This document is a comprehensive catalogue from POLYLUX, detailing their extensive range of transformers, autotransformers, and reactors for various applications. It highlights the company's 50+ years of experience in the industry, their global reach, and commitment to quality and innovation.
Product Categories- Harmonic Compensators: Designed for both office and industrial installations, these devices help manage electrical harmonics in networks.
- Single-phase Control and Isolation Transformers: Available with various input and output voltage configurations, these transformers are used for isolation and voltage conversion.
- Ultra-isolation Transformers: Provide enhanced isolation with options for additional screens.
- Transformers for Spotlights: Specifically designed for pool and garden lighting, compatible with LED and halogen lamps.
- IP54-rated Encapsulated Transformers: Offer protection against dust and water, suitable for various environments.
- Voltage Measuring Equipment Transformers: Used for precise voltage measurement in electrical systems.
- Switched-mode Power Supply Units: Provide DC output from AC input, available in single-phase and three-phase configurations.
- Transformers for Medical Installations: Ensure safety and reliability in medical environments.
- Voltage Regulators for Solar Inverters: Maintain stable voltage output for solar energy systems.
- Harmonic Filtering Reactors: Used in both single-phase and three-phase networks to filter electrical harmonics.
- Isolation Transformers: Provide electrical isolation and voltage conversion, available in ecological and standard models.
- Special Transformers: Include reversible autotransformers and those for solar inverters.
Manufacturing and Quality Assurance
POLYLUX emphasizes continuous improvement and quality assurance through processes like dip varnishing, flame retardant resin encapsulation, and the use of high-efficiency magnetic cores. All products undergo automatic checks and tests to ensure compliance with international standards.
Certifications
The company holds several certifications, including ISO 9001, UL, CE, and Carbon Footprint, reflecting their commitment to quality, safety, and sustainability.
Online Resources and Tools
POLYLUX offers a range of online tools, including product finders, calculators, tutorials, and a virtual assistant to support customers in selecting and using their products effectively.
Customer Focus
With a strong emphasis on customer service, POLYLUX provides technical support and custom solutions to meet the specific needs of different sectors, including energy, industrial, marine, railway, renewable energies, medical, lighting, data centers, and oil & mining.
PTU and QTU Series OverviewThe document provides detailed specifications and features of the PTU and QTU series of
single-phase transformers, designed for ultra-isolation with input and output voltages of 230 V. It also covers the PIL series for LED spotlights in pools and gardens with an output voltage of 12 V.
PTU Series:- Specifications: Available in models PTU1P and PTU3P, with power ratings from 40 VA to 4000 VA. Input and output protections are specified with MCB and fuse ratings.
- Design Features: Includes electrostatic shields, LED indicator lamps, and a robust design for increased insulation and easier connections.
- Applications: Suitable for environments requiring ultra-isolation and noise reduction.
QTU Series:- Specifications: Encapsulated transformers with power ratings from 40 VA to 2500 VA. Designed for high electrical noise environments.
- Design Features: Includes 1 or 3 electrostatic shields, resin encapsulation for vibration resistance, and protective terminal covers.
- Applications: Ideal for damp, saline, and corrosive environments, offering noise and parasite attenuation.
PIL Series:- Specifications: Designed for LED spotlights with power ratings from 30 VA to 100 VA. Provides an output voltage of 12 V.
- Design Features: Includes anti-flash dip varnishing, IP20 enclosure, and LED indicator lamps.
- Applications: Suitable for pool and garden lighting, offering safety and ease of installation.
General Features:- All transformers comply with IEC/EN/UNE-EN 61558 standards and include a CE declaration of conformity.
- They are designed for continuous operation with a frequency range of 50-60 Hz.
- Protection ratings and mounting options vary across models, with some convertible from Class I to Class II.
Single-phase Transformers for LED SpotlightsThe document provides detailed specifications and features of single-phase transformers designed for LED spotlights in pools and gardens. These transformers are manufactured by POLYLUX and are available in different series: PIL, QIL, PIP, and PIQ. Each series is tailored for specific applications and distances between the spotlight and
transformer.
Specifications:- Input Voltage: 230 V
- Output Voltage: 12 V
- Protection Rating: IP20
- Frequency: 50-60 Hz
- Safety Class: Convertible from Class I to Class II
- Standards: IEC/EN/UNE-EN 61558, CE
Common Features:- Encapsulated in flame retardant resin for enhanced safety and durability.
- Equipped with a copper shield between primary and secondary to prevent electrical risks.
- Designed to withstand damp, saline, and corrosive environments.
- Includes LED indicator lamp for operational status.
- Mounting options include DIN rail and screw mounting.
Series Details:- PIL Series: Suitable for LED spotlights with input 230 V and output 12 V. Features include encapsulated live parts and greater resistance to current surges.
- QIL Series: Offers increased wiring insulation and a more compact design. Available in ratings from 30 VA to 100 VA.
- PIP Series: Designed for varying distances between spotlight and transformer, with output adjustments based on distance. Available in ratings from 100 VA to 600 VA.
- PIQ Series: Similar to PIP but with additional features like anti-flash dip varnishing for noise elimination and compactation.
Technical Features:- Insulators Class: H - 180 ºC
- Temperature Rise Class: B
- Winding Class: HC - 200 ºC
- Noise Level: ≤ 40 dB
- Cooling: AN (Air Natural)
Electrical Connections: The document provides detailed electrical connection configurations for each series, specifying input and output connections based on the distance between the spotlight and transformer.
Conclusion: POLYLUX transformers are designed for safety and efficiency in pool and garden lighting applications, offering various models to suit different installation requirements and distances.
Single-phase Transformers for Safety and Isolation
The document provides detailed specifications and applications for various series of single-phase transformers designed for safety and isolation in electrical installations, particularly for use in pools and gardens. These transformers are designed to mitigate electrical risks and ensure safe operation in environments where electrical contact poses a risk to individuals.
PIN Series: This series is primarily used for spotlights in pools and gardens, with an input of 230 V and an output of 12 V. Key features include a copper shield between primary and secondary circuits to prevent voltage crossover, copper connection terminals to prevent poor connections, and the ability to mount on a DIN rail up to 300 VA. The transformers are tested individually to ensure compliance with standards IEC/EN/UNE-EN 61558 and CE.
PIPZ Series: Similar to the PIN series, the PIPZ series is used for spotlights in pools and gardens but offers additional protection with IP54/IP56 enclosures. These transformers are encapsulated in flame-retardant resin for enhanced isolation and noise reduction. They also feature copper shields and are tested for compliance with relevant standards.
IP Series: These transformers are designed for galvanic isolation in single-phase installations, featuring an IP66 rated metal enclosure for outdoor use. They are encapsulated in flame-retardant resin, providing high resistance to vibrations and damp conditions. The series supports a range of power ratings from 200 VA to 1600 VA and is compliant with IEC/EN/UNE-EN 61558 standards.
TP Series: The TP series consists of portable transformers for continuous service, providing low voltage outputs of 12 V or 24 V. They are ideal for use in difficult-to-reach areas or where there is no power socket, offering high resistance to environmental factors such as vibrations, dampness, and corrosion.
Technical Specifications: Across the series, the transformers feature various power ratings, input and output configurations, and protection ratings. They are designed to operate continuously with a frequency of 50-60 Hz and a noise level of ≤ 45 dB. The document includes detailed electrical diagrams, connection instructions, and protection guidelines for each series.
Technical Specifications and Features of Various Transformer Series
The document provides detailed technical specifications and features of various transformer series, including TP, PTM, QTM, and TM series, designed for different applications such as safety and measuring equipment. Each series is encapsulated in flame retardant resin and includes features like safety class compliance, noise reduction, and protection ratings.
TP Series: This series includes single-phase transformers with input voltage of 230 V and various output voltages (12 V, 24 V, 110 V, 230 V). Key features include flame retardant resin encapsulation, safety Class II, short circuit protection, and compliance with IEC/EN/UNE-EN 61558 standards. The transformers are designed for continuous operation with a protection rating of IP66.
PTM Series: Designed for measuring equipment, these transformers offer precise output voltage isolation. They feature anti-flash dip varnishing, IP20 enclosure, and are suitable for mounting on DIN rails. The series supports continuous surge currents and complies with IEC/EN/UNE-EN 61869-3 standards.
QTM Series: Similar to the PTM series, the QTM series is encapsulated for measuring equipment with enhanced mechanical resistance and protection against environmental factors. It includes a LED indicator lamp and supports precision classes based on power.
TM Series: This series is also for measuring equipment, offering precise voltage isolation and built with independent circuits for three-phase systems. It features IP20 protection, resistance to surge currents, and compliance with relevant standards.
Technical Features: Across the series, common technical features include insulators Class H (180ºC), temperature rise Class B, winding Class HC (200ºC), and operation at frequencies of 50-60 Hz. The transformers are designed to operate in room temperatures up to 45ºC with noise levels ≤ 45 dB.
Manufacturing and Compliance: All transformers undergo automatic compliance testing to ensure they meet the corresponding standards. They are designed to withstand environmental challenges such as damp, saline, and corrosive conditions.
Technical Specifications and Features of Various Transformer Series and Temperature Control Units
The document provides technical specifications and details for various transformer series and temperature control units, focusing on their applications, standards, and technical features.
1. TMT Series Transformers:- Purpose: Designed for adapting voltage in measuring equipment.
- Standards: Complies with IEC/EN/UNE-EN 61869-3, CE.
- Specifications: Test voltage of 3 kV, inrush current ≤ 5 In, continuous operation, and cooling types AN (TMTX - TMTE) and ANAN (TMTW).
- Terminals: Various terminal types with specific power and torque requirements.
- Measurements: Detailed dimensions and weights for TMTX, TMTW, and TMTE models.
- Options: Custom manufacturing options available for power, frequency, and operation type.
2. Current Transformers (TIB, TIP, TIN Series):- Purpose: Used for energy monitoring, either as measuring or protection transformers.
- Specifications: Standard power ranges, input/output currents, and frequency. Includes thermal and dynamic short circuit current ratings.
- Features: Sealable terminal covers, fastening systems, and compliance with EN 61869-2 standards.
- Models: TIB series for primary winding, TIP series for primary pass-through, and TIN series for open core (split) designs.
3. CTM4 Temperature Control Unit:- Purpose: Measures and controls temperature values for transformers, aiding in preventive diagnostics.
- Features: Includes alarm levels, RS485 serial port for remote control, and programmable outputs.
- Specifications: Operates with PT100 sensors, supports Modbus-RTU protocol, and has an IP65 front cover.
4. MR12 Remote Monitoring System:- Purpose: Provides data gathering and supervisory interface for up to 12 VA40-485 units.
- Features: LCD graphic display, integrated buzzer, and dual RS485 communication interfaces.
- Specifications: Supports Modbus RTU protocol and optional Ethernet interface.
Conclusion: The document outlines the technical capabilities and applications of various transformer and monitoring systems, emphasizing compliance with international standards and offering customization options for specific operational needs.
Technical Specifications and Features of Various Electrical Components and Systems
The document provides detailed technical specifications and features of various electrical components and systems, primarily focusing on insulation monitors, transformers, and power supply units used in medical and industrial applications.
1. Insulation Monitors:- The VA40 series insulation monitor detects leakage currents by applying a direct current measuring signal between the insulated line and ground. It includes a digital filter and encoded signal for efficiency.
- Features include temperature control for medical isolation transformers, remote failure condition monitoring via CR5 panels, and integration with PLC/PC systems using Modbus RTU protocol.
- Specifications: Supply voltage of 110-230 V, operating temperature of -10 to 60 ºC, and protection rating of IP20.
2. CR5 Remote Signalling Panels:- These panels report insulation monitor alarms in manned rooms, providing acoustic and luminous signals for low insulation or overload alarms.
- Features include a test button, acoustic silence button, and easy installation in a universal E503 box.
- Specifications: Operating temperature of -10 to 60 ºC, protection rating of IP30, and compliance with IEC standards.
3. Current Transformers (TI1 Series):- Designed for constant reading of transformer’s secondary current, activating alarms in case of overload.
- Specifications include a reference voltage for isolation of 0.72 kV, operating frequency of 50-60 Hz, and protection rating of IP20.
4. Power Supply Units (FCP and FCPT Series):- FCP series offers single-phase power sources with high power density, universal input range, and protection against surge currents.
- FCPT series provides three-phase power sources for continuous power supply in automatic control systems and other applications.
- Specifications: Standard output voltage of 12 V (FCPB) and 24 V (FCP), IP20 protection rating, and compliance with EN and UL standards.
5. Isolation Transformers (TH Series):- Designed for clinical electrical installations, ensuring patient safety with features like anti-flash varnish finish and electrostatic shield.
- Specifications: Input and output voltage of 230 V, noise level ≤ 35 dB, and compliance with IEC and UL standards.
Conclusion: The document outlines the technical features and applications of various electrical components, emphasizing safety, efficiency, and compliance with international standards. These components are crucial for maintaining reliable and safe electrical systems in medical and industrial environments.
Technical Specifications and Features of Various Transformer Series for Clinical Electrical InstallationsThe document provides detailed specifications and features of various transformer series designed for clinical electrical installations, focusing on safety and efficiency. It includes single-phase and
three-phase transformers, each tailored for specific medical applications.
TH Series: These are isolation transformers for clinical electrical installations with an input and output of 230 V. They are designed to meet the EN 61558-2-15 standard, ensuring safety in medical environments. The series includes models with power ratings from 1 kVA to 10 kVA, featuring IP00, IP20, and IP23 protection ratings.
TLQ Series: This series is specifically designed for operating theatre spotlights, offering input voltages of 230±5% V and output voltages ranging from 0-24 V to 27 V. Key features include a copper shield between primary and secondary windings, anti-flash dip varnishing, and the option for DIN rail mounting. The transformers comply with IEC/EN/UNE-EN 61558-1 standards.
TTH Series: These transformers are used for insulation in clinical installations, with input voltages of 400 V and output of 230 V. They are encapsulated in resin for protection against moisture and corrosion, and are available in power ratings from 0.40 kVA to 400 kVA. The series includes models with IP00, IP20, and IP23 protection ratings.
TTFK Series: Designed for three-phase networks with high harmonic levels, these transformers can handle overheating from non-linear load harmonics. They are available with k factors of 13 and 20, indicating their capacity to manage harmonic loads. The series offers power ratings from 10 kVA to 500 kVA and includes models with IP00, IP23, and IP65 protection ratings.
Technical Features: Across the series, the transformers are designed with high insulation classes, temperature rise classes, and are tested for compliance with relevant standards. They feature robust construction with anti-flash varnishing, electrostatic shields, and various mounting options to ensure safety and reliability in medical environments.
Technical Specifications and Features of Various Harmonic Compensators
The document provides detailed specifications and options for various series of harmonic compensators designed for office and industrial installations. It includes technical data, manufacturing options, and performance characteristics for different models.
Specifications: The document lists multiple series such as C10D, C20D, C22D, C25D, and C30D, each with specific power ratings (kVA), dimensions, weight, and fastening elements. The compensators are designed to handle different phase and neutral currents, with varying insulation classes and protection ratings.
Manufacturing Options: Options include power ratings from 10 kVA to 250 kVA, copper or aluminum windings, frequency ranges from 50 Hz to 400 Hz, and various IP and IK ratings. Additional features include temperature sensors, electrostatic shields, and anti-condensation systems.
Performance and Standards: The compensators are designed to reduce harmonics, phase currents, and voltage distortion. They comply with standards such as IEC/EN/UNE-EN 60076 and 61000-3-2/4, and are CE certified. The document also mentions specific applications for office installations, highlighting the reduction of neutral current and voltage distortion.
Technical Features: The compensators are equipped with features like natural or forced ventilation cooling, anti-vibration systems, and various adjustment options. They are suitable for operation in temperatures up to 60°C and altitudes up to 4000 meters.
Applications: The document outlines solutions for office installations, emphasizing the reduction of homopolar harmonics and improvement of power factor. It also details the use of compensators in industrial settings to address non-homopolar harmonics.
Technical Specifications and Applications for Various Series of Inductances
The document provides detailed information on various harmonic compensators and inductances designed for filtering harmonics in electrical installations. These devices are essential for reducing electromagnetic disturbances, improving power factors, and ensuring the longevity and efficiency of electronic equipment.
Compensators:- C22D Compensator: Offers high filtering of 3rd, 5th, 7th, 9th, 15th, 17th, and 19th harmonics. It reduces neutral current and voltage distortion significantly, achieving a power factor of up to 0.80.
- C25D and C30D Compensators: These models provide galvanic isolation and high filtering capabilities, reducing neutral current and voltage distortion by up to 90% and achieving a power factor of up to 0.96.
- C10F and C20F Compensators: Designed for high filtering requirements, these models work best with RTL or RTLX line inductances, achieving a power factor of up to 0.98.
Inductances:- QR Series: Encapsulated inductances for single-phase lines, offering features like flame retardant resin encapsulation and resistance to current surges. They are suitable for damp, saline, or corrosive environments.
- R Series: Similar to the QR series but with copper connection terminals for enhanced safety and reliability.
- RTLX Series: Designed for three-phase installations, these inductances provide dual protection and are certified for safety and compliance.
Technical Features: The document includes detailed specifications for each model, including current ratings, dimensions, and mounting options. It also highlights the importance of using these devices in combination with other components like transformers and capacitors for optimal performance.
Applications: These devices are crucial for reducing harmonics in industrial and office installations, improving power quality, and protecting sensitive electronic equipment from disturbances.
Technical Specifications and Applications for Various Series of Inductances for Harmonic Filtering
The document provides detailed technical specifications and applications for various series of inductances used for harmonic filtering in three-phase lines. These include the RTLX, RTOX, FTOX, and RTFX series, each designed for specific applications in electrical networks.
1. RTLX Series:- Purpose: Designed for harmonic filtering in three-phase installations with network voltages between 380 V and 460 V.
- Applications: Reduces current harmonics, improves power factor, and extends equipment life by reducing the crest factor of current waveforms.
- Features: Encapsulated in flame retardant resin, copper connection terminals, and resistance to current surges and mechanical vibrations.
- Technical Specifications: Operates at 50-60 Hz, with a protection rating of IP20 and a test voltage of 3 kV.
2. RTOX Series:- Purpose: Used for harmonic filtering at the converter output in three-phase lines with a network voltage of 400 V.
- Applications: Attenuates voltage peaks and reduces reflection effects, protecting motor dielectric elements.
- Features: Dual protection with resin and anti-flash varnish, thermal protection, and UL certification.
- Technical Specifications: Operates at 50-60 Hz, with a protection rating of IP00 and a test voltage of 3 kV.
3. FTOX Series:- Purpose: Inductances with a capacitor filter for harmonic filtering at the converter output, suitable for converter-motor distances greater than 30 m.
- Applications: Similar to RTOX, with additional suitability for longer cable lengths.
- Features: Dual protection, thermal protection, and UL certification.
- Technical Specifications: Operates at 50-60 Hz, with a protection rating of IP00 and a test voltage of 3 kV.
4. RTFX Series:- Purpose: Three-phase rejection inductances for capacitor batteries, designed to prevent resonances and protect against harmonics.
- Applications: Eliminates surge currents and overvoltage, protecting transformers and capacitor batteries.
- Features: Dual protection, thermal protection, and options for different filter factors.
- Technical Specifications: Operates at 50 Hz, with a protection rating of IP00 and a test voltage of 3 kV.
Conclusion: Each series is tailored for specific applications in harmonic filtering, offering various protective features and compliance with international standards. The document emphasizes the importance of these inductances in improving power quality and protecting electrical equipment.
Technical Specifications and Applications for Various Transformer Series
The document provides detailed technical specifications and applications for various series of transformers manufactured by POLYLUX, including PXR, PX, and TK series. These transformers are designed for voltage adaptation, galvanic isolation, and safety in both household and industrial environments.
PXR Series: - Designed for voltage adaptation in control and maneuver applications.
- Features include anti-flash dip varnishing, UL certification, and DIN rail mounting up to 250 VA.
- Technical specifications: Input/output voltage up to 750V, power rating from 40 VA to 1600 VA, and protection rating of IP00.
- Standards compliance: UL 5085-1/2, CSA C22.2, IEC/EN 61558.
PX Series: - Similar applications as PXR, with a broader power range from 25 VA to 5000 VA.
- Mounting with screws and compliance with similar standards as PXR.
- Features include anti-flash varnishing and UL certification.
TK Series: - Used for circuit isolation and voltage transformation, suitable for industrial, tertiary, or residential installations.
- Power range from 3.15 kVA to 50 kVA, with various protection ratings (IP00, IP20, IP23, IP54, IP65).
- Features include anti-flash varnishing, UL certification, and high resistance to environmental factors.
Key Features Across Models: - All models ensure galvanic isolation and safety voltage provision (<50V).
- Common features include anti-flash varnishing for insulation and noise reduction, UL certification, and compliance with international standards.
- Options for custom manufacturing and additional protections are available upon request.
Conclusion: POLYLUX transformers are versatile and compliant with multiple international standards, making them suitable for a wide range of applications in both household and industrial settings.
Technical Specifications and Features of Various Transformer Series
This document provides detailed specifications and features of single-phase and three-phase transformers manufactured by Polylux. It covers various models, their power ratings, protection ratings, and additional features.
Specifications:- Power Range: Single-phase transformers range from 2 kVA to 100 kVA, while three-phase transformers range from 0.63 kVA to 1000 kVA.
- Windings: Available in copper or aluminium.
- Frequency: Operates from 50 Hz to 400 Hz.
- IP Rating: Options include IP00, IP20, IP23, IP31, IP33, IP42, IP54, IP55, and IP65.
- IK Rating: IK08 and IK10.
- Room Temperature: Up to 60 ºC.
- Test Voltage: Up to 28 kV.
- Short Circuit Voltage: Ranges from 2% to 9%.
- Operation: Can be intermittent or continuous.
- Cooling: Natural or forced ventilation.
- Altitude: Up to 4000 m.
Features:- Protections: Available in both primary and secondary circuits.
- Temperature Sensors: Options include PT100, PTC, or bimetallic sensors.
- External Protection: Includes anti-flash varnish, resin encapsulation, and metal or stainless steel enclosures.
- Adjustment: Voltage adjustment options range from -10% to +10%.
- Certification: Certified by CE, DNV-GL, BV, UL, and Polylux laboratory.
Applications:- Isolation of circuits with voltage adjustment capabilities.
- Reduction of voltage drops in long cable installations.
- Improvement of electrical network quality in installations with electrical noise.
- Change of neutral system in installations.
Recommendations:- For economical installations, IP00 models can be used in dry places with necessary protections.
- Encapsulated models offer better properties, including fire retardant resin encapsulation.
- Transformers are designed for continuous operation and are protected against damp, saline, and corrosive environments.
Technical Features:- Insulation Class: Class F and H depending on the model.
- Noise Level: Generally ≤45 dB for lower power models and ≤65 dB for higher power models.
- Standards: Complies with UL, CSA, IEC/EN standards.
- Cooling: Options include AN (Air Natural) and ANAF (Air Natural Air Forced).
Technical Specifications and Features of Various Three-phase Transformers
The document provides detailed specifications and features of various three-phase transformers under the TT series by Polylux. It includes information on different models such as TTX, TTW, TTZ, TTE, and TTU, each designed for specific applications and power ratings.
Specifications: The transformers are categorized based on power ratings ranging from 0.63 kVA to 1000 kVA. Each model is detailed with external dimensions, fastening elements, weight, and specific features like IP ratings and insulation classes. The document also outlines the input and output voltages, typically 400 V + N.
Procedures and Standards: The document mentions compliance with various standards such as CE, DNV-GL, BV, UL, and IEC/EN 61558. It also highlights the manufacturing process, including the use of anti-flash varnish for insulation and noise reduction.
Recommendations: Recommendations for selecting the appropriate transformer based on installation location and use are provided. The document suggests considering factors like IP rating, cooling methods, and environmental conditions.
Key Features: Transformers are available with options for copper or aluminum windings, various IP and IK ratings, and different cooling methods. They are designed for continuous operation, with features like anti-condensation systems, temperature sensors, and anti-vibration systems.
Applications: The TTU series is highlighted for its use in isolating circuits and improving electrical network quality. It is suitable for installations with electrical noise and for changing the neutral system of an installation.
Additional Information: The document includes diagrams and figures illustrating technical features, electrical diagrams, and optional manufacturing features. It also provides contact information for further inquiries.
Technical Specifications and Features of the TTK Series of Three-phase Transformers
The document provides detailed specifications and features of the TTK series of three-phase transformers, designed for isolation from three-phase to single-phase with a 400 V input and 230 V output. It includes various models with different power ratings, dimensions, and technical features.
Specifications: The document lists multiple models under the TTK series, including TTKW, TTKX, and TTKZ, each with specific power ratings (kVA), dimensions, weight, and fastening elements. The transformers are available in different IP ratings, indicating their protection level against environmental factors.
Technical Features: The transformers are designed for continuous operation with options for natural or forced ventilation cooling. They include features like electrostatic shields, temperature sensors, and anti-condensation systems. The transformers are certified under various standards, including CE, DNV-GL, BV, and UL.
Applications: The TTK series transformers are suitable for circuit isolation, voltage adjustment, reducing voltage drops, improving electrical network quality, and energy savings in installations such as renewable energy plants.
Manufacturing Options: Customization options include different winding materials (copper or aluminum), frequency ranges (50 Hz to 400 Hz), and various protection and cooling systems. The transformers can be equipped with anti-vibration systems and are available with different paint classes for corrosion resistance.
Additional Information: The document includes diagrams and figures illustrating the connection units, terminal types, and other technical aspects. It also provides information on the ecological TTG series, which focuses on energy efficiency and environmental protection.
Technical Specifications and Features of Various Transformer Series for Solar Inverters and Single-phase Autotransformers
The document provides detailed specifications and features of various transformer series designed for solar inverters and single-phase autotransformers. It includes technical data, manufacturing options, and application guidelines for the TTF, TTFZ, PAU, and QAU series.
TTF Series: - Input: 800 V +N, Output: 400 V +N.
- Power range: 0.15 kVA to 1000 kVA.
- Voltage range: 1 V to 12 kV.
- Windings: Copper or aluminium.
- Frequency: 50 Hz to 400 Hz.
- IP ratings: IP00 to IP65.
- Features include low losses, ecological operation, and various cooling options.
TTFZ Series: - Designed for solar inverters with IP65 and IP54 ratings.
- Power range: 0.63 kVA to 1000 kVA.
- Includes features like anti-condensation systems and temperature control.
PAU Series: - Single-phase autotransformers for voltage changes between 400 V and 230 V.
- Power range: 100 VA to 12500 VA.
- Features include anti-flash varnishing, LED indicator lamp, and protective terminal covers.
QAU Series: - Encapsulated reversible autotransformers for voltage changes between 400 V and 230 V.
- Power range: 100 VA to 6500 VA.
- Includes features like increased wiring insulation and robust design.
General Features: - All transformers are checked for compliance with standards like IEC/EN/UNE-EN 61558.
- Options for custom manufacturing and additional accessories are available.
- Protection against damp, saline, and corrosive environments is provided.
AUR Series Overview
The AUR series consists of reversible single-phase autotransformers designed for voltage changes between 220V and 125V. These transformers are suitable for both industrial and household appliances with different voltage requirements. They feature epoxy resin-painted protective covers, male-to-male cables, and metal handles. The transformers are protected against indirect contacts and corrosion, with an IP20 rating to prevent direct electrical contact.
Technical Specifications
- Power range: Up to 1000 VA and from 1500 VA.
- Connection: Screw connection strip.
- Input/Output Voltage: 220V/125V.
- Protection: IP20 rating.
Manufacturing Characteristics
- Made in Spain.
- CE declaration of conformity.
- Designed for intermittent use (30 min/60 min).
AUT Series Overview
The AUT series includes reversible three-phase autotransformers for voltage changes between 400V and 230V. These transformers are designed for continuous operation at maximum output and are used in three-phase installations. They are dipped in anti-flash varnish for increased insulation, reduced noise, and moisture protection.
Technical Specifications
- Power range: 1 kVA to 1000 kVA.
- Protection: IP23 rating (IK08), IP65 up to 80 kVA, IP54 from 100 kVA (IK10).
- Insulation Class: Class H - 180 ºC.
- Standards: UL certification, IEC/EN 61558, IEC/EN 60076.
- Cooling: AN (AUTX), ANAN (AUTW/AUTZ IP65), ANAF (1000kVA AUTW/AUTZ IP54).
Manufacturing Characteristics
- Metal box painted with RAL7035 polyester resin.
- High resistance to corrosion.
- Detachable top and front cover.
- Hoisting elements included.
Terminal and Connection Details
- Various terminal types and power strips are available for different power ratings.
- Maximum tightening torque and conductor cross-section details are provided for each model.
Measurements and Weight
Detailed measurements and weight specifications are provided for each model in the AUR and AUT series, ensuring proper installation and handling.
Technical Specifications and Features of the AUTF Series Autotransformers
The document provides detailed technical specifications and features of the AUTF series autotransformers designed for solar inverters. These transformers are used to adjust the output voltage of inverters from 800V to 400V, meeting customer requirements.
Specifications: The AUTF series includes models with power ratings from 1 kVA to 2000 kVA. They operate at standard voltages of 800 V / 400 V and frequencies of 50-60 Hz. The transformers are available in different insulation classes (Class F and Class H) and are designed for continuous operation with various cooling methods (AN, ANAN, ANAF).
Construction and Features: The transformers are constructed with high-resistance materials, including metal boxes painted with RAL7035 polyester resin for corrosion resistance. They feature anti-flash varnish for enhanced insulation, noise reduction, and moisture protection. The transformers are available with different IP ratings (IP00, IP23, IP65, IP54) and IK ratings (IK08, IK10) depending on the model.
Standards and Compliance: The transformers comply with IEC/EN 61558 and IEC/EN 60076 standards, with CE declarations of conformity. They are tested for a voltage of 3 kV for one minute at 50 Hz.
Technical Data: The document includes detailed tables listing the power, reference, insulation class, current intensity, protection ratings, noise levels, and dimensions for each model. It also provides information on terminal types, maximum conductor cross-sections, and tightening torques.
Manufacturing Options: Custom manufacturing options are available on request, including different winding materials (copper or aluminum), voltage ranges (1 V to 12 kV), and frequency adjustments.
Figures and Diagrams: The document contains electrical diagrams and figures illustrating the dimensions and configurations of the transformers for various power ratings.
Technical Specifications and Features of Various Electrical Equipment
The document provides detailed technical specifications and features of various electrical equipment, including autotransformers, voltage regulators, and stabilizers, primarily used in solar inverters and industrial applications. It outlines the operational parameters, protection ratings, and manufacturing standards for these devices.
1. Autotransformers (AUTF SERIES):- Designed for voltage changes from 800 V to 400 V.
- Features include multiple IP and IK ratings, operation modes (intermittent, continuous), and cooling methods (natural, forced ventilation).
- Equipped with temperature sensors (PT100, PTC, bimetallic) and anti-condensation systems.
- Certified by CE, DNV-GL, BV, UL, and POLYLUX laboratory.
2. Voltage Regulators (REGM SERIES):- Bidirectional single-phase regulators with input and output of 230 V.
- Designed to prevent inverter shutdowns in photovoltaic installations by regulating grid fluctuations.
- Features include magneto-thermal protection, high-tech grid monitoring, and a TFT screen for visual evaluation.
- IP65 rated, noise level ≤ 25 dB, and maintenance-free.
3. Voltage Stabilizers (VK and VTF SERIES):- VK Series: Single-phase stabilizers with input 230 V ± 20% and output 230 V ± 1%.
- VTF Series: Three-phase stabilizers with input 400 V+N ± 20% and output 400 V+N ± 1%.
- Both series include built-in BY-PASS, automatic control, and various protections against over temperatures, short circuits, and overloads.
- Manufactured to comply with IEC/EN/UNE standards and offer high performance (>98%).
4. Transformer Rectifiers:- Used for applications requiring DC power supply, such as industrial automation and battery charging systems.
- Available in single-phase and three-phase configurations with customizable options.
- Protection ratings range from IP00 to IP65, with cooling options including AN, ANAN, and ANAF.
5. Controlled Transformer Rectifiers:- Designed for high DC power processes like chemical electrolysis and surface treatment.
- Features include voltage and current control, galvanic isolation, and thermal protections.
- Configured with SCR primary control and B6U rectifier, adhering to IEC/EN/UNE standards.
6. Special Fabrications:- Polylux offers custom-engineered products to meet specific voltage, power, and environmental requirements.
- Capabilities include single and three-phase encapsulated transformers with voltages up to 12 kV and powers up to 1000 kVA.
7. IP Ratings:- Detailed descriptions of various IP ratings, from IP00 (no protection) to IP65 (full protection against dust and water jets).
Technical Specifications and Guidelines for Selecting and Using Transformers
The document provides technical specifications and guidelines for selecting and using transformers, particularly focusing on their resistance to transient surge currents and harmonics. It includes information on various types of transformers, their applications, and protection measures.
Specifications: The document outlines different types of transformers, including isolation, control, safety, and medical transformers, as well as ecological equipment with high performance and low losses. It also covers three-phase and single-phase autotransformers, and transformers for harmonic networks.
Protection and Safety: The document emphasizes protection from dust and water, and includes equipment for clinical electrical installations. It provides symbols for different transformer types and their applications.
Temperature and Insulation: A table is provided for temperature increase according to EN61558 / EN60076 standards, detailing class and maximum temperature specifications for different insulation classes (B, F, H).
Connection Units: Various connection configurations are detailed, including YNd, Dzn, and Yzn types, with diagrams illustrating the connections.
Conductor and Protection Selection: Guidelines for selecting conductors and protections for low power single-phase transformers are provided. The document includes tables for calculating maximum currents and selecting appropriate conductors and protections based on power and voltage.
High Power Transformer Protection: Similar guidelines are provided for high power single-phase and three-phase transformers, with tables for selecting input and output protections based on maximum current calculations.
Examples: The document includes examples for calculating input and output protections for both single-phase and three-phase transformers, illustrating the application of the provided tables.
Contact Information: The document concludes with contact information for Polylux, including their address in Barcelona, Spain, and contact numbers for local and international inquiries.