Product catalog summary
Introduction & Benefits
Pomanique’s ZX-Series is a three-phase, electronically controlled, vacuum-interrupting distribution automation switch designed for reliable and economical switching, sectionalizing, advanced metering, and automation systems for distribution circuits up to 38 kV. It features solid cycloaliphatic-epoxy vacuum interrupters and a magnetic actuator for a lifetime of trouble-free operation. The switch is resistant to ozone, oxygen, moisture, contamination, and UV light. It meets IEEE C37.60 and IEC 62271-111 standards for outdoor use.

Controlled Arc Fault Venting
The recloser uses vacuum interrupters to quench arc faults quickly. It recognizes less-than-critical instantaneous overcurrent, ensuring arc fault containment and venting. The speed of open operation is controlled to at least 1.2m/s for effective venting.

High Reliability
The ZX recloser features a simple, magnetically actuated operating mechanism with only one moving part, ensuring maximum reliability and minimal maintenance.

Switch Unit Description
Reclosers are used in overhead lines and substations, capable of switching normal and fault currents. They can trip and reclose up to four times in case of temporary line faults, reducing network interruptions.

Design of Switch Unit
Each vacuum interrupter is embedded in a solid-insulated pole made of weather-proof cycloaliphatic epoxy-resin, providing a long service life. The operating mechanism is a bi-stable system with permanent magnets, housed in stainless steel for outdoor applications.

Controller Description
The FTU-R200 controller provides protection, control, instrumentation, and metering with integrated logic, data logging, and fault reports. It supports multiple communication protocols and is mounted in a control cubicle with auxiliary power supply and batteries.

Enhanced Features
Includes power quality monitoring, fault waveform recording, harmonics analysis, and automatic isolation of faulted sections. It supports multi-protocol communication and user-programmable logic.

General Protection Features
Features include selectable reclose times, high current trip settings, sensitive earth fault detection, cold load pickup, under/over voltage protection, synchronism check, and frequency protection.

Technical Data
The document provides detailed technical specifications for various models of the ZX recloser, including nominal operating voltage, breaking capacity, continuous rated current capacity, and more.

Contact Information
Pomanique Electric Co., Ltd., located in Yueqing, Zhejiang, China. Contact details include phone, fax, email, and website.
See more

Catalog excerpts

Pomanique Vacuum Recloser ZX38 series-2

Introduction & Benefits Pomanique’s ZX-Series three-phase, electronically controlled, vacuuminterrupting distribution automation switch provides reliable, economical switching, sectionalizing, advanced metering, and automation systems for distribution circuits rated up to 38 kV. Controlled Arc Fault Venting ability - Adoptvacuuminterrupters,thereclosercanquenchtheAcrfault Withinveryshorttime. TheAFVrecognizesless-than-criticalinstantaneousovercurrent,so duringthedesignofRecloser,thearcfaultcontainmentandventing hasbeenamandtoryrequirement. The ZX switch combines solid cycloaliphatic- epoxy vacuum...

 Open the catalog to page 2
Pomanique Vacuum Recloser ZX38 series-3

Switch unit description Recloser principle Reclosersareusedinoverheadlinesandinsubstations.Likecircuit-breakers theyarecapableofswitchingnormalandfaultcurrents.Theyareequipped withsensorsandcontrollerbeingtheprotectionandcontroldevice.Incase of a temporary line fault, they can trip and reclose up to four times, thus avoidinglongernetworkinterruptions. Recloser cycle Incaseofanetworkfault,therecloseropensandreclosesseveraltimes.In case of temporary faults, the automatic reclosing significantly reduces the outage times. While the trip settings for each operation can be set individually. Design...

 Open the catalog to page 3
Pomanique Vacuum Recloser ZX38 series-4

Controller description TheMicroprocessorBasedcontroller FTU-R200provideprotection,control, instrumentation and metering with integrated input and output logic, data logging&faultreports. Communication access to controller functionality is via electrical RS485 port for remote connection. Additional rear port options including RS232 port is available. Thecontrollerismountedinthecontrolcubicle.Alongwiththecontroller,this cubicle also contains the auxiliary power supply with batteries for uninterruptiblepowersupply,electronicboardsandcircuitbreakers. The controller contains a large number of protection...

 Open the catalog to page 4
Pomanique Vacuum Recloser ZX38 series-5

General Protection Features Operating sequence Sensitive Earth Fault (SEF) PickupI0:0.1~20A(step:0.1A) Reclose times are selectable. The operating sequence is V0:10~80%(step:1%) definedby: OperatingAngle:0~345°(1°step) O-1strt-CO-2ndrt-CO-3rdrt–CO OpeartingTime:0.1~30sec(step:0.1sec) _Reclos Under/ Over Voltage Protection VoltageUnerLevel:50~90% Negative Sequence Overcurrent(Broken conductor) PickupI2/I1level:30.0~100.0(step:1%) I2/I1delaytime:0.01~100.0(step:0.01sec) High Current Trip (HCT) Phase-HCTPickupLeve:10~2000A(step:0.1A) Phase-HCTAdder:0.01~1(step:0.01sec) Ground-HCTPickupLeve:10~2000A(step:1A)...

 Open the catalog to page 5
Pomanique Vacuum Recloser ZX38 series-6

General Protection Features Commmunication Interface Recording Events On FRTU left-side (inside the inner door) Fault Waveform Load Profiling Baud Rate Local / Remote : Control Position (only locally changeable) Open/Close : Switch Body Status Change Command DO (Direct Operate) and SBO (Select Before Operate) On FRTU Front Panel Reset : Annunciator Manual Reset Command Battery Test : Battery & Charger Circuit Check Protection Function Blocking User Configurable DO Points (reserved) : 2 ProtocolMonitor(CommunicationFrameCheck) Real-timeDisplay:MeasurementandStatusData EventListandFaultOscillograph...

 Open the catalog to page 6
Pomanique Vacuum Recloser ZX38 series-7

Technical characteristics Pomanique Value Manufacturing standard Nominal operating voltage Voltage Range Breaking Capacity Continuous rated current capacity Cable charging current Line charging current Short-term nominal allowable current capacity. Lightning impulse withstand voltage. Power frequency withstand voltage (1 min dry) Secuencia de Operación Nominal Minimum amount of operation Number of Voltage Sensors Current Transformer Number / Ratio Mechanism Type Magnetic Actuator Minimum external creepage distance Enclosure Material Relay protection functions Protection Current Range Communication...

 Open the catalog to page 7
Pomanique Vacuum Recloser ZX38 series-8

Rated short-duration P.F. withstand voltage Max. interrupting time / max. closing time Cable charging current Line charging current Rated lightning impulse withstand voltage Minimum clearance, phase-toearth Rated short-circuit making current Clearance, phase-to-phase Rated short-circuit breaking current Creepage distance, phase-toearth Rated duration of short-circuit Impedance μΩ between connections Rated continuous current Technical data

 Open the catalog to page 8
Pomanique Vacuum Recloser ZX38 series-9