POWERLEVEL T3 SERIES Data Center HIGHLIGHTS •• True Three Level Rectifier and Inverter Technology •• Ultra High Output Galvanic Isolation Transformer Embedded •• Robust and Reliable Design HIGHEST RELIABILITY WITH EMBEDDED ISOLATION TRANSFORMER •• PowerLevel T3 Series is a true VFI on-line double conversion, three-phase UPS system with Innovative 3 Level Technology and engineered to provide high level of energy efficiency and reliable and robust protection for most demanding industrial and medical environments. •• Three level inverter and rectifier technology and with embedded isolation transformer makes PowerLevel T3 Series one of the most reliable systems for data security and other critical applications. Power Factor POWER-SONIC EUROPE LIMITED Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: [email protected] COMPACT DESIGN •• Designed with an Integrated transformer ensuring galvanic isolation on the output for ultimate safety. •• Easy to install and service and can be integrated into harsh commercial and industrial environments. •• Compact footprint with matching battery cabinets. LOW TOTAL COST OF OWNERSHIP •• Less energy consumption thanks to high efficiency. •• Reduced energy loss. •• Reduced electricity consumption and air conditioning requirements. •• Reduction in operating cost of UPS. •• IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to lower electricity charges/costs, reduces cable, switchboard, fuse and generator sizes, thus reducing investment cost. •• Low input current total harmonic distortion (THDi) less than 3% helps to avoid supply disturbance and expensive harmonic filters. •• Small footprint and easy maintenance. 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: [email protected] (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA – EUROPE, MIDDLE EAST AND AFRICA) To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2019. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E
Open the catalog to page 1HIGH OUTPUT POWER FACTOR 1 •• Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS. •• Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation). •• No reduction in active power from 0,9 leading to 0,9 lagging. PowerLevel Output Power Factor Scheme MAXIMUM AVAILABILITY •• Parallel configuration STANDARD ELECTRICAL FEATURES •• Embedded Output Galvanic Isolation Transformer •• Dual Input •• Common Battery option •• Frontal Access for Input/Output Cabling •• Backfeed Protection •• Cold Start (Optional)...
Open the catalog to page 2Back Panel Back Panel 1. Parallel Port Terminal 2. RS232 Terminal Back Panel Back Panel 3. Optional Card Slots 517 4. DC Bus Ramping Up Button 5. Switch Port Terminal 1. Parallel 1. Parallel Port Terminal 1. Parallel Port Terminal 4. DC Bus Ramping Up Button 5. Isolation Breaker 2. RS232 Terminal2. RS232 Terminal 2. RS232 Terminal Card Slots 3. Optional Card Slots 3. Optional 4. DCOptional Card Button 4. DC Bus Ramping Up Button 3. Bus Ramping Up Slots 5. Switch 5. Switch 1. Parallel Port Terminal 2. RS232 Terminal Back Panel Back Panel 3. Optional Card Slots 4. DC Bus Ramping Up Button 5. Switch...
Open the catalog to page 3DETAILS POWERLEVEL T3 SERIES 100-120 kVA 1. RS232 Terminal 2. Optional Card Slots 3. DC Bus Ramping Up Button 4. Isolation Breaker 5. External Temperature Sensor Output Front Panel 1750 Front Panel Front Panel CORPORATE HEADQUARTERS 1. RS232 Terminal (USA AND INTERNATIONAL EXCLUDING EMEA) POWER-SONIC EUROPE LIMITED 1. RS232 Terminal 2. Optional Card Slots 3. DC Bus Ramping Up Button 4. Isolation Breaker 5. External Temperature Sensor Output Switch (EMEA –4.EUROPE, MIDDLE EAST AND AFRICA) To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published...
Open the catalog to page 4SONIC, TRUSTED BATTERY SOLUTIONS 120kW 160kVA 200kVA 160kW 200kW Voltage Range Power Factor Frequency Range Total Harmonic Distortion (THDi) 380/400/415 VAC 3 Phase +N (Optional 220/380 VAC -37% +22% 3P+N+PE) At Full Load >0.99 45 - 65 Hz (Selectable) <3% OUTPUT Voltage Range Voltage Tolerance Efficiency Frequency Tolerance THD (THDv) Crest Factor (CF) Overload Capacity* 380/400/415 VAC 3 Phase + N Static ±1, Dynamic ±3 94.5% 50Hz / 60Hz ±0,01% (Battery Mode) Linear Load < 2% / Non Linear Load < 5% 3:1 At 125% Load 10min, at 150% Load 1min BATTERY Quantity (12V DC VRLA) Charge Capacity ENVIRONMENT...
Open the catalog to page 52 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
20 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
28 Pages