S Series

    2 Pages

  37. MP Series

    10 Pages

  38. C(AC) Series

    8 Pages

  39. CFM40-60

    2 Pages

  40. TOL series

    1 Pages

  41. TOF series

    1 Pages

  42. PPS40 Series

    3 Pages

  43. CFM20 Series

    2 Pages