1200S
2Pages

{{requestButtons}}

Catalog excerpts

1200S - 1

Unit 8A Arnhem Road Newbury. RG14 5RU SWITCHED MODE DC POWER SUPPLY Features : • Very high reliability, MTBF 500.000 hrs • Natural convection cooling • High efficiency 89% • Under-voltage alarm contact • Low output ripple, 7 mV rms • No RFI problems, RFI filters in output and input • Build-in diode for redundant parallel operating • Analog programmable • Short circuit protected • Low inrush current Specifications : • Input voltage • Insulation Input / output Input / case Output / case • Inrush current • Line disortion • Power factor • Safety • EMC : AC 198-264 V 48-62 Hz 8.2 Arms fuse 15 A T, crest factor 2.2 : AC 99-132 V 48-62 Hz 16.4 Arms fuse 25 A T : DC contact factory : 3750 V rms (1min) : 2500 V rms (1min) : 500 V DC : Limited by 39 Ohm (shorted after startup) : Kept low by large low frequency choke input : 0.72 at 230 V AC input and full load. : EN 60950 / EN 61010 SELV / PELV ( for 1200 S 24 only ) : EN 61204-3 Power Supply Standard : EN 61000-6-3 Emission (EN 55022B) : EN 61000-6-2 Immunity • Output voltage • Efficiency • Temp. coeff. • Stability • Regulation Load 0 - 100% Line 198 -264 V • Ripple + noise (BW = 20 MHz) • Output imp. • Recovery time • Hold-up time • VDE0160 impulse test • Parallel operation : Input with stands non periodic impulse 2.3 Ûn 0.3 ms of VDE0160 class 1 : For safe parallel operation put current limit switch at 'LO' ( max.1100 W) • Series operation • Redundant parallel operation : Screwdriver adjustable with 10 turn potmeter at the rear side. Also programmable by 2-5 V : 89% at 230 V AC input. : 5.10-5 per C : 3.10-4 during 8 hrs under constant conditions, after 1 hr warm up. : Better than 10 mV : Better than 5 mV : Max. 7 mV rms, 20 mV pp : Less than 0.05 Ohm up to100kHz : 0.3 milliseconds to recover within 100 mV after 50 to 100% load step. Max deviation 300 mV. : 15 ms at 115 or 230 V AC input and full load. 30 ms at half load. : Up to 500 V total Voltage. Use R+ connection via build-in Schottky diode to separate the out

Open the catalog to page 1
1200S - 2

• Under voltage alarm contact : changes over when output voltage drops to 10% below the set value. Contact rating 100 mA / 30 V. • Remote control : Is possible with a 10 KΩ potmeter. • Remote programming : Output voltage is programmable with 2-5 V, corresponding with 12-30 V (24-60 V). Programming speed is 100 ms from 12-30 V (24-60 V) at max. current. Programming input is not isolated ( connected to - output) • Remote sensing : max. 3 V per load lead. however the sum of voltage across load + leads cannot exceed 30 V (60 V) With parallel operation remote sensing is not recommended. • Remote...

Open the catalog to page 2

All Powersolve Electronics catalogs and technical brochures

  1. SM15K Series

    6 Pages

  2. EPS SERIES

    1 Pages

  3. PPS60 Series

    1 Pages

  4. PS50W Series

    4 Pages

  5. PS50 Series

    4 Pages

  6. CFM05 Series

    2 Pages

  7. MDC080 AC

    5 Pages

  8. ESB101

    4 Pages

  9. ESB00351

    2 Pages

  10. PPT10E

    2 Pages

  11. PSCH30

    1 Pages

  12. PSCH15

    1 Pages

  13. p-in1504000

    3 Pages

  14. P-IN2902000

    3 Pages

  15. ms-adapter

    1 Pages

  16. al24-48

    1 Pages

  17. Delta catalog

    15 Pages

  18. sx series

    4 Pages

  19. s280

    2 Pages

  20. es300

    4 Pages

  21. 600S

    2 Pages

  22. sm800

    6 Pages

  23. sm3000

    6 Pages

  24. sm3300

    6 Pages

  25. sm6000

    6 Pages

  26. 5u series

    2 Pages

  27. PKS06-USB

    2 Pages

  28. PKS11-USB

    3 Pages

  29. PKS15-2USB

    3 Pages

  30. PLV120-USB

    1 Pages

  31. EST150

    4 Pages

  32. ES150 Series

    6 Pages

  33. TPM Series

    1 Pages

  34. 240S Series

    2 Pages

  35. MP Series

    10 Pages

  36. C(AC) Series

    8 Pages

  37. CFM40-60

    2 Pages

  38. TOL series

    1 Pages

  39. TOF series

    1 Pages

  40. PPS40 Series

    3 Pages

  41. CFM20 Series

    2 Pages