Introduction
The document provides an overview of Pollrich DLK Fan Factories' centrifugal fans, focusing on direct-driven models. It highlights the company's experience in manufacturing industrial fans and their commitment to quality and customer satisfaction.
Product Specifications
The document details the type code for centrifugal fans, including categories such as compact, plug, and smoke extraction fans. It specifies nominal diameter, impeller-diameter ratio, and drive types, emphasizing versatility and customization for industrial needs.
Sound Calculations
This section explains sound pressure and sound power levels, including calculation and measurement methods. It discusses the importance of sound pressure levels in various environments and provides examples.
Project Planning Advice
Guidance is offered on planning projects involving centrifugal fans, including explosion protection advice. It explains classifications and protection types required for fans in explosive environments, complying with Directive 94/9/EC.
Explosion Protection
The document outlines compliance requirements for fans in explosive environments, detailing device groups, zone divisions, protection types, and temperature classes, with reference tables.
Similarity Laws
This section discusses similarity laws for converting measuring data under changed conditions, ensuring machines with geometric similarity can have their operating data mutually converted.
Specifications and Conversion Factors
The document discusses converting geometric dimensions in fans, emphasizing consistent angles across similar machines. It outlines formulas for converting volume flow, pressure increase, and shaft output based on changes in impeller diameter, speed, and fluid density.
System Characteristics and Performance Curves
The system characteristic describes pressure loss influenced by flow medium density, speed, and loss coefficients. Fan characteristics are measured under standardized conditions, with the operating point determined by the intersection of system and fan characteristics.
Installation and Operating Advice
Proper installation requires ensuring disturbance-free inflow and outflow, with adequate distance between the fan and fittings for optimal performance.
Units and Conversion Factors
The document provides conversion factors for various units of length, angle, and pressure, including tables for converting between different pressure units.
Product Information
The document details Pollrich DLK's centrifugal fans, highlighting features such as aerodynamically optimized impellers, a wide range of accessories, and robust design. It specifies permissible flow temperatures and casing materials, with options for corrosion protection and custom motor specifications.
Performance and Installation
Performance curves show the relationship between pressure increase and volume flow. Installation options include various casing positions, with fans available under ATEX directives. Accessories and tender specifications are available on the company's website.
Specifications
  • Motor Power Output: Ranges from 2.2 kW to 160 kW depending on the model.
  • Speed: Varies from 730 to 2965 rpm.
  • Voltage: All models operate at 400/690 volts with a delta/star (∆/Y) connection.
  • Current: Nominal current ranges from 4.6 A to 157 A, with starting currents significantly higher.
  • Weight: The weight of the fans varies from 146 kg to 1928 kg.
  • Dimensions: Dimensions are provided for each model, including height, width, and length.
Accessories
The document lists various accessories with their order numbers, such as protective grills, flexible sleeves, anti-vibration mounts, flanges, inspection hatches, and condensate drains.
Performance Data
Graphs and tables provide performance data, including efficiency, power range, and airflow in cubic meters per hour. Efficiency percentages range from 61.3% to 86.6%.
Additional Notes
All values are indicated for 400 V/50 Hz/3~. The casing position is specified as 0°, 90°, or 270° for different models.
Procedures and Standards
The fans are tested according to DIN 24163 and ISO 5801 standards for air performance, ensuring accuracy and reliability. Compliance with ATEX 94/9/EG Directive is mentioned for certain models.
Recommendations
The document suggests using these fans for various applications due to their high efficiency, robust design, and easy installation. It highlights the importance of adhering to specified operating conditions and maintenance practices for optimal performance.
Key Data from Tables and Graphs
The document includes tables listing order numbers, dimensions, and weights of fan models. Graphs illustrate the relationship between flow rate and static pressure increase, providing visual insights into fan performance under different conditions.
Critical Information
The document emphasizes the importance of selecting the right fan model based on specific application requirements, considering factors such as flow rate, pressure, and environmental conditions. It advises on the use of appropriate accessories to prevent issues like impact sound transmission and condensate accumulation.
Service and Support
Pollrich DLK offers comprehensive service support, including technical advice, assembly, commissioning, performance tests, noise and vibration measurements, inspection, preventative maintenance, repair, electronic balancing, and system optimization. The service team is available around the clock.
See more

Catalog excerpts

Centrifugal fans Direct Driven-1

Centrifugal fans direct driven

 Open the catalog to page 1
Centrifugal fans Direct Driven-2

Type code and symbols Type code for centrifugal fans P = Plug fan = Thermoplug "* Pol">ch DLK Type code of all products H_Centrifugal fan (heavy-duty) A_Axial 0_Without guide vanes M_Motor C_Centrifugal fan (compact) R_Centrifugal N_Outlet guide vanes K_Coupling A_Axial fan V_Inlet guide vanes R Belt drive S_Smoke extraction fan E_Single inlet Z_Double inlet G_Car park LW(A) Sound power level A-weighted

 Open the catalog to page 2
Centrifugal fans Direct Driven-4

PRODUCTS PLUS FULL-SERVICE five u The Trademark Pollrich DLK Fan Factories® The common trademark “Pollrich DLK Fan Factories” pools more than 140 years of production knowhow of industrial fans by the manufacturers Pollrich Ventilatoren GmbH and DLK Ventilatoren GmbH. A workforce of more than 220 employees at the two production sites Mönchengladbach and SchöntalBerlichingen manufacture axial and centrifugal fans for nearly any industrial requirement. As the only manufacturer in the world offering all five product segments of industrial fans, we propose an unmatched range of products for the most...

 Open the catalog to page 4
Centrifugal fans Direct Driven-5

Our R&D department combines expertise within all sectors of fan technology with highly efficient simulation tools such as CFD (Computational Fluid Dynamics) for flow visualisation and FEM (Finite-Element-Method) to calculate the structure-mechanical characteristics, as well as test ducts and -chambers according to international standard ISO 5801, equipped with the latest measuring technology in order to determine the aerodynamic and aeroacoustic characteristics. We take care of you, wherever you are in the world, with our comprehensive power service package beginning at the moment of feasibility...

 Open the catalog to page 5
Centrifugal fans Direct Driven-6

Project planning advice Theoretical principles Sound pressure Sound pressure waves are small pressure fluctuations that are masked by the ambient pressure. Due to the fact that the sound pressure in the normal pressure unit Pa exceeds several powers of 10, it is usually stated as the sound pressure level in a logarithmic form in the unit decibel [dB]: (1) p2 Lp = 10 ⋅ lg eff p2 o A sound pressure level of e.g. 8 dB therefore corresponds to 108/10 times the lower hearing threshold. This correlation is shown by the examples in Table 1 Table 1: Correlation between the sound pressure and sound pressure...

 Open the catalog to page 6
Centrifugal fans Direct Driven-7

Project planning advice The enveloping surface unit is determined in (6) as follows: (6) A LS = 10 ⋅ lg mit A0 = 1m 2 A0 The k octave bands can be summarised to a total sound power level LW, tot by means of logarithmic addition for all mean frequencies: (7) LW ,i k LW,ges = 10 ⋅ lg ∑ 10 10 i =1 A-weighting The A-weighting is a relativisation that takes into account the characteristics of the human ear (unit dB(A)). To determine an A-weighted octave spectrum, the level corrections shown in Table 2 are added to the non-weighted spectrum: (8) Comments To calculate the sum of several sound sources,...

 Open the catalog to page 7
Centrifugal fans Direct Driven-8

Project planning advice Explosion protection Types of protection The type of protection shows the technical action taken to ensure the machine cannot act as an ignition source. Table 5 shows what action can be taken so that nonelectrical components can be used in explosion-protection areas acc. to EN 13463-1 ff (non-electric). Fans may only be used in areas in which there may be explosive media if they have been manufactured in compliance with the Directive 94/9/EC. The principles of this Directive are shown below. Theoretical principles Apart from the CE ( ) and the so-called ATEX symbol ( )...

 Open the catalog to page 8
Centrifugal fans Direct Driven-9

Project planning advice The temperature classes are selected like the classification of the explosion protection types depending on the material used and are also stated in the Directive 94/9/ EC or corresponding tables. Identification in dusty atmosphere When fans are used in a dusty atmosphere the identification has to be changed. The explosion protection group is not used anymore. The temperature class is replaced by the maximum surface temperature. Similarity laws This section looks at the similarity laws that serve the conversion of the measuring data for changed operating conditions. If...

 Open the catalog to page 9
Centrifugal fans Direct Driven-10

Project planning advice Systemcharacteristic Performance curve Operating point Radian Angles can either be stated in radians (angle in relation to p ) or in degrees.180° degree correspond to a radian of p . Important radians are shown inTable 9. Table 9: Conversion radian and degrees qv [m3/h] Figure 7: Operating point as the intersection of the system and performance curves Ignored or inadequately considered influences that change the system pressure loss and therefore change the flow behaviour lead to a change in the system characteristic and therefore also shift the operating point. Also,...

 Open the catalog to page 10
Centrifugal fans Direct Driven-11

Characteristic Determination: Example: 1. Desired duty point qv = 9000 m³/h; pf = 6500 Pa. 2. Select performance that is above the duty point. Example 22 kW. 3. Input the selected motor power and read the corresponding order number from the table. Here this is: B100842 4. Use inverter drive if the duty point is not close to a standard rotational speed. Motor power output [kW]

 Open the catalog to page 11
Centrifugal fans Direct Driven-12

Compact centrifugal fans, direct driven diameter relationship / diameter Power range on request 10000 Plug fans, direct driven Product Serie PREM01 71 / 400-1120 Static fan pressure psf [Pa] diameter relationship / diameter

 Open the catalog to page 12
Centrifugal fans Direct Driven-13

s al fandriven g entrifu nd belt C a clutch- ... you should get to know! Pollrich DLK Fan Factories

 Open the catalog to page 13
Centrifugal fans Direct Driven-14

Product-specic information CENTRIFUGAL FAN CREM 28-71 / 400-1400 Application: The direct driven compact centrifugal fans of product group CREM (Etatec by Pollrich DLK) can be used for extraction and supply of clean and slightly dusty air for various applications. The main advantages: - Aerodynamically optimized impellers - Wide range of accessories - High efciency through wide product portfolio with 9 variants per impeller diameter - Compact design - Robust design - Easy installation - Large increases in pressure as well as high volume ows - Customized solutions Air performance curves: Show the...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.