DBB600 Series
6Pages

{{requestButtons}}

Catalog excerpts

DBB600 Series - 1

Preliminary Description The DBB, very compact and low profile 600W AC/DC power supply in chassis format, incorporates input filtering, input and output protections, very robust mechanical mounting and connection, conformal coating and MIL-STD options required in most of the severe environment for industrial, defense applications. The PSU provides high reliability, high efficiency, input-to-output isolation, soft start and active very low inrush circuit, overtemperature protection, input over/undervoltage lockout. The PSU is configurable with 1 to 3 outputs in many output voltages from 3V3 to 48VDC, other outputs are even possible as semistandard versions, they are countinuously short-circuit proof. The 100°C baseplate allows operation in high temperature environment. Features 85-264 VAC input voltage ranges , PFC 1-3 isolated outputs 200*127* 40mm very low profile Industrial or ruggedizzed versions Active very low inrush current Many output configurations available Conduction cooled 100°C baseplate Safety IEC/EN 60950-1, RoHS lead-free-solder compliant Options Description MIL-STD ruggedized (-M) Meet MIL-STD 461E CE102, MIL-STD 1399-300A, MIL-STD810E shock & vibrations. No laboratory certification. -40°C operation (-T) The thermal grade of the DC/DC converters used and other components are changed to comply with low ambient temperature. Conformal coating (-V) During manufacturing process , when V option is specified, components and pcb are covered with an acrylic coating to address high level of ambiant humidity application. Heatsink (-H, -H1) -H: a 15 mm heatsink is mounted on the baseplate with longitudinal fins. -H1: a 15 mm heatsink is mounted on the baseplate with transversal fins. Electrical Input Data Operating input voltage 85-264VAC. 100-350VDC. Frequency 47Hz min, 50Hz typ, 440Hz max. Power factor 0.96 typ, 230VAC, 50Hz, Pnom. No-load input power 8W at Vin typ. Peak inrush current 1A Vin max. Input fuse A fuse mounted inside the psu protects against damages in case of a failure. Fuse type Littlefuse, 10A, 0451010.MRL. Transient protection Yes. Parallel operation Possible. POWERBOX Defense Line 600 DBB Series 600W AC/DC Conduction Cooled Redundant operation Requires external oring diodes. Hold-up time Yes. Output current limitation All outputs are protected against short circuit, automatic recovery. Thermal considerations Baseplate should not exceed 100°C. Thermal protection OTP protection, automatic restart. Overvoltage protection Incorporated on each output. Remote on/off An isolated INHIB signal disable corresponding output voltage when connected to RTN. Overvoltage adjustment 90-110%Vnom. Remote sense V1, V2, total drop <0.5V, positive line drop <0.25V. Powergood & LED Available for each output. Auxiliary bias voltage Limited to 200mA. Paralleling signal Parallel only identical outputs (voltage and power). Environmental Operating ambient temp. -20°C to +71°C, see derating (T-option -40°C). Heatsink temperature -20°C to +100°C (T-option -40°C). Storage temperature -40°C to +125°C. Damp heat MIL STD 810 Proc. 507-2. Shock MIL STD 810 Proc. 516.3 Vibrations MIL STD 810 Proc. 514-5. MTBF MTBF calculation for a specific part number has General Electric strenght Input to earch 1500Vrms. Input to output 3000Vrms. Output to earth 500Vrms. Insulation resistance >100Mohms. Case Aluminum natural. Standards Safety standards Built to meet IEC60950-1, EN60950-1. EMC Surges Built to meet EN61000-4-5, 1kV, Criteria B. 2kV, Critiera A. Electrostatic discharge Built to meet EN61000-4-2, 8000V, Critiera B. Fast transients/burst Built to meet EN61000-4-4, 4000V, Critiera B. Harmonics Built to meet EN61000-3-2. Flickers Built to meet EN61000-3-3.

Open the catalog to page 1
DBB600 Series - 2

POWERBOX Defense Line 600 DBB Series 600W AC/DC Conduction Cooled Characteristics Conditions min typ max min typ max min typ max min typ max min typ max min typ max min typ max Unit Trim range Factory set 3 3.6 4.5 5.5 10.8 13.2 13.5 16.5 21.6 26.2 25.2 30.8 43.2 51.8 V Load regulation Vin nom 1 1 0.5 0.5 0.4 0.4 0.4 % M board includes 1 M module below Output current limit...

Open the catalog to page 2
DBB600 Series - 3

POWERBOX Defense Line 600 DBB Series 600W AC/DC Conduction Cooled Block Diagram ACTIVE INRUSH CURRENT 3 x 150W Micro Module OR 2 x 300W Mini Module Maxi Module

Open the catalog to page 3
DBB600 Series - 4

POWERBOX Defense Line 600 DBB Series 600W AC/DC Conduction Cooled 4 mounting holes diameter 4.2mm

Open the catalog to page 4
DBB600 Series - 5

POWERBOX Defense Line 600 DBB Series 600W AC/DC Conduction Cooled 4 mounting holes diameter: 4.2mm

Open the catalog to page 5
DBB600 Series - 6

POWERBOX Defense Line 600 DBB Series 600W AC/DC Conduction Cooled Input screw type connector GMKDS 3/3-7.62_ Output M-board power connectors_ Output m-board power connectors_ Output M-board power connectors_ Signals Wurth 690368191472 Female Male 2*7 pins_

Open the catalog to page 6