Group: Plymovent Group
Catalog excerpts
SIF RANGE SIF-700/900/1200/1500/1800/1900/2000 LI/RI Extraction fan with straight blades to be used in central welding fume extraction systems or general filtration systems. It is mounted in a sound absorbing case with inspection cover either left (“LI” type) or right (“RI” type). The fan is equipped with flexible inlet and outlet adapters and placed on shock absorbers. In case it is combined with a central filter unit, the fan has to be connected to the outlet side of the filter unit. product data sheet APPLICATIONS The fans are intended to be used in the following configurations: – multiple arm systems – modular extraction hood systems – push-pull systems SPECIFICATIONS Physical properties Material: • fan • housing Options and accessories Mounting frame SIF Outdoor; fans suitable for outdoor installation (rainresistant) Outdoor kit consists of: • rain cover over sound absorbing case, including coupler for duct or silencer • ventilation grids provided with rain cover • seams of the absorbing case being fully sealed (except for the inspection cover) • steel • steel with aluminium profiles and corners Motor design Discharge position Design conditions Performance Speed of revolutions Noise level according to ISO 3746 (fan without sound absorbing case) refer to attached fan curves Noise reduction of sound absorbing case refer to table on page 3 Silencer (straight or elbow refer to table on page 3 90°) Scope of supply Extraction fan in sound absorbing case - Key - Strain relief Order information Number/package Shipping data Connection voltage Efficiency level Protection class Insulation class Electrical data Harmonized Tariff Code Ambient Design conditions Operating temperature: • min. • nom. • max. Storage Design conditions
Open the catalog to page 1FAN CURVES (QUICK REFERENCE TABLE) Detailed fan curves: refer to attachments Selection FAN LI/RI INSPECTION COVER LI = inspection cover left Remaining specifications: refer to table on next page. RI = inspection cover right
Open the catalog to page 2Table: remaining specifications SIF-900 Electrical data Mounting frame Refer to selection table below Silencer (straight or elbow 90°) Dimensions (ref. image below) and weights Nominal current Available options Order information Article number: • SIF/LI • SIF/RI • SIF/LI Outdoor • SIF/RI Outdoor Gross weight (incl. pallet) Shipping data Dimensions (ref. table above) SELECTION TABLE: FAN MOUNTING FRAMES Fan type SIF-700 Mounting frame*) Frame SIF-700/M MDB with horizontal bottom outlet The frame Altitude is based on MDB units with a vertical outlet. This concerns configurations consisting of...
Open the catalog to page 3STATIC PRESSURE / VOLUME CURVE (red line) Power curve (kW) Airflow (m³/h) Design conditions 15°C • Sound level (±3) at 1,5 m distance (free field) (red line) Power curve (HP) Airflow (CFM) Design conditions • Temperature • Sound level (±3) at 5 ft. distance (free fi
Open the catalog to page 4STATIC PRESSURE / VOLUME CURVE (red line) Power curve (kW) Airflow (m³/h) Design conditions 15°C • Sound level (±3) at 1,5 m distance (free field) (red line) Power curve (HP) Airflow (CFM) Design conditions • Temperature • Sound level (±3) at 5 ft. distance (free fi
Open the catalog to page 5STATIC PRESSURE / VOLUME CURVE (red line) Power curve (kW) Airflow (m³/h) Design conditions 15°C • Sound level (±3) at 1,5 m distance (free field) (red line) Power curve (HP) Airflow (CFM) Design conditions • Temperature • Sound level (±3) at 5 ft. distance (free fi
Open the catalog to page 6STATIC PRESSURE / VOLUME CURVE (red line) Power curve (kW) Airflow (m³/h) Design conditions 15°C • Sound level (±3) at 1,5 m distance (free field) (red line) Power curve (HP) Airflow (CFM) Design conditions • Temperature • Sound level (±3) at 5 ft. distance (free fi
Open the catalog to page 7STATIC PRESSURE / VOLUME CURVE (red line) Power curve (kW) Airflow (m³/h) Design conditions 15°C • Sound level (±3) at 1,5 m distance (free field) (red line) Power curve (HP) Airflow (CFM) Design conditions • Temperature • Sound level (±3) at 5 ft. distance (free fi
Open the catalog to page 8STATIC PRESSURE / VOLUME CURVE (red line) Power curve (kW) Airflow (m³/h) Design conditions 15°C • Sound level (±3) at 1,5 m distance (free field) (red line) Power curve (HP) Airflow (CFM) Design conditions • Temperature • Sound level (±3) at 5 ft. distance (free fi
Open the catalog to page 9STATIC PRESSURE / VOLUME CURVE
Open the catalog to page 10All PLYMOVENT catalogs and technical brochures
-
CR AB RETURN SYSTEM
2 Pages
-
Exhaust Hose Reels
6 Pages
-
FUMECADDIE™
2 Pages
-
EG exhaust extraction hose
2 Pages
-
SCS-Diluter PRO GO
3 Pages
-
SCS-DILUTER SYSTEM
4 Pages
-
SUS-5/230
1 Pages
-
UltraFlex-3
2 Pages
-
UltraFlex-4
2 Pages
-
Bayonet Quick Lock
1 Pages
-
Safety disconnect handle
2 Pages
-
FUA fan
4 Pages
-
FUA fan (60Hz)
9 Pages
-
TEV fan
4 Pages
-
TEV-fan (60hz)
7 Pages
-
Cutting & grinding helmet
2 Pages
-
SHIELD fire safety solutions
8 Pages
-
EF Exhaust extraction hose
2 Pages
-
EH exhaust extraction hose
2 Pages
-
ET exhaust extraction hose
2 Pages
-
ST exhaust hose
2 Pages
-
HT exhaust hose
2 Pages
-
MultiDust™ Bank
10 Pages
-
MDB-2F
2 Pages
-
ControlPro
4 Pages
-
MFS
2 Pages
-
MFD
2 Pages
-
DraftMax Eco
2 Pages
-
SFS
2 Pages
-
MNF
2 Pages
-
FAN-42
2 Pages
-
SFD
2 Pages
-
FAN-28
2 Pages
-
SCS Filter System
2 Pages
-
About us - Plymovent
9 Pages