cad

F5 Feedback unit
6Pages

{{requestButtons}}

Catalog excerpts

F5 Feedback unit - 1

PMV F5 Feedback unit Product Information

Open the catalog to page 1
F5 Feedback unit - 2

1. Jumper for field selection of 90, 60, 45 and 30 deg, operation for 4–20 mA position transmitter. 2. LEDs indicate 4 and 20 mA output. 3. Test outlet for 4–20 mA position transmitter. 4. Info printed on the PC board. 5. Field selectable direction of 4–20 mA of ouput signal, direct or reverse. 6. Easy to set cams with no fixed increments for true 100% resolution. F5 Feedback Unit F5/F5-EX • Mounts on P5/EP5 without additional mounting bracket. • Bright visible, flat or dome position indicator. • Easy to set stepless cams – 100% resolution. • Switches, mechanical or proximity, P+F Namur...

Open the catalog to page 2
F5 Feedback unit - 3

Technical data General Conduit entries Housing material Surface treatment Weight Mounting Fasteners Terminals Enclosure Temp* 2x1/2 NPT or 2xPG 13.5 (M20) Die cast aluminum ED painting 0,7 kg (lbs 1,5) Ex proof = 2,1 kg (lbs 4,6) Direct on P5/EP5 and VDI/VDE 3845 Stainless A2/A4 2,5 mm2 (AWG 14) Screw terminals IP66, NEMA 4 -40°C to 85°C (-40°F to 185°F) Switches, mechanical Type Mechanical SPDT V3 NAMUR sensors Load Current < 1mA > 3 mA Proximity switches Maximum operating time 0.5 milliseconds Contact resistance 0.2 Ohms Switch type SPDT hermetically sealed in one unit...

Open the catalog to page 3
F5 Feedback unit - 4

Modular F5 mounted on actuator for on/off applications F5 mounted on positioner P5 F5 mounted on positioner EP5 F5 Series Coding Model (for installation on P5/EP5 only) F5G F5 with PG 13.5 connections F5N F5 with NPT 1/2” connections Surface treatment U Epoxy, ED Switches MEC 2 x SPDT switches Feedback XXX None Model F5IS F5 Intrinsically safe Surface treatment U Epoxy, ED Switches MEC 2 x SPDT switches Feedback XXX None Frontcover, indicator PV9DA 90 deg, direct arrow indicator PV3RH 30 deg, reverse, Dome indicator Seals Z Nitrile, NBR Example...

Open the catalog to page 4
F5 Feedback unit - 6

FLOWSERVE p/n: FCD PMENBR0005-02 Hazardous Locations ATEX © II 1 G, EEx ia IIC T4 LCIE 95.D6 IIIX CSA, FM Class 1, Div 1, Group C, D T3C ATEX Explosion proof: ATEX © II 1 G, EEx d IIB+H2, T4-T6 LCIE 97.D6140 IIIX CSA, FM Div 1, Class 1,2 & 3 Group BCDEFG T4-T6, ATEX Ratt Grafiska AB Ordernr: 20971 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware...