Catalogue axial smoke extraction fans Toromax, ToromaxPro
120Pages

{{requestButtons}}

Catalog excerpts

Catalogue axial smoke extraction fans Toromax, ToromaxPro - 1

Smoke extraction fans

Open the catalog to page 1
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 2

Type code Type code for smoke extraction fans 7. Basic series Ø Nominal impeller diameter DN [mm] 6. 5. Product specific code 02 = Temperature class F200 03 = Temperature class F300 04 = Temperature class F400 06 = Temperature class F600 4. Drive R = Belt drive 3. Type of construction DLK O = Without guide vanes = Toromax by Pollrich DLK N = Outlet guide vanes = ToromaxPro by Pollrich G = Car park = ToromaxPro duplex by Pollrich DLK V = Inlet guide vanes = Supermax by Pollrich DLK Pollrich DLK D = Roof = SanmaxPro by Pollrich DLK, Santec by E = Single inlet = Etatec by Pollrich DLK W Wall =...

Open the catalog to page 2
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 4

PRODUCTS PLUS FULL-SERVICE five u The Trademark Pollrich DLK Fan Factories® The common trademark “Pollrich DLK Fan Factories” pools more than 140 years of production knowhow of industrial fans by the manufacturers Pollrich Ventilatoren GmbH and DLK Ventilatoren GmbH. A workforce of more than 220 employees at the two production sites Mönchengladbach and SchöntalBerlichingen manufacture axial and centrifugal fans for nearly any industrial requirement. As the only manufacturer in the world offering all five product segments of industrial fans, we propose an unmatched range of products for the...

Open the catalog to page 4
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 5

Our R&D department combines expertise within all sectors of fan technology with highly efficient simulation tools such as CFD (Computational Fluid Dynamics) for flow visualisation and FEM (Finite-Element-Method) to calculate the structure-mechanical characteristics, as well as test ducts and -chambers according to international standard ISO 5801, equipped with the latest measuring technology in order to determine the aerodynamic and aeroacoustic characteristics. We take care of you, wherever you are in the world, with our comprehensive power service package beginning at the moment of...

Open the catalog to page 5
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 6

Project planning advice Theoretical principles Sound pressure Sound pressure waves are small pressure fluctuations that are masked by the ambient pressure. Due to the fact that the sound pressure in the normal pressure unit Pa exceeds several powers of 10, it is usually stated as the sound pressure level in a logarithmic form in the unit decibel [dB]: (1) p2 Lp = 10 ⋅ lg eff p2 o A sound pressure level of e.g. 8 dB therefore corresponds to 108/10 times the lower hearing threshold. This correlation is shown by the examples in Table 1 Table 1: Correlation between the sound pressure and sound...

Open the catalog to page 6
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 7

Project planning advice The enveloping surface unit is determined in (6) as follows: (6) A LS = 10 ⋅ lg mit A0 = 1m 2 A0 The k octave bands can be summarised to a total sound power level LW, tot by means of logarithmic addition for all mean frequencies: (7) LW ,i k LW,ges = 10 ⋅ lg ∑ 10 10 i =1 A-weighting The A-weighting is a relativisation that takes into account the characteristics of the human ear (unit dB(A)). To determine an A-weighted octave spectrum, the level corrections shown in Table 2 are added to the non-weighted spectrum: (8) Comments To calculate the sum of several sound...

Open the catalog to page 7
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 8

Project planning advice Explosion protection Types of protection The type of protection shows the technical action taken to ensure the machine cannot act as an ignition source. Table 5 shows what action can be taken so that nonelectrical components can be used in explosion-protection areas acc. to EN 13463-1 ff (non-electric). Fans may only be used in areas in which there may be explosive media if they have been manufactured in compliance with the Directive 94/9/EC. The principles of this Directive are shown below. Theoretical principles Apart from the CE ( ) and the so-called ATEX symbol (...

Open the catalog to page 8
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 9

Project planning advice The temperature classes are selected like the classification of the explosion protection types depending on the material used and are also stated in the Directive 94/9/ EC or corresponding tables. Identification in dusty atmosphere When fans are used in a dusty atmosphere the identification has to be changed. The explosion protection group is not used anymore. The temperature class is replaced by the maximum surface temperature. Similarity laws This section looks at the similarity laws that serve the conversion of the measuring data for changed operating conditions....

Open the catalog to page 9
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 10

Project planning advice Systemcharacteristic Performance curve Operating point Radian Angles can either be stated in radians (angle in relation to p ) or in degrees.180° degree correspond to a radian of p . Important radians are shown inTable 9. Table 9: Conversion radian and degrees qv [m3/h] Figure 7: Operating point as the intersection of the system and performance curves Ignored or inadequately considered influences that change the system pressure loss and therefore change the flow behaviour lead to a change in the system characteristic and therefore also shift the operating point....

Open the catalog to page 10
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 11

Blade angle Performance curve representation: 104 102 According to ISO 5801, the total pressure increase of the fan with pressure side duct 2000 connection (L,min ≥ 2,5 x DN fan) corresponds to the effective pressure of the fan. The effective pressure is the pressure, which is pressure loss of the system. available to overcome the X *If motor excess length is > 0, a duct extension (Z11) is required to assemble accessories Z07, Z20. Example: Requested operating point 11450 m³/h by Pollri 3 kW. 12xø11,5at 400 Pa, static => motor power needed: Toromax Blade angle: 26° (to be specified when...

Open the catalog to page 11
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 12

Comparison of the axial fans Product Series SAOM03 DN/Poles [Pa] 1800 Total pressure increase pf [Pa] 2800 2600 2400 Total pressure increase pf [Pa] Total pressure increase pf [Pa]

Open the catalog to page 12
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 13

Comparison of the axial fans Product Series SAGM03 5600 5200 4800 Totale Druckerhöhung pf [Pa] 3200 Total pressure increase pf [Pa] Total pressure increase pf [Pa]

Open the catalog to page 13
Catalogue axial smoke extraction fans Toromax, ToromaxPro - 14

Product-specific information Low pressure axial fan SAOM The axial smoke extraction fans of Pollrich DLK Fan Factories are the result of intensive cooperation with well-known research institutions, the use of the latest tools for product development (CFD, FEM,..) and million investments in up-to-date manufacturing technology. The new series combines best price and optimal efficiencies. All fans are equipped as standard with motors according to energy efficiency class IE2 and exceed the efficiency standards of the ErP-directive for 2013 (ecodesign directive). Range of application: The low...

Open the catalog to page 14