OFM100 Series-1

Features Ultra high power density 12.5W/sq inch Reliable front edge fly-back design with very low component count Standard 2x4 inch footprint Very low leakage current allow parallel connection for higher output power requirements Approved according to IEC/UL 60601-1 Superior EMC performance Intelligent over temperature protection Input Nominal input range 100-240VAC. Voltage range 90-264VAC Inrush current Max 50A peak, cold start. Input cable connector Recommended: Housing: Molex 6442 series 3-pin housing part No 0026034030 (locking) or 002603 3031 (non-locking). Connector terminals: 0008520112 (reel) or 0008520113 (bag), tin plating. Leakage current <75|oA. Isolation class Class I, double isolation between input and output. Isolation 4000 VAC, 1s input to output. 4000 VAC, input to ground. 100 VDC, output to ground. 10Mohm isolation prim-sec. Zero load power consumption Approx 0,3 Watts at 110 VAC input. Output Power Up to 100W, continuous at 100-240VAC input, see table. Voltage See table. Factory preset non adjustable. Ripple and noise Typ 1% p-p max (20 MHz BW). 5% at <110VAC input. Efficiency87-90% @ 230VAC full load. Hold up time 35ms at 230VAC. Line regulation 1% max full load. 5% at <100VAC input. Load regulation 2% max @ 230VAC, 10-90% load change at output terminal. Overcurrent protection Approx 125%, auto recovery. POWERBOX M OFM100 Series 100W Single Output AC/DC Medical Switch Mode Power Supply Current limiting charact. Constant current. Overtemp. protection Yes, auto recovery and output power limiting. Overvoltage protection Yes. Transient response 4ms max. Temperature coefficient Typ. 0.04%/°C of Uo. Output connector Recommended: Housing: Molex 6442 series 4-pin housing part No 0026034041 (locking) or 0026033041 (non-locking). Connector terminals: 0008520112 (reel) or 0008520113 (bag), tin plating. Environmental Operating temperature 0°C to 50°C (according to test method in IEC60601-1 and 0°C to 40°C acc to IEC60950-1). Storage temperature -40°C to +75°C. Derating Derate from 100% at 50°C linearly to 50% at +70°C. Derate to 80W output power at convection cooling. 12-15VDC versions derate to 70W at convection cooling. Cooling Convection or fan cooling. 6,6CFM (11m3/h) required for 100W continuous output. See drawing. Environmental compliance RoHS, REACH and WEEE. General Switching frequency 40-80kHz. Acoustic noise Less or equal to 30dB(A) at a distance of 0.3m and in frequency range 1Hz to 20kHz. Dimensions 51 x 102 x 32 mm (2x4 inch). MTBF 270,000 hours at 25°C ambient temperature, 50 years power on. Lifetime prediction Min 80,000 hrs at 25°C, 230VAC at 70% load. Warranty 2 years. Installation guide Available at Powerbox website.

 Open the catalog to page 1
OFM100 Series-2

POWERBOX M OFM100 Series 100W Single Output AC/DC Medical Switch Mode Power Supply Standards Safety standards Approved according to IEC60601-1 Edition 3 including deviations for Europe, US & Canada by Intertek Semko. Fulfills IEC60950-1. UL pending. Safety markings S, ETL, UL & CE Voltage fluctuations and flickerIEC61000-3-3. ESD susceptibility IEC61000-4-2, ±6kV contact discharge, ±8kV air discharge. Radiated susceptibility IEC61000-4-3, 3V/m. EFT/Burst IEC61000-4-4, ±2kV on AC port, ±1kV on signal ports. Surge IEC61000-4-5, ±2kV common mode, ±1kV differential mode. Conducted susceptibility...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.