Group: PONAR
Catalog excerpts
PRESSURE SEQUENCE VALVE TYPE DZ5DP NG 5 Pressure sequence valves are used for connecting a second hydraulic system when pressure in a main system reaches the set value. The valve can be mounted in systems in any positions. The sequence valve comprises the housing 1, control spool 2, pressure spring 3, pressure setting element 4 and optional check valve 5. Sequence pressure is adjusted by means of the pressure setting element 4. The spring 3 holds the control spool 2 in neutral position and the valve is closed. Pressure in line P affects the spool surface opposite the spring 3 via the control line 6 and jet 6. When the pressure in line P reaches the value set, the con- trol spool moves and opens the connection A to B. The hydraulic system connected at port A is actuated, without any decrease in pressure at port P. Supply of control fluid may also be external, via port X. Depending on the valve application, the pilot fluid drain is either external via port T (Y) or internal. A check valve 5 may be mounted for free flow through the valve from B to A.
Open the catalog to page 1TECHNICAL DATA Hydraulic fluid Mineral oil or phosphate ester Nominal fluid viscosity Viscosity range Optimum working temperature( fluid in a tank ) Fluid temperature range Required fluid filtration Recommended fluid filtration Max allowable flow rate OVERALL DIMENSIONS 1 - Adjustment by handknob =1 2 - Adjustment by set screw with internal hexagon =2 3 - Adjustment by lockable handknob =3 4 - Sealing ring - o-ring 7 × 1.5 at ports P, A, T (Y), B (X) - Admissible surface roughness and flatness deviation for a subplate face. WK 450 447
Open the catalog to page 2PERFORMANCE CURVES, Basic version Internal pilot supply Internal pilot drain Version X External pilot supply Internal pilot drain Version Y Internal pilot supply External pilot drain Version XY External pilot supply External pilot drain Without check valve With check valve
Open the catalog to page 3HOW TO ORDER Orders coded in the way showed below should be forwarded to the manufacturer. Adjustment method Hand knob Set screw with internal hexagon Lockable hand knob Further requirements in clear text ( to be agreed upon with the manufacturer ) Series number Fluids on mineral oil base = with no code Fluids on phosphate-ester base 20 = 20 ( 20 - 29 ) - installation and connection dimensions remain unchanged Check valve With check valve Without check valve Pilot supply and drain Pilot Pilot Pilot Pilot CONNECTION DIMENSIONS FOR SUBPLATES Subplate G 115/01 ( G1/4 ) Weight - 0.7 kg suply...
Open the catalog to page 41 - valve mounting surface 2 - recess in subplate face Fixing bolts : M5 × 50 - 8.8 PN - 87/M - 82302 ( DIN 912 ) - 4 pcs , torque = 9 Nm Note : Subplate and fixing bolts must be ordered separately
Open the catalog to page 5e-mail: ponar@ponar-wadowice.pl
Open the catalog to page 6All PONAR S.A. catalogs and technical brochures
-
PRESSURE SWITCH TYPE USPH 1
4 Pages
-
MK series
4 Pages
-
MG series
4 Pages
-
ZRR6
8 Pages
-
UZKB 6
6 Pages
-
DR5DP
6 Pages
-
UZPD30
8 Pages
-
Reverse valve type URJP10
4 Pages
-
Directional spool valve type WE6
16 Pages
-
General Catalogue
1200 Pages
-
Catalogue products
20 Pages
Archived catalogs
-
Blocks
4 Pages
-
Hydraulic Systems
41 Pages
-
Hydraulic Cylinders
11 Pages