1. Catalogs
  2. PONOVO POWER CO., LTD
  3. PA460Bi-C Digital Real Time Simulation Power Amplifier Datasheet_EN_2026 V2

PA460Bi-C Digital Real Time Simulation Power Amplifier Datasheet_EN_2026 V2

PA460Bi-C Digital Real Time Simulation Power Amplifier Datasheet_EN_2026 V2

Product catalog summary
Environmental Conditions
Operating temperature ranges from -5℃ to 50℃, while storage temperature ranges from -25℃ to +70℃. The relative humidity should be between 20%RH and 85%RH, and the pressure should be between 86 kPa and 106 kPa. The device complies with EMC emission standards IEC-61000-3-2/3 and immunity standards IEC-61000-4-2/3/4/5/6/11. Safety standards include IEC/EN 61010-1:2010, UL 61010-1:2012, and CAN/CSA-C22.2 No. 61010-1-12. The surrounding conditions should be free from dust, vibration, and severe electromagnetic interference.
Power Supply and Physical Specifications
The power supply options are AC 110V/120V/220V/240V at 50/60Hz. The device weighs 27kg and has a chassis dimension of 4U 19 inches, measuring 482mm×172mm×580mm.
Current Amplifier Specifications
The maximum current output is 6×15A RMS (L-N), 3×30A RMS (2L-N), and 1×90A RMS (6L-N). The maximum output power is 6×135VA at 15A, 3×270VA at 30A, and 1×450VA at 90A. The standard input signal is 0-5Vrms with a gain of 3A/V, while the optional input signal is 0-10Vrms with a gain of 1.5A/V. The differential input impedance is 20kΩ. Current accuracy is 0.2% for 0.5-15A, with typical accuracy being less than 0.1%. Phase accuracy is 0.2°, harmonic distortion ratio is ≤0.2%, and the frequency range is DC-5kHz±1dB. The step response and input/output delay are both less than 20μs, with linearity ≤0.2%.
Output and Measurement Specifications
The output voltage range is 0-120V, and the output current range is 0-5Arms (15A peak). The output power ranges from 0.0001VA to 500VA (1500VA peak). The turn ratio range is 1-10000, with ratio measurement accuracy of 0.02% typical and 0.05% guaranteed. Automatic test points selection is available according to standard requirements. Phase measurement accuracy is 1min typical and 2min guaranteed, with a resolution of 0.01min. Current measurement range is 0-15A (auto-ranging) with accuracy of ±0.02% typical and ±0.05% guaranteed. Voltage measurement range is 0-120V (auto-ranging) with the same accuracy levels. Polarity and winding polarity tests are supported, with phase between ±45°.
See more

Catalog excerpts

PA460Bi-C Digital Real Time Simulation Power Amplifier  Datasheet_EN_2026 V2-1

PA460Bi-C Digital Real Time Simulation Power Amplifier Front Panel Rear Panel Technical Data Current amplifier Environmental conditions resolution:0.01min Current measurement A (auto ranging) accuracy: ±0 .02%Typ ±0.05% Gur. Voltage measurement range: 0120V (auto ranging) accuracy: ±0 .02%Typ ±0.05% Gur. Polarity Yes Winding Polarity Test Yes (Phase Output voltage range 0-120V Operating temperature -5℃~50℃ Output current range 0-5Arms Storage temperature -25-+70°C (15A peak) Related humidity 20%RH~85%RH Output power Pressure 86 kPa~106kPa 0.0001VA~500VA (1500VA peak) EMC (Emission) IEC-61000-3-2/3 Turn ratio range 1-10000 EMC (Immunity) IEC-61000-4-2/3/4/5/6/11 Ratio measurement 30000:1 or Safety IEC/EN 61010-1:2010; 45000:5 UL 61010-1:2012; CAN/CSA-C22.2 No. 61010-1-12 Surrounding conditionsaccuracy:0.02% No dust, vibration and severe Typ. 0.05% Gur. electromagnetic interference Test Points selected Automatic test of all Power supply AC 110V/120V/220V/240V, points 50/60Hz according to Weight 27kg standard Chassis/ Dimension(W×H×D) 4U 19 inches/ requirement 482mm×172mm×580mm Phase measurement accuracy: 1min Typ. 2min Gur. Subject to modification Output voltage range 0-120V 6×15A RMS (L-N) Output current range 3×30A RMS (2L-N) 0-5Arms (15A peak) 1×90A RMS (6L-N) Output power Max. output power at 15A Output voltage range 0.0001VA~500VA 0-120V6×135VA (1500VA peak) 3×270VA at 30A Output current range Turn ratio 0-5Arms range 1×450VA at 90A1-10000 (15A peak) Ratio measurement 30000:1 or Input Signal (standard) 0-5Vrms (±7.07Vpek) Output 45000:5 power Gain (standard) (1500VA peak) 3A/V 0.0001VA~500VA Input (optional) 0-10Vrms (±14.14Vpek) Turn Signal ratio range 1-10000 accuracy:0.02% Typ. 0.05% Gur. Gain (optional) 1.5A/V Ratio measurement Test Points 30000:1 or selected Automatic Differential 20kΩ 45000:5 input impedance test of all Current accuracy 0.2%(0.5-15A)points Current typical accuracy accuracy:0.02% Typ. 0.05% Gur. <0.1% according to Phase accuracy 0.2° Test Points selected Automatic standard Harmonic distortion ratio test of≤0.2% all requirement Frequency range points DC-5kHz±1dB Phase measurement accuracy: according toGur. Step response < 20μs 1min Typ. 2min standard< 20μs Input/output delay requirement Linearity ≤0.2% resolution:0.01min Phase measurement Currentaccuracy: measurement range: 0-15 1min Typ. 2min Gur. A (auto ranging) PONOVO POWER CO., LTD. accuracy: No.139 Jinghai Third Road, BDA, Beijing,Gur. China. 100176 resolution:0.01min ±0 .02%Typ ±0.05% Telmeasurement : +86 {10) 59089666 Fax: +86 (10) 59089999 Current range: 0-15 Voltage measurement range: 0A (autowww.ponovo.net ranging) 120V (auto ranging) [email protected] [email protected] accuracy: accuracy: ±0 .02%Typ ±0.05%±0 Gur. .02%Typ ±0.05% Gur. Voltage measurementPolarityrange: 0Yes 120V (auto ranging) Winding Polarity Test Yes (Phase PONOVO PO

 Open the catalog to page 1

All PONOVO POWER CO., LTD catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry