Overview: The document provides a detailed technical specification and operational guide for the ESB series inrush current limiters, designed for 3-phase 200/400/500Vac networks. These devices are suitable for inductive and capacitive loads, offering protection against high inrush currents in applications such as LED systems and automation.
Specifications: The ESB models are available in 16A and 32A versions, with an operating temperature range of -40°C to +70°C. They feature a peak/RMS value limiter, integrated phase control circuit, and a built-in temperature control circuit. The devices are housed in IP20-rated enclosures and are designed for DIN TS35mm rail mounting.
Technical Data: The document includes a comprehensive technical data table detailing input ranges, nominal voltages, ambient temperatures, derating factors, peak and RMS current limits, capacitive load capacities, and more. The ESB models are self-powered and consume approximately 7W during nominal operation.
Field Applications: The ESB limiters allow for increased load connections to pre-installed circuit breakers without tripping, reducing installation costs and enabling the use of smaller, faster circuit breakers. They are particularly beneficial in sensitive AC networks like traffic control systems and street lighting.
Integrated Phase Control: Each phase is controlled and monitored separately, with error signals provided for each phase. This allows for detailed monitoring and error detection in complex systems.
Operation and Safety: The document outlines the operation of the ESB with SPC to safeguard against AC failures, including phase loss and asymmetry monitoring. Safety instructions emphasize the importance of proper installation and the risks of operating without protective earth or under damp conditions.
Adjustments and Safety Tests: The Ton and Toff times can be adjusted, with factory settings at 150ms and 100ms, respectively. Safety tests are conducted by the manufacturer, and field tests should follow specific guidelines to ensure safety.
See more

Catalog excerpts

ESB00163 16A/ESB00323 32A-1

Inrush Current Limiter, Inrush Protector, 3-phase 200/400/500Vac For inductive & capacitive loads, 16A/32A -40°C...+70°C Short Specification:  Peak- / RMS Value Limiter  Integrated Phase Control Circuit  200/400/500Vac 3PH 16A/32A nominal Voltage  DIN TS35mm Rail  Federzugklemmen 0,5...16mm²  Integrated Bypass-Relay  Capacitive Load 2.000uF  Built-In Temperature Control Circuit  IP20 Housing The ESB is a budget-priced inrush peak current limiter for high loads in LEDapplications, complex automation systems and in the machine building. The ESB offers high recommended and interference free operation with both, the inductive and the capacitive load. It is simple to integrate into existing equipment. The ESB is selfpowering and does not require an external power supply. Integrated Phase Controller No simple NTC-Version! A Camtec-ESB allows effective reduction of cabling cross sections. It allows using quicker circuit breakers. The ESB prevents from tripping the circuit breakers by high inrush.

 Open the catalog to page 1
ESB00163 16A/ESB00323 32A-2

Limiting ±6% R.M.S Current Limiting ±6% Allowed Capacitive Load (max.) Limiting Time (Ton Power On) Release Time (Toff Low Voltage) Limiting Interval [Tinterval for AC cont.) Smallest advisable Circuit Breaker at 30°C Line Frequency AC Continous Current Power Supply Power Consumption Limiting Cycles Internal Protection Cooling Operation Temp. Storage Temp. EMI EMS Safety Norms Safety Class II MTBF Calculation MTTF Calculation Humidity Pollution Degree Environmental Altitude max. Dimension (BxHxT) Housing Parameters DIN-Rail Weight Connections self-powered typ. 7W (constant @ nominal operation) 1...

 Open the catalog to page 2
ESB00163 16A/ESB00323 32A-3

delay control Phase detector Phase failure Power Input Field Applications: The ESB limiter allows connecting much more loads (e.g. LED-power supply / LED-driver) to a pre-installed circuit breaker CB. The ESB definitely avoids that the CB can be tripped. This occurs independently from the objective initial current. The result is that the number of A.C. branch lines and the pre-installed CB can be reduced dramatically. Installation cost exhibit a sustained decline. Alternatively the cross section of the branch lines can be reduced when using smaller and faster responding circuit breakers. The...

 Open the catalog to page 3
ESB00163 16A/ESB00323 32A-4

The signals "Phase-Error" and "Asymmetry-Error" can be used to trigger an external contactor. The installed load will be disconnected if an error occurs. As soon as the error recovers the installed load will be reconnected to the AC. (find attached pictures „Phase-Loss &-sequence“ and „Asymmetry, Over-/Low Voltage“. The contactor is always named K2.) Phase Loss & Sequence In case of phase loss relay 4 opens after a delay time of 30ms. Synchronistic the relay of the appropriate phase opens, too and its green LED extinguishes. When the phase sequence is incorrect, relay 4 opens after a delay time...

 Open the catalog to page 4
ESB00163 16A/ESB00323 32A-5

Phase fail Sequence, Voltage and Asymmetry are o.k.: No Failure: All LEDs of L1, L2, L3 light green, all relays ore closed and all red Error LED are off Assymetry in AC line 4 Wire Systems (no N wire): Dissimilar phase load exists, when one phase is overloaded in comparison to the other phases of the 4 Wire System. Sequence Monitoring: Failure Relay4 (Phase Error) opens after 30ms delay time and its error LED lights red Phase Loss: Failure Relay4 (Phase Error) opens after 30ms delay time and its error LED lights red, belonging phase LEDs are off and its relays are open Phase-voltage correct Asymmetry...

 Open the catalog to page 5
ESB00163 16A/ESB00323 32A-6

The Ton-time (limiting period) and the Toff-time (response time to arm the circuit after a phase lost or voltage drop) can be adjusted by the owner. The factory settings are Ton=150ms and Toff=100ms. Note: the adjusting range is non-linear. Safety Tests: Test Type and Factory Tests are executed by the manufacturer. Do not repeat the tests in the field. To arrange the field test remain to the following rules: a) Use approriate test equipment which apply the voltage with a slow ramp b) For every Test L1, L2, L3 at the input and at the output must be connected, Earth must be connected c) Use...

 Open the catalog to page 6

All Powersolve Electronics catalogs and technical brochures

  1. SM15K Series

    6  Pages

  2. ESB101 Series

    4  Pages

  3. EPS SERIES

    1  Page

  4. PPS60 Series

    1  Page

  5. PS50W Series

    4  Pages

  6. PS50 Series

    4  Pages

  7. CFM05 Series

    2  Pages

  8. PSY300 Series

    4  Pages

  9. MDC080 AC

    5  Pages

  10. ESB101

    4  Pages

  11. ESB00351

    2  Pages

  12. PPT10E

    2  Pages

  13. PSCH30

    1  Page

  14. PSCH15

    1  Page

  15. p-in1504000

    3  Pages

  16. P-IN2902000

    3  Pages

  17. ms-adapter

    1  Page

  18. al24-48

    1  Page

  19. Delta catalog

    15  Pages

  20. sx series

    4  Pages

  21. s280

    2  Pages

  22. es300

    4  Pages

  23. 600S

    2  Pages

  24. 1200S

    2  Pages

  25. sm800

    6  Pages

  26. sm3000

    6  Pages

  27. sm3300

    6  Pages

  28. sm6000

    6  Pages

  29. 5u series

    2  Pages

  30. PKS06-USB

    2  Pages

  31. PKS11-USB

    3  Pages

  32. PKS15-2USB

    3  Pages

  33. PLV120-USB

    1  Page

  34. EST150

    4  Pages

  35. ES150 Series

    6  Pages

  36. TPM Series

    1  Page

  37. 240S Series

    2  Pages

  38. SM1500 Series

    6  Pages

  39. PAE800 Series

    6  Pages

  40. MP Series

    10  Pages

  41. C(AC) Series

    8  Pages

  42. CFM40-60

    2  Pages

  43. TOL series

    1  Page

  44. TOF series

    1  Page

  45. PA 150 series

    2  Pages

  46. AHP200 series

    2  Pages

  47. PPS40 Series

    3  Pages

  48. CFM20 Series

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.