PA460Bi-L Digital Real Time Simulation Power Amplifier Front Panel Rear Panel Technical Data Voltage amplifier Current amplifier Voltage output 6×120V (L-N) Output voltage 0-120V 1×240V (L-L) range Max. output power >60VA (120V range output) Output current 0-5Arms >120VA (240V output) (15A peak) Output voltage range 0-120V Input signal (standard) 0-6Vrms (±8.5Vpek) Output power Output current range 0-5Arms Gain (standard) 20V/V 0.0001VA~500VA (1500VA peak) (15A signal peak)(optional) Input (±14.14Vpek) 1-10000 Turn0-10Vrms ratio range Output power Gain (optional) 12V/V Ratio measurement 30000:1 or 0.0001VA~500VA (1500VA peak) Differential input impedance 20kΩ 45000:5 Turn ratio range 1-10000 Voltage accuracy <0.1%(5V-120V) Ratio measurement 30000:1 Voltage typical accuracy accuracy:0.02% <0.05% or Typ. 0.05% Gur. 45000:5 Harmonic distortion ratio Test≤0.1% Points selected Automatic Linearity ≤0.1% test of all accuracy:0.02% Typ. 0.05% Gur. points Frequency range DC-5kHz±1dB Test Points selected Automatic according to Step response < 20μs test of all standard Input and output delay < 20μs points requirement Phase accuracy 0.2° according to Power supply AC 110V/120V/220V/240V, resolution:0.01min 50/60Hz Current measurement range: 0-15 Weight 27kg A (auto ranging) Chassis/ Dimension(W×H×D) 4U 19 inches/ accuracy: 482mm×172mm×580mm ±0 .02%Typ ±0.05% Gur. Voltage measurement range: 0120V (auto ranging) accuracy: ±0 .02%Typ ±0.05% Gur. Polarity Yes Winding Polarity Test Yes (Phase between±45°) EMC(E&I) EN/IEC 61326-1 Safety EN/IEC 61010-1/112/2-030 EN/IEC 60255-25/27 FCC Part 15:Sub B Subject to modification Phase measurement accuracy: standard 1min Typ. 2min Gur. requirement Environmental conditions Phase measurement accuracy: Operating temperature -5℃~50℃ resolution:0.01min 1min Typ. 2min Gur. Storage temperature -25-+70°C Current measurement range: 0-15 Related humidity 20%RH~85%RH A (auto ranging) resolution:0.01min Pressure 86 kPa~106kPa accuracy: Current measurement range: 0-15 EMC (Emission) IEC-61000-3-2/3 ±0 .02%Typ ±0.05% Gur. A (auto ranging) EMC (Immunity) IEC-61000-4-2/3/4/5/6/11 Voltage measurement range: 0accuracy: 120V (auto ranging) Safety IEC/EN ±0.05% 61010-1:2010; ±0 .02%Typ Gur. UL 61010-1:2012; CAN/CSA-C22.2 No. 61010-1-12 accuracy: Voltage measurement range: 0Surrounding conditions No±0 dust, vibration and severe .02%Typ ±0.05% Gur. 120V (auto ranging) electromagnetic interference Yes Polarity accuracy: Winding Polarity Test Yes (Phase ±0 .02%Typ ±0.05% Gur. CO., LTD. PONOVO POWER between±45°) Polarity Yes BDA, Beijing, China. 100176 No.139 Jinghai Third Road, EMC(E&I) 61326-1 Winding Polarity Test Yes (Phase EN/IEC Tel : +86 (10) 59089666 59089999 Safety Fax: +86 (10)EN/IEC 61010-1/1between±45°) www.ponovo.net 12/2-030 EN/IEC 60255-25/27 EMC(E&I) EN/IEC 61326-1 [email protected] [email protected] FCC Part 15:Sub B Safety EN/IEC 61010-1/1- 6×15A RMS (L-N) Output voltage range(2L-N) 0-120V 3×30A RMS 1×90A RMS Output current range(6L-N) 0-5Arms Max. output power 6×135VA at 15A (15A peak) Output 3×270VA at 30A power 1×450VA (1500VA at 90A peak) 0.0001VA~500VA Input Signal (standard) Turn ratio0-5Vrms range (±7.07Vpek) 1-10000 Ratio measurement 30000:1 or Gain (standard) 3A/V Input signal (optional) 45000:5 0-10Vrms (±14.14Vpek) Gain (optional) 1.5A/V accuracy:0.02% Differential input impedance 20kΩ Typ. 0.05% Gur. Test Points selected Automatic Current accuracy 0.2%(0.5-15A) test of all Current typical accuracy <0.1% points Phase accuracy 0.2° according to Harmonic distortion ratio ≤0.2% standard Frequency range DC-5kHz±1dB Step response < 20μs requirement Input/output delay < 20μs Phase meas
Open the catalog to page 115 Pages
7 Pages
10 Pages
2 Pages
22 Pages
21 Pages