AHP200 series
2Pages

{{requestButtons}}

Catalog excerpts

AHP200 series - 1

AC-DC Converters www.powersolve.co.uk AHP 200 Series Up to 212 Watts Output Features • • • • • • • • 3.00” x 5.00” x 1.34” High Power Density - 10.6 W/in3 Up to 90% Efficiency 5 V Standby & 12 V Fan Outputs Active Current Share Remote On/Off Power Good Signal 48 VDC Input Versions Available (DAHP200 Series) Electrical Specification INPUT Input Voltage 90-264 VAC Input Frequency 47-63 Hz Input Current 2.2 A max at 115 VAC, 1.1 A max at 230 VAC Inrush Current 60 A max at 230 VAC, cold start at +25 ºC Power Factor >0.9 typical Earth Leakage Current 1.1 mA max 264 VAC/50 Hz, 500 µA typical at 230 VAC/50 Hz, 290 µA typical at 115 VAC/60 Hz OUTPUT Output Voltage See table Output Voltage Trim No user adjustment available Initial Set Accuracy V1: ±1%, V2: ±5%, V3: ±3% Minimum Load No minimum load required Start Up Delay <3 s maximum Start Up Rise Time 20 ms maximum Hold Up Time 16 ms minimum Drift <±0.2% after 20 min warm up Line Regulation V1: ±0.5%, V2: ±2%, V3: ±0.5% Load Regulation V1: ±1% 0-100% load, V2: ±1% 10-100% load, V3: ±1% 0-100% load Cross Regulation V2: ±10% 10-100% load change on V1 Over/Undershoot <2% max at turn on/off for 12 V models, <5% for 24 V & 48 V models Transient Response <4% max deviation for a 25-75-25% load step. Output V1 returns to within 1% in 500 µs Ripple & Noise V1 & V3: 1%, V2: 2% pk-pk, 20 MHz BW Overvoltage Protection 115-140% Vnom, recycle input to reset (output 1 only) Overtemperature Primary & secondary protection with Protection auto recovery Overload Protection 110-140%, auto recovery output 1 Short Circuit Protection Trip and restart (Hiccup mode) Temperature Coefficient 0.05%/ºC Remote On/Off Uncommitted isolated opto-coupler diode, powered diode inhibits the supply Current Share Up to 3 supplies to share within 10%, derate total output to 90% GENERAL Efficiency 88% typical Isolation 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground Switching Frequency 80 kHz typical for PFC, 100 kHz typical for main converter Power Density 10.6 W/In3 Signals Combined PF & DC OK - Open collector referenced to output 0 V, transistor normally off when AC & output good. PF provides >5 ms warning of loss of output from AC failure. DC OK provides warning of DC output failure. MTBF 400 kHrs per MIL-HDBK-217F typical ENVIRONMENTAL Operating Temperature -10 ºC to +70 ºC, derate linearly from +50 °C at 2.5%/°C to 50% at +70 °C Cooling 12 CFM airflow required (see thermal considerations) Operating Humidity 5-95% RH, non-condensing Storage Temperature -20 ºC to +85 ºC Operating Altitude 3000 m Shock 30 g pk, half sine 6 axes Vibration 2 g, 5 Hz to 500 Hz, 3 axes EMC & SAFETY Emissions EN55022, level B conducted, EN55022, level A radiated Harmonic Currents EN61000-3-2, class A Voltage Flicker EN61000-3-3 EFT/Burst EN61000-4-4, level 3 Perf Criteria A Surge EN61000-4-5, level 3 Perf Criteria A Conducted Immunity EN61000-4-6, 10 Vrms, Perf Criteria A Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals CB report IEC60950-1:2001, CSA 22.2 No. 60950-1-03, TUV EN60950-1/A11:2004, CE Mark (LVD), CCC pending, contact sales Powe rsolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk

Open the catalog to page 1
AHP200 series - 2

AC-DC Converters www.powersolve.co.uk MODELS AND RATINGS MODEL NUMBER AHP200-12 AHP200-24 AHP200-48 MAX OUTPUT POWER (12 CFM AIR FLOW) 212 W 212 W 205 W MECHANICAL DETAILS OUPUT CURRENT (12 CFM AIRFLOW) 16.7 A 8.3 A 4.0 A SCREW TYPE SAFETY EARTH - 4.8 mm Faston Notes: 1. All dimensions in inches (mm). 2. Units supplied with screw terminal (CN2) as standard. For faston type, add suffix ‘-F’ to the part number. 3. All 4 mounting positions should be connected to safety earth. 4. The air flow needs to be directed through the power supply within the end application. +V2 V2 Return V2 Return ROF...

Open the catalog to page 2

All Powersolve Electronics catalogs and technical brochures

  1. PSCH30

    1 Pages

  2. SM15K Series

    6 Pages

  3. EPS SERIES

    1 Pages

  4. PPS60 Series

    1 Pages

  5. PS50W Series

    4 Pages

  6. PS50 Series

    4 Pages

  7. CFM05 Series

    2 Pages

  8. MDC080 AC

    5 Pages

  9. ESB101

    4 Pages

  10. ESB00351

    2 Pages

  11. PPT10E

    2 Pages

  12. PSCH30

    1 Pages

  13. PSCH15

    1 Pages

  14. p-in1504000

    3 Pages

  15. P-IN2902000

    3 Pages

  16. ms-adapter

    1 Pages

  17. al24-48

    1 Pages

  18. Delta catalog

    15 Pages

  19. sx series

    4 Pages

  20. s280

    2 Pages

  21. es300

    4 Pages

  22. 600S

    2 Pages

  23. 1200S

    2 Pages

  24. sm800

    6 Pages

  25. sm3000

    6 Pages

  26. sm3300

    6 Pages

  27. sm6000

    6 Pages

  28. 5u series

    2 Pages

  29. PKS06-USB

    2 Pages

  30. PKS11-USB

    3 Pages

  31. PKS15-2USB

    3 Pages

  32. PLV120-USB

    1 Pages

  33. EST150

    4 Pages

  34. ES150 Series

    6 Pages

  35. TPM Series

    1 Pages

  36. 240S Series

    2 Pages

  37. MP Series

    10 Pages

  38. C(AC) Series

    8 Pages

  39. CFM40-60

    2 Pages

  40. TOL series

    1 Pages

  41. TOF series

    1 Pages

  42. PPS40 Series

    3 Pages

  43. CFM20 Series

    2 Pages