Introduction
Pneumax S.p.A., founded in 1976, specializes in automation components and systems, integrating pneumatic technology with electric drive actuators and fluid control components. The company is divided into three business units: Industrial Automation, Process Automation, and Automotive, providing customized solutions for diverse applications.
Series PX Overview
The Series PX is a modular electronic system for controlling pneumatic and electric devices, supporting multiple communication protocols and configurable with digital and analog I/O modules. It is compact, lightweight, and made from technopolymer, offering flexibility and ease of configuration.
Communication Protocols
The Series PX supports several communication protocols, including CANopen®, PROFIBUS DP, EtherNet/IP, EtherCAT®, PROFINET IO RT, and IO-Link. Each protocol node kit has specific technical characteristics and current limitations, ensuring compatibility with various industrial applications.
Inputs and Outputs Modules
The system includes various input and output modules, such as 8 and 32 digital inputs and outputs module kits, analog inputs and outputs module kits, and Pt100 inputs module kit, allowing extensive customization and integration with existing systems.
Configuration and Accessories
The Series PX can be configured using the Cadenas platform, with examples for different module combinations. Accessories include endplate kits, DIN rail adapters, and cables with connectors, facilitating easy assembly and integration.
Module Assembly Instructions
Instructions are provided for assembling the modules, including the use of endplate kits and DIN rail adapters. The system can be integrated with various valve manifold series, such as Optyma S, Optyma F, Optyma T, and Series 2700.
Technical Specifications
Each protocol node kit has detailed technical specifications, including power supply requirements, communication details, and protection degrees. The nodes manage a specific number of inputs and outputs, with current limitations outlined for safe operation.
Specifications
Each protocol node kit manages 128 inputs and outputs, with specific configurations for solenoid valve positions and additional modules. The document specifies the maximum deliverable current for outputs and inputs, emphasizing a 4 A limit for each fieldbus node. Exceeding this limit requires the use of a power supply module K5030.M12.
Technical Characteristics
The nodes operate at a voltage of +24 V DC ± 10%, with a node-only current consumption of 65 mA for inputs. They feature IP65 protection when assembled and operate within a temperature range of -5 to +50°C. Communication is facilitated through M12 connectors, with a maximum distance of 100 m between nodes.
Current Limitations
The document outlines the formula for calculating maximum current on outputs, considering the number of installed modules and solenoid pilots. It provides specific current values for different solenoid series, such as "Optyma s" and "Optyma F".
Digital Input/Output Modules
The document describes M8 and M12 digital input and output modules, detailing their connection types, logic, and power supply requirements. Each module has specific current limits and protection features, such as overcurrent and reverse polarity protection.
Connection and Configuration
The document provides detailed pin configurations for network and power supply connectors, emphasizing the importance of adhering to specified current limits and using appropriate power supply modules when necessary.
Technical Specifications
  • Power Supply Module: The K5030.M12 module provides additional power for downstream modules, using an M12 4-pin connector with separate pins for logic/inputs and outputs. Power presence is indicated by green LEDs.
  • Digital Inputs Module: Supports 32 digital inputs with PnP logic and a 24 V DC power supply, featuring overcurrent and reverse polarity protection, with a maximum current of 1 A and a cable length limit of 30 m.
  • Digital Outputs Module: Supports 32 digital outputs with PnP logic and a 24 V DC power supply, with short circuit protection, a maximum current of 100 mA per output, and a cable length limit of 30 m.
  • Analogue Inputs Module: Available in 2 or 4 channels, it converts analogue signals to digital with a 12-bit resolution, supporting voltage and current inputs with a maximum cable length of 30 m.
  • Analogue Outputs Module: Converts digital data to analogue signals with a 12-bit resolution, supporting voltage and current outputs with a maximum cable length of 30 m.
  • Pt100 Inputs Module: Digitizes signals from Pt100 probes with a 12-bit resolution, supporting 2, 3, or 4 wire probes with a temperature range of -100°C to +300°C.
Connectors
  • M12A 4P Female: Used for power supply connections.
  • M12A 5P Male/Female: Used for CANopen® and DeviceNet/IOLink connections.
  • M12D 4P Male: Used for EtherCAT®/PROFINET IO RT and Ethernet/IP connections.
  • M12B 5P Male/Female: Used for PROFIBUS DP connections.
  • M8 3P Male: Used for input module connections.
Signal Management
  • 64 Input/Output Systems: Supports 32 fixed outputs with options for PROFIBUS DP and CANopen®.
  • 128 Input/Output Systems: Supports 48 fixed outputs with options for EtherNet/IP, EtherCAT®, and PROFINET IO RT.
Additional Information
All technical information and dimensions are provided for informational purposes and may change without notice. For more details, visit Pneumax S.p.A.'s website.
See more

Catalog excerpts

MULTIPROTOCOL MODULE - SERIES PX-1

MULTIPROTOCOL MODULE - SERIES PX

 Open the catalog to page 1
MULTIPROTOCOL MODULE - SERIES PX-3

Solenoid valves manifold Series PX Smart Technologies and Human Competence Founded in 1976, Pneumax S.p.A. is today one of the leading, international manufacturers of components and systems for automation. It is at the fore front of a group comprised of 27 companies, with over 800 employees worldwide. Ongoing investment in research and development has allowed Pneumax to continually expand its range of standard products and customised solutions, adding to the well-established pneumatic technology, a range of electric drive actuators and fluid control components. The desire to provide the service...

 Open the catalog to page 3
MULTIPROTOCOL MODULE - SERIES PX-4

Solenoid valves manifold Multiprotocol module - Series PX Introduction Configuration examples Module assembly instructions Serial systems CANopen® protocol node kit. PROFIBUS DP protocol node kit EtherNet/IP protocol node kit EtherCAT® protocol node kit PROFINET IO RT protocol node kit IO-Link protocol interface kit Inputs and outputs modules 8 digital inputs module kits M8 & M12 8 digital outputs module kits M8 & M12 32 digital inputs and 32 digital outputs module kits (37 pin SUB-D connector) Analogue inputs module kit M8 Analogue outputs module kit M8 Additional modules Signal management Overall...

 Open the catalog to page 4
MULTIPROTOCOL MODULE - SERIES PX-5

Solenoid valves manifold Series PX SERIES PX MODULAR ELECTRONIC SYSTEM FLEXIBILITY IN A COMPACT SPACE • Maximum flexibility • Digital and analogue I/O modules • Stand alone solution connectable via SUB-D cable to all manifolds • Manufactured in technopolymer • Wide range of communication protocols Series PX modular electronic system has been designed to offer control and acquisition hardware for pneumatic and electric devices; it supports the most diffused communication protocols and can be configured with I/O modules, both digital and analog. Series PX in stand alone version can be connected...

 Open the catalog to page 5
MULTIPROTOCOL MODULE - SERIES PX-6

Solenoid valves manifold Endplates accessories Without DIN rail adapter With DIN rail adapter CANopen® node 64 IN - 64 OUT (32 fixed) CANopen® node 64 IN - 64 OUT (48 fixed) PROFIBUS DP node 64 IN - 64 OUT (32 fixed) PROFIBUS DP node 64 IN - 64 OUT (48 fixed) EtherNet/IP node 128 IN - 128 OUT (48 fixed) EtherCAT® node 128 IN - 128 OUT (48 fixed) PROFINET IO RT node 128 IN - 128 OUT (48 fixed) IO-Link protocol interface 64 IN - 64 OUT (32 fixed) IO-Link protocol interface 64 IN - 64 OUT (48 fixed) SINGLE MODULE CONFIGURATION Electric connection accessories Without DIN rail adapter G With DIN rail...

 Open the catalog to page 6
MULTIPROTOCOL MODULE - SERIES PX-7

Solenoid valves manifold Series PX - Configuration examples Configuration examples Example shown: PX3-P-N4-D8-V4-M3-D12 Multiprotocol module with PROFINET IO RT protocol node, M8 digital input module, M8 analogue output module, 37 pin (SUB-D) digital output module and M12 digital input module. Example shown: PX3-P-G-A4-3D8-2M12 Multiprotocol module with EtherCAT® protocol node, 3 M8 digital input modules and 2 M12 digital output modules; also includes DIN rail adaptors. Overall dimensions Overall dimensions and technical information are provided solely for informative purposes and may be modified...

 Open the catalog to page 7
MULTIPROTOCOL MODULE - SERIES PX-8

Solenoid valves manifold Cable complete with connector, male 37 poles, IP65 Coding: 2400.37.M.L.C CABLE LENGTH 03 = 3 meters 05 = 5 meters 10 = 10 meters CONNECTOR Overall dimensions and technical information are provided solely for informative purposes and may be modified witho

 Open the catalog to page 8
MULTIPROTOCOL MODULE - SERIES PX-9

Solenoid valves manifold Series PX - Module assembly instructions 1. Assemble the required modules starting with 3100.KT.03 right endplate kit. 2. Complete the assembly with the 3100.KT.00 left endplate kit. 3. To lock: rotate anticlockwise (in the direction of the LOCK print on the 4. If required, assemble the DIN rail adapter using an 3 mm allen key. case). To unlock: rotate clockwise (in the direction of the UNLOCK print on the case). The same procedure shall be used to add or remove any module. A. For integration with a manifold it is necessary to remove the 3100. KT.03 right endplate kit....

 Open the catalog to page 9
MULTIPROTOCOL MODULE - SERIES PX-10

Solenoid valves manifold Series PX - Serial systems CANopen® protocol node kit CANopen® node manages 64 inputs and outputs. Accessory modules can be connected in whatever order and configuration. Connection to CANopen® fieldbus is made via two M12, male and female, 5 pins, type A circular connectors, in parallel between them; connectors pinout is compliant to CiA Draft recommendation 303-1 (V. 1.3 : 30 December 2004). Transmission speed and address, as well as termination resistor activation are set via DIP-switches. CANopen® node is available in two versions with 32 or 48 outputs allocated to...

 Open the catalog to page 10
MULTIPROTOCOL MODULE - SERIES PX-11

Solenoid valves manifold Series PX - Serial systems PROFIBUS DP protocol node kit PROFIBUS DP node manages 64 inputs and outputs. Accessory modules can be connected in whatever order and configuration. Connection to PROFIBUS DP fieldbus is made via two M12, male and female, 5 pins, type B circular connectors, in parallel between them; connectors pinout is PROFIBUS Interconnection Technology specifications compliant (Version 1.1, August 2001). Address as well as termination resistor activation are set via DIP-switches. PROFIBUS DP node is available in two versions with 32 or 48 outputs allocated...

 Open the catalog to page 11
MULTIPROTOCOL MODULE - SERIES PX-12

Solenoid valves manifold Series PX - Serial systems EtherNet/IP protocol node kit EtherNet/IP node manages 128 inputs and outputs. Accessory modules can be connected in whatever order and configuration. Network connection is made via 2 M12 female, type D, 4 pins, circular connectors. Code K5730.128.48EI provides first 48 outputs, corresponding to least significant 6 bytes, are allocated to the solenoid valve positions, regardless how many they are and how many valves are installed on the manifold directly connected to the node. Remaining 80 outputs can be used to manage output modules; bytes...

 Open the catalog to page 12
MULTIPROTOCOL MODULE - SERIES PX-13

Solenoid valves manifold Series PX - Serial systems EtherCAT® protocol node kit EtherCAT® node manages 128 inputs and outputs. Accessory modules can be connected in whatever order and configuration. Network connection is made via 2 M12 female, type D, 4 pins, circular connectors. Code K5730.128.48EC provides first 48 outputs, corresponding to least significant 6 bytes, are allocated to the solenoid valve positions, regardless how many they are and how many valves are installed on the manifold directly connected to the node. Remaining 80 outputs can be used to manage output modules; bytes allocation...

 Open the catalog to page 13

All PNEUMAX catalogs and technical brochures

  1. PNEUMAX ACADEMY

    12  Pages

  2. SALES PROGRAM

    170  Pages

  3. LT LINE

    36  Pages

  4. ATEX OVERVIEW

    28  Pages

  5. VOLUME BOOSTER

    19  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.