PAE800 Series

PAE800 Series

PAE800 Series

Product catalog summary

Document Overview

This document appears to be a technical manual or datasheet related to Powersolve Electronics Ltd.'s AC-DC converters. It includes information on product functions, programming inputs, de-rating curves, remote ON/OFF control, Power OK signals, and installation instructions.

Main Sections and Summaries

1. Product Identification and Contact Information

The document repeatedly lists the company name, address (8A Arnhem Road, Newbury, RG14 5RU, England), telephone, fax, email, and website. This information is critical for customer support and inquiries.

2. AC-DC Converter Functions

This section outlines key functional features of the AC-DC converters, including:

  • Remote ON/OFF: Allows external control to switch the power supply on or off remotely.
  • Power OK Signal: Provides a status signal indicating whether the power supply output is within specified parameters.

3. Programming Input and De-rating Curve

The document references programming inputs, which likely allow adjustment of output voltage or current parameters. The de-rating curve is mentioned, which is essential for understanding how the converter's output power capability decreases under certain conditions such as elevated temperature or reduced input voltage.

4. Installation Instructions

Installation guidelines are included to ensure proper setup and safe operation of the AC-DC converters. Although detailed steps are not visible, this section typically covers mechanical mounting, electrical connections, ventilation requirements, and safety precautions.

Critical Information and Best Practices

  • Contact Details: Always use the provided contact information for technical support or sales inquiries.
  • Remote Control: Utilize the remote ON/OFF feature to integrate the power supply into automated systems safely.
  • Power OK Signal: Monitor this signal to ensure reliable operation and to detect faults promptly.
  • De-rating: Follow the de-rating curve to avoid operating the converter beyond its safe limits, which can prevent overheating and prolong device life.
  • Installation: Adhere strictly to installation instructions to maintain compliance with safety standards and ensure optimal performance.

Summary of Visual Data

The document references a de-rating curve, which is a graphical representation showing how the maximum output power decreases with changes in environmental or operational conditions. This curve is vital for system designers to size the power supply correctly.

Other diagrams or tables are not clearly extractable from the provided text but are likely present in the original document to illustrate wiring, pin configurations, or performance characteristics.

Limitations and Recommendations

Due to the corrupted or unreadable nature of much of the text, detailed technical specifications, exact parameter values, and procedural steps are not fully accessible. Users should consult the original, complete document or contact Powersolve Electronics Ltd. directly for comprehensive technical data and support.

See more

Catalog excerpts

PAE800 Series-1

Single Output • Universal AC Input with active PFC • Programmable Output Voltage (0%-105%) • Programmable Output Current (0%-105%) • 1U profile, High Power Density • Forced current sharing for parallel operation • Power OK signal (Power good, logic low) • Remote ON/OFF, Remote Sense function • Constant Current Limiting • Built-in l2C Serial Data Bus Electrical Specification Input Voltage Power Factor Inrush Current 90-264VACfull range, 47-63Hz/ 127-370VDC Below 100VAC, derate load linearly to 90% at 90VAC Leakage Current Output Voltage Output Current Voltage Tolerance Voltage Adjust Range Overload Protection ±5.0% typical adjustment by potentiometer >105% of rated output power. Protection type: Constant current limiting Overvoltage Protection Variable OVP, 125% ±7% of Vout. Output latches off, recycle AC input to recover or inhibit Over Temperature Protection Shuts down output, recovers automatically (85°C ±5°C detect on heatsink on secondary side) Auxiliary Power Remote ON/OFF Control +5V/0.5A or +8V/0.3A auxiliary output selected by user External switch or NPN transistor to turn on/off Open drain signal low when PSU turns on. Max. sink current 20mA, max drain voltage 40V Adjustment of output voltage between 0-105% of rated output Output Voltage Programming Output Current Programming Adjustment of output current between 0-105% of rated output Operating Temperature Range Operating Humidity -20°C to +60°C Above 50°C, derate linearly to 60% load at 60°C Storage Temperature Range Storage Humidity Temperature Coefficient Safety Standards Withstand Voltage Isolation Resistance l/P-O/P: 3KVAC, l/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC l/P-O/P, l/P-FG, O/P-FG: 100MQ/500VDC Harmonic Current Internal fan controlled by power rating & temperature, allow 50mm clearance at each end for airflow 1. All parameters NOT specifically mentioned are measured at 230Vac input, rated load and 25°C ambient temperature 2. Ripple and noise are measured at 20MHz bandwidth by using a 12" twisted pair wire terminated with a 0.1 uF ceramic & 47uF electrolytic capacitors across the output 3. Derating is required at low input voltages. Below 100Vac, derate linearly to 90% load at 90Vac 4. When parallel connected, only one unit may operate if the total output load is less than 5% of rated load 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC Directives Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

 Open the catalog to page 1
PAE800 Series-2

AC-DC Converter Output Voltage and Current Ratings Mechanical & Connection Details Function Description of CN2, Control Connector Serial Data used in the I2C interface Serial Data used in the I2C interface Inhibit ON/OFF - Parallel operation current share Remote Sense - Negative Output Voltage Positive Output Voltage Mating Housing Power OK (Local mode) Power OK (Remote mode) Slow Blink Power Standby Fast Blink Over Voltage Protection (OVP) Over Load Protection (OLP) Slow Blink Intermittent Blink Interlace Blink Over Temperature Protection (OTP) Power Failure Powersolve Electronics Ltd. 8A Arnhem...

 Open the catalog to page 2
PAE800 Series-3

AC-DC Conver De-ratinq Curve Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

 Open the catalog to page 3
PAE800 Series-4

AC-DC Converter Remote ON/OFF (A) Using internal 5V auxiliary source (C) Using external voltage source Internal Circuit Place an additional capacitor to have a better performance of auxiliary power operation. *The grounding of "AUX" power should be connected to "GND" port. If" V-" is connected as Grounding, make sure toshorttheGND Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

 Open the catalog to page 4
PAE800 Series-5

AC-DC Converter Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

 Open the catalog to page 5
PAE800 Series-6

AC-DC Converter Installation Instructions 1-1 Recommended standard mounting methods: 2-1 Thenaareventilatng holes on the franland backside panels. ■JL: ;iiiL aUslruel: allow 50mm at least for air flow. 2-2The Maximum allowable penetration of screw is 4mm. Incomplete threading, should out he penetrated. 2-A Recom mended the torque of mounting screw: More than 50mm More than 50mm Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

 Open the catalog to page 6

All Powersolve Electronics catalogs and technical brochures

  1. SM15K Series

    6  Pages

  2. ESB101 Series

    4  Pages

  3. EPS SERIES

    1  Page

  4. PPS60 Series

    1  Page

  5. PS50W Series

    4  Pages

  6. PS50 Series

    4  Pages

  7. CFM05 Series

    2  Pages

  8. PSY300 Series

    4  Pages

  9. MDC080 AC

    5  Pages

  10. ESB101

    4  Pages

  11. ESB00351

    2  Pages

  12. PPT10E

    2  Pages

  13. PSCH30

    1  Page

  14. PSCH15

    1  Page

  15. p-in1504000

    3  Pages

  16. P-IN2902000

    3  Pages

  17. ms-adapter

    1  Page

  18. al24-48

    1  Page

  19. Delta catalog

    15  Pages

  20. sx series

    4  Pages

  21. s280

    2  Pages

  22. es300

    4  Pages

  23. 600S

    2  Pages

  24. 1200S

    2  Pages

  25. sm800

    6  Pages

  26. sm3000

    6  Pages

  27. sm3300

    6  Pages

  28. sm6000

    6  Pages

  29. 5u series

    2  Pages

  30. PKS06-USB

    2  Pages

  31. PKS11-USB

    3  Pages

  32. PKS15-2USB

    3  Pages

  33. PLV120-USB

    1  Page

  34. EST150

    4  Pages

  35. ES150 Series

    6  Pages

  36. TPM Series

    1  Page

  37. 240S Series

    2  Pages

  38. SM1500 Series

    6  Pages

  39. MP Series

    10  Pages

  40. C(AC) Series

    8  Pages

  41. CFM40-60

    2  Pages

  42. TOL series

    1  Page

  43. TOF series

    1  Page

  44. PA 150 series

    2  Pages

  45. AHP200 series

    2  Pages

  46. PPS40 Series

    3  Pages

  47. CFM20 Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.