SOLENOID VALVES OPTYMA-Sc COMPACT DESIGN
Open the catalog to page 1Solenoid valves manifold Optyma solenoid valves series comes completed by "Compact" version, useful when a limited number of solenoid valves is needed without managing input and output signals. Standard base blocks provide 4 or 6 solenoid valves positions. Standard base blocks can be individually sold even without solenoid valves to allow maximum configuration flexibility. Solenoid valves can be chosen from whole Opytma-S range. Manifolds made in this way allow great room and weight saving against corrispondent pneumatic group from Optyma-S series. - Flow rate: up to 550[Nl/min], using the modular...
Open the catalog to page 3Solenoid valves manifold Series 2200 "Optyma-Sc" - Configurator Rules and configuration scheme C- CONFIGURATION CODE Multi-pin 9 poles PNP connector Multi-pin 15 poles PNP connector Multi-pin 9 poles NPN connector Multi-pin 15 poles NPN connector Multi-pin 9 poles AC connector Multi-pin 15 poles AC connector External feeding See “single pneumatic module configurator” Diaphragm plug (optional) X Diaphragm plug on port 1 Diaphragm plug on port 3 Diaphragm plug on port 5 See “single pneumatic module configurator” Diaphragm plug (optional) only for 15 poles connector Diaphragm plug on port 1 Diaphragm...
Open the catalog to page 4Solenoid valves manifold Series 2200 "Optyma-Sc" - Configurator Only base configuration example: C-MP1-E-6VV-6VV-6VV-P0 Standard configuration example: C-MP1-E-6AA-6CF-6FF-P1 15 poles multi-pin connection Standard left endplate Bistable standard base Ø6 without solenoid valves (6VV) Bistable standard base Ø6 without solenoid valves (6VV) Bistable standard base Ø6 without solenoid valves (6VV) Right Endplates closed 15 poles multi-pin connection Standard left endplate Bistable standard base Ø6 with AA type solenoid valves (6AA) Bistable standard base Ø6 with CF type solenoid valves (6CF) Bistable...
Open the catalog to page 5Solenoid valves manifold Series 2200 "Optyma-Sc" - Installation specifications Manual override actuation Instable function: Push to actuate (when released it moves back to the original position) Bistable function: Push and turn to get the bistable function Note: we recommend the manual override is returned to it’s original position when not in use Solenoid valves installation Note: Torque moment 0,8 Nm Sub-base assembly Minimum torque moment: 2 Nm Maximum fixing torque for fittings: 2,5 Nm Overall dimensions and technical information are provided solely for informative purposes and may be modified...
Open the catalog to page 6Solenoid valves manifold Solenoid-Spring Technical characteristics Filtered air. No lubrication needed, if applied it shall be continuous Pilot pressure (bar) Temperature °C Flow rate at 6 bar with Δp=1 (Nl/min) SHORT FUNCTION CODE "A" with modular base, tube ø4 with modular base, tube ø6 with modular base, tube ø8 Response time according to ISO 12238, activation time (ms) Response time according to ISO 12238, deactivation time (ms) Solenoid-Differential Technical characteristics Filtered air. No lubrication needed, if applied it shall be continuous Pilot pressure (bar) Temperature °C Flow rate...
Open the catalog to page 7Solenoid valves manifold Series 2200 "Optyma-Sc" Solenoid-Solenoid 5/3 (Closed centres) Technical characteristics Filtered air. No lubrication needed, if applied it shall be continuous Pilot pressure (bar) Temperature °C SHORT FUNCTION CODE "E" with modular base, tube ø4 with modular base, tube ø6 with modular base, tube ø8 Response time according to ISO 12238, activation time (ms) Response time according to ISO 12238, deactivation time (ms) Solenoid-Solenoid 2x3/2 Technical characteristics FUNCTION 44 = NC-NC (5/3 Open centres) Filtered air. No lubrication needed, if applied it shall be continuous...
Open the catalog to page 8Solenoid valves manifold Left Endplate Technical characteristics Filtered air. No lubrication needed, if applied it shall be continuous 15 = 15 poles multi-pin connection 09 = 9 poles multi-pin connection PORT 12/14 SEPARED FROM PORT 1. DO NOT PRESSURIZE PORT 82/84. PILOTS EXHAUST. Weight 199 g Ø8.2 PORT 12/14 SEPARED FROM PORT 1. DO NOT PRESSURIZE PORT 82/84. PILOTS EXHAUST. Weight 199 g 51.7 Right Endplate Technical characteristics Filtered air. No lubrication needed, if applied it shall be continuous 00 = Blind plate 03 = With alimentation/exhaust ports PORT 12/14 SEPARED FROM PORT 1. DO NOT...
Open the catalog to page 9Solenoid valves manifold Series 2200 "Optyma-Sc" Modular base (2 places) Technical characteristics TUBE DIAMETER Filtered air. No lubrication needed, if applied it shall be continuous 4 = Ø4 6 = Ø6 8 = Ø8 FUNCTION 01 = Opened ports 03 = Ports 1-5 separated 08 = Ports 3-5 separated 09 = Port 3 separated Individual supply or exhaust module Technical characteristics Filtered air. No lubrication needed, if applied it shall be continuous The flow rate of the solenoid valve will be reduced compared to that shown in the general catalogue SEPARATED SUPPLY SEPARATED SUPPLY 01 = Port 1 separated 35 = Ports...
Open the catalog to page 10Solenoid valves manifold Series 2200 "Optyma-Sc" - Accessories Diaphragm plug 04 = L 60mm (4 positions manifold) 06 = L 60mm (6 positions manifold) L 60mm (4 positions manifold) + 25mm (6 positions manifold) Cable complete with connector, 9 Poles, IP40 Coding: 2400.09.L.00 CABLE LENGTH 03 = 3 meters 05 = 5 meters 10 = 10 meters Cable complete with connector, 15 Poles, IP40 Coding: 2400.15.L.00 CABLE LENGTH 03 = 3 meters 05 = 5 meters 10 = 10 meters Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice
Open the catalog to page 11Via Cascina Barbellina, 10 24050 Lurano (BG) - Italy P. +39 035 41 92 777 [email protected]
Open the catalog to page 1370 Pages
140 Pages
164 Pages
1096 Pages
240 Pages
8 Pages
8 Pages
19 Pages
8 Pages
12 Pages
26 Pages
170 Pages
20 Pages
38 Pages
36 Pages
28 Pages
8 Pages
19 Pages
8 Pages
26 Pages