1. Catalogs
  2. Powerbox
  3. PT578 Series

PT578 Series
1 /2Pages

PT578 Series

PT578 Series
1 /2Pages

Catalog excerpts

PT578 Series-1

POWERBOX Marine Line PT578 Series 500W Single Output AC/DC Switch Mode Power Supply Preliminary datasheet Features DNV-GL Approved for bridge use (pending) EN60945 compliant Universal input (90 - 265Vac) Efficiency above 93% Active Power Factor Correction Adjustable output Overload and overvoltage protection Thermal overload protection Conformal coating DC OK signal and potential free contact Cooling by free air convection DIN-Rail mounting on back or side RoHS compliant Internal redundancy diode Single or parallel mode user selectable Frequency 47-63Hz, 440Hz with reduced PFC. Inrush current 30A, cold start @ 230VAC/25°C. Input fuse 10AT, internal, not user serviceable. Output Output voltage 24V, adjustable 23-29V. Temperature coefficient ±0.02%/°C. Overvoltage protection 32V. Overload protection User selectable (see table 1). Peak short circuit current 40A (<100ms). Overtemp. protection ±90°C internal temp. DC OK signalling LED on front: Green = DC OK Flashing Red = Overload Red = DC Fail Potential free contact; active closed; I < 1 A open voltage < 30V Environmental Thermal performance Operating temperature -25°C to +70°C without derating. Storage temperature -40°C to +85°C. Humidity Up to 100% condensing at all relevant temperatures. Conformal coating. Vibration DNV-GL table 7 High vibration strain, class B, General Isolation voltage 3000VAC Input/Output. Dimensions (HxWxD) 132 x 67 x 128 mm. Excluding DIN-Rail mounting device. Add 10mm for standard mounting device and EN50022 DIN-Rail. Warranty 2 years. Standards EMC Emissions EN60945 conducted & radiated. Temperature, class D -25°C to +55°C. Humidity, class B, up to 100%. Vibration, class B, ±1.6mm displ. 2-25Hz, 4g 25-100Hz. EMC Class B, bridge and open deck. Class guideline DNVGL-CG-0339, November 2015. CEEMC Directive 2014/30/EU. Low Voltage Directive is 2014/35/EU. Load regulation is specified with single/parallel DIP switch (SW3) in the OFF position. With DIP switch SW3 in the ON position the load regulation is 2% typical.

 Open the catalog to page 1
PT578 Series-2

POWERBOX Marine Line PT578 Series 500W Single Output AC/DC Switch Mode Power Supply Pin Connection DIP Switch Settings Input Connector Table 1 Output Connector Pin_Function_ 2_DC OK; Potential Free Contact 3_DC OK; Potential Free Contact X_X_OFF SINGLE OPERATION Wire Gauge_ OPTION 1: overload results in latched switch off OPTION 2: overload results in hiccup mode OPTION 3: overload results in current limit, with latched switch off short circuit protection OPTION 4: overload results in current limit, with latched switch off short circuit protection Specifications are subject to change without...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.