1. Catalogs
  2. PolyScience
  3. Low Temperature Coolers

Low Temperature Coolers

Low Temperature Coolers

Low Temperature Coolers

Product catalog summary
Overview: The document provides detailed information on PolyScience Low Temperature Coolers, designed to enhance low-temperature laboratory work. These coolers are available in immersion probe and flow-through styles, offering rapid and cost-effective cooling of liquids to temperatures as low as -100°C. They are suitable for applications such as cooling exothermic reactions, freeze point determinations, freeze drying, impact testing, lyophilization, and vapor and solvent trapping.
Types of Coolers:
  • Immersion Probe Style Coolers: Ideal for trapping and Dewar-type applications, reducing the need for dry ice or liquid nitrogen. They feature a flexible hose for convenient placement.
  • Flow-through Style Coolers: Extend the temperature range of non-refrigerated circulators and enhance the cooling capacity of refrigerated circulators. They provide an economical alternative to tap water cooling for heated circulating baths.
Features:
  • Continuous cooling to temperatures as low as -100°C.
  • Designed for maximum cooling efficiency.
  • Economical alternative to dry ice or liquid nitrogen.
  • Suitable for trapping applications, freeze drying, and rapid cooling of small liquid volumes.
Immersion Probe Coolers Specifications:
  • IP-100: Temperature range of -100° to -60°C, cooling capacity of 85 W at -65°C, and available with rigid coil, cold finger, or flexible probes.
  • IP-80: Temperature range of -80° to -40°C, cooling capacity of 150 W at -60°C, with a rigid coil probe.
  • IP-60: Temperature range of -60° to -20°C, cooling capacity of 75 W at -20°C, with a rigid coil probe.
  • IP-35: Temperature range of -35° to +40°C, cooling capacity of 1004 W at 20°C, with a rigid coil probe.
Flow Through Cooler Specifications:
  • FT Series: Temperature range of -25° to +40°C, cooling capacity of 745 W at 20°C, and requires an external circulator for temperature control.
Additional Information: The document includes part numbers for different models and specifies that electrical plugs are standard U.S. and European types, with additional options available.
See more

Catalog excerpts

Low Temperature Coolers-1

Low Temperature Coolers Two simple ways to chill. Enhance and simplify your low-temperature laboratory work with a PolyScience Low Temperature Cooler. Available in both immersion probe and flow-through styles, they provide rapid, low-cost cooling of liquids to temperatures as low as -100°C. Typical applications include the cooling of exothermic reactions, freeze point determinations, freeze drying, impact testing, lyophilization, and vapor and solvent trapping. • Immersion Probe Style Coolers Excellent for trapping and Dewar-type applications and reduce the expense of using dry ice or liquid nitrogen. A flexible hose allows convenient placement of the cooling probe. • Flow-through Style Coolers Extend the temperature range of non-refrigerated circulators to below ambient and boost the cooling capacity of refrigerated circulators. These coolers also offer an extremely economic alternative to the tap water cooling of heated circulating baths when rapid cool-downs or operation at or near ambient is needed.

 Open the catalog to page 1
Low Temperature Coolers-2

Chillers and Coolers | Coolers | Low Temperature Low Temperature Coolers — Immersion Probe Key Specifications Temperature Range: Cooling Capacity: Temperature Fixed at -100°C Fixed at -80°C Fixed at -60°C Fixed at -35°C Control: Temperature Readout: Features: • ontinuous cooling to temperatures as low as -100°C C • esigned to run at maximum cooling D • n economical alternative to dry ice or liquid nitrogen A • xcellent for trapping applications, freeze drying, and E rapidly cooling small volumes of liquids Rigid Cold Finger Rigid Coil Flexible Cold Finger Immersion Probe Dimensions Insulated...

 Open the catalog to page 2
Low Temperature Coolers-3

Probe: Rigid Coil (3"/7.62 cm), Cold Finger, or Flexible Probe: Rigid Coil (1.5"/3.81 cm) Probe: Rigid Coil (1.5"/3.81 cm) Probe: Rigid Coil (1.75"/4.44 cm or 3"/7.62 cm) Overall Dimensions: (L x W x H) 20.1 x 15 x 22.3" 51.1 x 38.1 x 56.6 cm Rigid Coil Part Number: 120 VAC/60 Hz: P10N6A101B 240 VAC/60 Hz: P10N6A102E Rigid Cold Finger Part Number: 120 VAC/60 Hz: P10N3A101B 240V/60Hz: P10N3A102E Overall Dimensions: (L x W x H) 17 x 14 x 14" 43.2 x 35.6 x 35.6 cm 1.75" Rigid Coil Part Number: 120 VAC/60 Hz: P40N7A101B 240 VAC/50 Hz: P40N7A102E 3" Rigid Coil Part Number: 120 VAC/60 Hz: P35N5A101B...

 Open the catalog to page 3

All PolyScience catalogs and technical brochures

  1. Full Catalog

    156  Pages

  2. PolyScience

    156  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.