Overview: The L336EXi-E Digital Protection Relay Test Set is a comprehensive device designed for testing and calibrating protection relays. It offers a wide range of output capabilities, precise measurements, and robust safety features.
Specifications:
  • Output Voltage and Current: Voltage range of 0-120V and current range of 0-5Arms (15A peak), with power output from 0.0001VA to 500VA (1500VA peak).
  • Measurement Accuracy: Voltage and current measurement accuracy is ±0.02% typical and ±0.05% guaranteed.
  • Phase and Ratio Measurement: Phase measurement accuracy is 1min typical and 2min guaranteed, with a resolution of 0.01min. Turn ratio range is 1-10000 with a measurement ratio of 30000:1 or 45000:5.
  • Safety and Standards: Complies with EN/IEC 61326-1, EN/IEC 61010-1/1-12/2-030, EN/IEC 60255-25/27, and FCC Part 15: Sub B.
AC and DC Outputs:
  • AC Current Outputs: Independent control with a range of 4×20A/1×80A, accuracy error < 0.08% rd. + 0.02% rg. guaranteed, and harmonic distortion ≤0.2%.
  • DC Current Outputs: Range of 4×10A with accuracy of ±5mA (0.2A~1A) and ±0.5% (1A~10A).
  • AC Voltage Outputs: 4-phase AC (L-N) with a range of 4×0~300V and 1-phase AC (L-L) with a range of 1×0~600V.
General Features:
  • Frequency Range: 10Hz~1kHz with accuracy <0.5mHz and resolution of 0.001Hz.
  • Auxiliary DC Supply: Voltage range of 48V~264V with power of 88W at 110V and 110W at 220V.
  • Binary Inputs and Outputs: 8 binary inputs with potential-free contacts or DC voltage, and 4 binary outputs with potential-free relay contacts.
Connectivity and Control:
  • PC Connection: 2 Ethernet ports and WIFI (802.11 b/g/n) for remote control.
  • Local Display: 10.4-inch TFT LCD touch screen for local control.
Environmental and Safety:
  • Operating Conditions: Temperature range of 0~50ºC, storage temperature of -25~+70ºC, and relative humidity of 5~95% non-condensing.
  • Protection: All outputs are overload and short circuit proof, with protection against high-voltage transients and over temperature.
See more

Catalog excerpts

L336EXi-E SUPER-LIGHT Digital Protection Relay Test Set Datasheet_EN_2026 V6.pdf-1

L336EXi-E Digital Protection Relay Test Set Specifications AC Current outputs Control Independent control of amplitude, frequency and phase angle Output voltage range 0-120V Range 4×20A/1×80A Output current range 0-5Arms error < 0.08% rd. + 0.02% rg. guar. Accuracy (15A peak) error < 0.03% rd. + 0.02% rg. typ. Output power Resolution 0.0001VA~500VA (1500VA peak)1mA(≤10A), 5mA(10~40A) 4×225VA (20A/phase) Turn ratio range 1-10000 Max output power 1×450VA (50A) Ratio measurement 30000:1 or Current 45000:5rise/drop time <100µs Harmonic distortion (THD%) accuracy:0.02% Typ. 0.05% Gur. Frequency 10Hz~1kHz Test Points selected Automatic test of all continuous (<5A/channel) >30s (5~10A/channel) points Output time >15sto(10~15A/channel) according >10s (15~20A/channel) standard Operation indication Automatic detection and alarm when overload, distortion and open circuit requirement Phase measurement accuracy: DC Current outputs 1min Typ. 2min Gur. resolution:0.01min Accuracy Current measurement A (auto ranging) Resolution accuracy: Max output power 100W (10A) ±0 .02%Typ ±0.05% Gur. Operation indication Overload Voltage measurement range: 0- protection automatically 120V (auto ranging) AC Voltage outputs accuracy: Control Independent control of amplitude, frequency and phase angle ±0 .02%Typ ±0.05% Gur. Polarity ac(L-N) Yes 4×0~300V 4-phase Winding Polarity Test Yes (Phase 1-phase ac(L-L) 1×0~600V between±45°) Fourth voltage (Uz)EN/IEC 61326-1Can be set as zero sequence voltage, line extraction voltage, or any value EMC(E&I) Safety EN/IEC 61010-1/1error < 0.03% rd. + 0.02% rg. guar. Accuracy 12/2-030 EN/IEC 60255-25/27 error < 0.015% rd. + 0.005% rg. typ. FCC Part 15:Sub1mV(<30V), B Resolution 10mV(30V~300V) Others ECS-001:2006LVD EU

 Open the catalog to page 1
L336EXi-E SUPER-LIGHT Digital Protection Relay Test Set Datasheet_EN_2026 V6.pdf-2

Note: @ test at 50Hz/60Hz condition.

 Open the catalog to page 2
L336EXi-E SUPER-LIGHT Digital Protection Relay Test Set Datasheet_EN_2026 V6.pdf-5

Developed and manufactured under an ISO9001:2015 registered system Specifications are subject to modification without notice PONOVO POWER CO., LTD. No.139 Jinghai Third Road, BDA, Beijing, China. 100176

 Open the catalog to page 5

All PONOVO POWER CO., LTD catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.