Do you protect your firefighters? REMOVE DIESEL EXHAUST FROM YOUR FIRE STATION

Open the catalog to page 1
Remove diesel exhaust from your fire station - 2

EVER WONDER ABOUT THE VALUE OF CLEAN AIR? We do. Since 1975, we have made it our business to ensure clean air in fire stations. We provide high-quality products to protect firefighters and others from exposure to hazardous diesel exhaust. We offer a broad range of exhaust extraction systems, supported by complete engineering services. WHY PLYMOVENT ■ A genuine commitment to customer needs ■ Complete system solutions ■ Experience gained since 1975 ■ High-quality products ■ Global presence Contact us to find out what genuine commitment to customer requirements really me

Open the catalog to page 2
Remove diesel exhaust from your fire station - 3

DANGERS OF DIESEL EXHAUST Chemical Health effect* Benzene Benzo(a)pyrene Formaldehyde Dibenz(a,h)anthracene Benzofuran Carbon monoxide Nitric oxides DPM (Diesel Particulate Matter) Group 1, carcinogen to humans Group 1, carcinogen to humans Group 1, carcinogen to humans Group 2A, probably carcinogenic to humans Group 2B, possibly carcinogenic to humans Life threatening to humans Life threatening to humans Prolonged DE/DPM exposure can increase the risk of cardiovascular, cardiopulmonary and respiratory disease and lung cancer. *Source: OSHA.gov, IARC.fr REMOVE THE DANGERS OF DIESEL EXHAUST...

Open the catalog to page 3
Remove diesel exhaust from your fire station - 4

DIRECT SOURCE CAPTURE PLYMOVENT S O UR C E C A P T UR E S YS T E M S : T HE P NEU MATI C O R M AG N E T IC G R A BBE R ® SE T T I N G T H E INDUS TRY S TANDAR D Capture airborne particles at the source prior to their spreading in the local environment, is the most efficient method to achieve a safe and healthy working environment. It minimizes the amount of air that needs to be removed, thereby reducing the total investment in air handling equipment and also reducing the total energy consumption. A key component to our system is the sealed nozzle design called the Grabber®. The Plymovent...

Open the catalog to page 4
Remove diesel exhaust from your fire station - 5

Each system is designed to remove hazardous exhaust and provide for a healthier working environment. Based on years of experience working in the air treatment business, Plymovent has developed a totally reliable approach that we refer to as ”engineered solutions.” This approach ensures we offer an optimal solution for providing clean air in your working environment, taking such important elements into account, as value for money and efficient operation. The philosophy of Plymovent is to deliver quality systems that are safe, user friendly, regulation compliant and that will enhance the...

Open the catalog to page 5
Remove diesel exhaust from your fire station - 6

WHAT IS THE BEST SOLUTION FOR YOU? VERTICAL STACK RAIL SYSTEMS1 UNDER CARRIAGE RAIL SYSTEMS 2 FANS ■ We offer a wide range of fans covering most requirements in a variety of applications. ■ In-house manufactured ■ AMCA Certified RAILS / TRACKS ■ We can accommodate the varying demands of fire stations: facility layout, vehicle size, bay configuration and more. VSR CATCHER ■ Entry guide ■ Sealed entry gate ■ 35 cm (14 in) lateral movement to either side TROLLEY ■ Self supporting ■ Internal & external wheels ■ Adjustable impact cushions ■ Bi-directional release BALANCER ■ Adjustable ■ Strong...

Open the catalog to page 6
Remove diesel exhaust from your fire station - 7

UNDER CARRIAGE TRACK SYSTEMS 3 SAFETY DISCONNECT ■ Protects system ■ 360 degree swivel ■ Soft cover ■ No hose obstruction ■ Easy to operate and handle HOSE ASSEMBLIES ■ Multiple lengths ■ High temperature resistance CONTROLS ■ We offer fully automatic control systems which will operate with your exhaust system in the most efficient way ■ In-house manufactured

Open the catalog to page 7
Remove diesel exhaust from your fire station - 8

U N D E R C A R R I AG E TRACK SYSTEMS KEY ADVANTAGES SBT SYSTEM: ■ Models handle up to 9 meters (30 ft) deep back-in bays ■ Auto-disconnect at the exit door ■ Attach the Grabber® from the vertical position ■ Aluminum track: light-weight and strong ■ End stops with rubber shock absorbers take up kinetic energy from trolleys ■ Adjustable release points depending on the vehicles exit speed ■ Pre-fitted yellow/black extraction hose ■ Virtually 100% source capture through a unique automatic Grabber® nozzle; available in sizes to fit all emergency response vehicle tailpipe sizes ■ Automatic...

Open the catalog to page 8
Remove diesel exhaust from your fire station - 9

U N D E R C A R R I AG E RAIL SYSTEMS Plymovent provides two rail systems based on the type of trucks being supported: the Straight Rail System (STR) and the Vehicle Square Rail System (VSRX). Both systems are designed to connect to any motor vehicle tailpipe and capture virtually 100% of the exhaust emissions using the Magnetic or Pneumatic Grabber®. Both systems offer automatic fan activation and automatic release from the exiting vehicle. Additionally, both systems enable operators to easily hook up the hose as a vehicle enters the station. The STR system is ideal for drive through bays...

Open the catalog to page 9
Remove diesel exhaust from your fire station - 10

VERTICAL STACK RAIL SYSTEMS KEY ADVANTAGES VSR SYSTEM: ■ Floating suspension ■ Adjustable capture stack ■ Fits any vehicle stack ■ One piece aluminum rail ■ A fully automatic system ■ Expandable system to almost any length ■ Adapter cone designed for both empty and loaded vehicles ■ 350 mm (14 in) lateral movement to either side ■ Flexible duct connection ■ Sealing rubber lips ■ Automatic return to position after lateral movement ■ Safety cables; added security ■ Suitable for existing fire stations and new design-built stations The Vertical Stack Rail System (VSR) is the solution for...

Open the catalog to page 10
Remove diesel exhaust from your fire station - 11

IMPORTANT FACTS... ...ABOUT DIESEL EXHAUST ■ The World Health Organization (WHO) classified diesel engine exhaust as carcinogenic to humans, based on sufficient evidence that exposure is associated with an increased risk for lung cancer*. ■ The United States Environmental Protection Agency (EPA) has determined that the size of the average diesel exhaust particle sizes 0.2 microns. These particles are typically not visible to the human eye. ■ Diesel exhaust particles are often too small to be captured by onboard filters. Toxic gases are not captured by particulate filters, and only partially...

Open the catalog to page 11
Remove diesel exhaust from your fire station - 12

SALES OFFICE DISTRIBUTOR R EF EREN CES We have installed over 50,000 source capture systems across the world. Here are some examples: Australia Melbourne Fire Brigade Gatineau, Quebec Guelph, Ontario Winnipeg, Manitoba Pudong Airport LeedsBradfort Airport Salt Lake City, UT Plymovent cares about the air you breathe. We offer products, systems and services which ensure clean air at work, anywhere in the world. We respect the environment and we deliver high-quality products. Our expertise gained over many years and our genuine commitment to customer requirements enable us to provide precisely...

Open the catalog to page 12

All PLYMOVENT catalogs and technical brochures

  1. SCS-Diluter

    3 Pages

  2. SCS-Diluter

    4 Pages

  3. SUS-5/230

    1 Pages

  4. UltraFlex-3

    2 Pages

  5. UltraFlex-4

    2 Pages

  6. FUA fan

    4 Pages

  7. TEV fan

    4 Pages

  8. MDB-2F

    2 Pages

  9. ControlPro

    4 Pages

  10. MFS

    2 Pages

  11. MFD

    2 Pages

  12. DraftMax Eco

    2 Pages

  13. SFS

    2 Pages

  14. SIF

    10 Pages

  15. MNF

    2 Pages

  16. FAN-42

    2 Pages

  17. SFD

    2 Pages

  18. FAN-28

    2 Pages