1. Catalogs
  2. Powerbox
  3. OBP37 Series

OBP37 Series
1 /4Pages

OBP37 Series

OBP37 Series
1 /4Pages

Catalog excerpts

OBP37 Series-1

Features Operating altitude up to 5000 meters 3 x 6 inch footprint with 1.5 inch low profile 100-240 VAC input with active PFC Meet 55022 and FCC Class B Power Factor 0.98 typical 100% burn-in at full load Short-circuit protection Power Fail Detect (PFD) signal Inhibit - TTL high to disable output Compliant with RoHS requirements High Efficiency 92% typical Power consumption in standby mode less than 1 W at standby power 5 V /100 mA Output Power See table. Voltage/current See table. Ripple and noise 1% peak to peak maximum. Remote sense Compensation for cable losses up to 0.5V. Over voltage protection Set at 112-140% of its nominal output voltage. Over current protection Output protected to short circuit conditions. Temperature coefficient ±0.04%/°C max. Transient response Max excursion of 4% or better on all models, recovering to 1% of final value within 500us after a 25% step load change. Fan power 12V at 1.0 A maximum (isolated). Standby power 5 V at 2.0 A maximum or 12 V at 1.0 A max. Relative humidity 5-95% non-condensing. Derating Derate from 100% at +50°C linearly to 50% at +70°C, applicable to convection and forced-air cooling conditions. General Switching frequency 100KHz typical. Efficiency 87% minimum on all models. POWERBOX ndustrial Line 300 OBP37 Series 300W Single Output AC/DC Switch Mode Power Supply Turn on delay time 3 max at 100VAC. Line regulation ±0.5% max at full load. cold start. Withstand voltage 3,000VAC from input to output. 1,500VAC from input to ground. 500VAC from output to ground. MTBF 250,000 hours at full load at 25°C ambient, Interface Signals PFD TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to V1 output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after V1 is within regulation. Inhibit Requires an external TTL high level signal to inhibit outputs for standard models. TUV EN60950-1. EMC performance EN55011/EN55022 Class B conducted, Class B radiated. FCC Class B conducted, Class B radiated. VCCI Class B conducted, Class B radiated. EN61000-3-2 Harmonic distortion Class A and D. EN6100-4-8 Magnetic field immunity, 1A/m. EN61000-4-11 Voltage dips, 30% reduction for 500ms,

 Open the catalog to page 1
OBP37 Series-2

POWERBOX ndustrial Line 300 OBP37 Series 300W Single Output AC/DC Switch Mode Power Supply Output Min Max Current Max Current Peak Tol Ripple & 1. Suffix “A” in model numbers denotes PCB constructed form. Change suffix “A” to “B” for L-bracket form, e.g. OBP37046B. Change “B” to “C” for enclosed from with cover and fan assembly, e.g. OBP37046C. 2. 200 W without moving air or 300 W with 10 CFM forced air provided by user for “A” and “B” version, 300 W for “C” version with cover and fan assembly. 3. Standby power output 5 V at 2 A. Add suffix “-12” for standby power output 12 V at 1.0...

 Open the catalog to page 2
OBP37 Series-3

POWERBOX Industrial Line 300 OBP37 Series 300W Single Output AC/DC Switch Mode Power Supply Mechanical PCB Constructed Form Mechanical L-Bracket Form

 Open the catalog to page 3
OBP37 Series-4

POWERBOX Industrial Line 300 OBP37 Series 300W Single Output AC/DC Switch Mode Power Supply Mechanical Enclosed Form Notes: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Dinkle DT-35-B01W-03 with M3, nickel-plated screws. 4. Output connector P2 and P3: M3 x 0.5 screw connections 5. Fan connector P4: Molex header 22-04-1021 or equivalent, mating with Molex housing 22-011022 or equivalent. 6. Connectors P5: Molex header 22-04-1061 or equivalent, mating with Molex housing 22-011062 or equivalent. 7. Option output connector P7: Molex header 39-30-1180...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.