240S Series
2Pages

{{requestButtons}}

Catalog excerpts

240S Series - 1

Unit 8A Arnhem Road Newbury. RG14 5RU Voltage range Current range Efficiency Regulation Load 0 - 100% Line 198 - 265 V AC Ripple + noise (BW = 20 MHz) Temp. coefficient Stability during 8 hrs Output impedance Recovery time Insulation Input / output Input / case Output / case Hold-up time Ambient temperature Operating Storage Series operation Parallel operation Alarm circuit Current limit OVL MTBF Dimensions and weight : Adjustable 12 - 30 V with a screwdriver or analog programmable by 2 - 5 V. Factory set at 24 V. : AC 195 - 265 V 48 - 62 Hz 1.8 Arms 100 - 132 V 48 - 62 Hz 3.2 Arms For DC or operation at 400 Hz contact factory Fuse 4 A T at 230 V, 6.3 A T at 110 V : EN 60950 EN 61010 SELV / PELV EN 61204-3 Low Voltage DC Power Supplies EN 61000-6-3 (EN 55022B) Generic Emissions EN 61000-6-2 Generic Immunity : 87% at 240 W output (max. heat dissipation 36 W) : 50 mV (10 mV when using sense points) : 10 mV : 5 mVrms, 15 mV p-p : 5.10–5 per °C : 3.10–4 (after 1 hr warm up) : 0.1 Ohm up to 100 kHz : 200 µs after 50 - 100% load step : 3750 Vrms (1 min.) : 2500 Vrms (1 min.) : 500 V DC : 20 ms (24 V / 10 A, 230 V AC input) Euro Cassette 6 HE high, 14 TE wide (front panel 16 TE). Is supplied incl. H15 mating connector (faston version), CL15 and 2 pcs H155. : –10 to +50 °C. Above 50 °C derate current linearly to 20% at 80 °C. : –40 to +85 °C. : Up to 500 V total voltage : At 90% of max. current (Internal current limit switch at low). The extra positive output terminal, via a built-in Schottky diode, separates the output circuits when units are operated in parallel. : A relay contact changes over when the output drops 10% below the set value. Gold contact, rating max. 100 mA / 30 V. : Constant power limit from 30 to 22 V, constant current below 22 V. Current limit protects against continuous overload and short circuit. : Limits the maximum output voltage at about 33 V. : 1 000 000 hrs : Height 240 mm Width 71 mm Depth 156 mm Weight 2.0 kg

Open the catalog to page 1
240S Series - 2

Remote sensing Remote progr. external potmeter :The 240S24 should be mounted vertically for optimal cooling. When mounted horizontally, put internal current limit switch at low and keep the ambient temp, below 40 °C. :The sense points (pin 8 and 10) are internally connected to + and - output (pin 6 and pin 12), but these links can be removed when remote sensing is required. The voltage drop across the leads plus the load can never exceed the supply maximum output rating. For example at 24 V 8 A it is possible to compensate 6 V (3 V per lead) because the :2 - 5 V between pin 14 and 10 gives...

Open the catalog to page 2

All Powersolve Electronics catalogs and technical brochures

  1. PSCH30

    1 Pages

  2. SM15K Series

    6 Pages

  3. EPS SERIES

    1 Pages

  4. PPS60 Series

    1 Pages

  5. PS50W Series

    4 Pages

  6. PS50 Series

    4 Pages

  7. CFM05 Series

    2 Pages

  8. MDC080 AC

    5 Pages

  9. ESB101

    4 Pages

  10. ESB00351

    2 Pages

  11. PPT10E

    2 Pages

  12. PSCH30

    1 Pages

  13. PSCH15

    1 Pages

  14. p-in1504000

    3 Pages

  15. P-IN2902000

    3 Pages

  16. ms-adapter

    1 Pages

  17. al24-48

    1 Pages

  18. Delta catalog

    15 Pages

  19. sx series

    4 Pages

  20. s280

    2 Pages

  21. es300

    4 Pages

  22. 600S

    2 Pages

  23. 1200S

    2 Pages

  24. sm800

    6 Pages

  25. sm3000

    6 Pages

  26. sm3300

    6 Pages

  27. sm6000

    6 Pages

  28. 5u series

    2 Pages

  29. PKS06-USB

    2 Pages

  30. PKS11-USB

    3 Pages

  31. PKS15-2USB

    3 Pages

  32. PLV120-USB

    1 Pages

  33. EST150

    4 Pages

  34. ES150 Series

    6 Pages

  35. TPM Series

    1 Pages

  36. MP Series

    10 Pages

  37. C(AC) Series

    8 Pages

  38. CFM40-60

    2 Pages

  39. TOL series

    1 Pages

  40. TOF series

    1 Pages

  41. PPS40 Series

    3 Pages

  42. CFM20 Series

    2 Pages