Group: Plymovent Group
Catalog excerpts
FUA (60Hz) FUA-1800/2100/2700/3000/4700 The FUA is an extraction fan that is specially designed to remove exhaust gases, as well as welding and other fumes, dust and oil mist. The fan is intended and designed for mounting to extraction arms, filter units and vehicle exhaust extraction systems or can be used as a central fan. product data sheet The FUA fans are intended to be used for the following applications: • MIG-MAG/GMAW welding • TIG welding • FCAW welding • stick/MMAW welding • vehicle exhaust extraction systems Outlet transition from rectangular to round • OL-250/FUA-3000 Physical dimensions and properties Soft connection • aluminium • sheet metal Motor design backward inclined Design conditions Performance Max. starts/stops per hour Ambient conditions Operating temperature: • min. • nom. • max. Storage conditions Options and accessories Universal mounting bracket for freestanding, wall, or ceiling mounting • MB-FUA/S1 Shipping data Harmonized Tariff Code APPROVALS/CERTIFICATES FUA-1800/2100/2700: compliance with CE directives FUA-3000/4700: compliance with CE directives as part of an installation Directive 2011/65/EC (RoHS2) valid as of 8 June 2011 Plymovent certifies that the products shown herein are licensed to bear the AMCA Seal. The ratings shown comply with the requirements of the AMCA Certified Ratings Program. Certified motor Mounting bracket to mount the fan on a FlexMax extension crane, UK extractor crane or FEB boom arm • MB-FUA/C1
Open the catalog to page 1ARTICLE NUMBERS, WEIGHTS AND PACKING DIMENSIONS Fan type Connection voltage Article number Packing dimensions *) Gross weight = including packaging Remaining specifications: refer to next pages. Application restrictions Do not use the product for the following applications or in the following circumstances: aluminium laser cutting | extraction of aggressive fumes and gases (e.g. from acids, alkaline or soldering paste containing lithium) | extraction of hot gases (more than 176°F (80°C) continuously) | grinding aluminium and magnesium | flame spraying | extraction of cement, saw dust, wood...
Open the catalog to page 2POSSIBLE OUTLET POSITIONS FUA-1300/1800/ 2100/2700/3000
Open the catalog to page 3NOISE LEVEL Sub table A: Sound power levels (Lw) in dB Sound power is a measure of sound energy per time unit. For a sound source, unlike sound pressure, sound power is neither room dependent nor distance dependent. Sound power is a theoretical value that is not measurable. It is calculated and expressed in watts and as sound power level LW in decibels. The table below shows the sound power levels in dB calculated according to AMCA Standard 301. Octave band number & center frequency number (Hz) Airflow (CFM) Sub table B: Conversion of sound power level (Lw) to sound pressure level (Lp) A...
Open the catalog to page 7Energy efficiency (NEMA) Rated voltage Rated speed Rated current Rated torque Locked rotor torque Insulation class Temperature rise Locked rotor time Duty cycle Ambient temperature Preferred preset rotation direction CCW, seen from drive end side Approx. weight Sound pressure level (global) Foundation loads: • max. traction • max. compression Load: 100% • Power factor • Efficiency Load: 75% • Power factor • Efficiency Service factor Load: 50% • Power factor • Efficiency
Open the catalog to page 8Energy efficiency (NEMA) Rated voltage Rated speed Rated current Rated torque Locked rotor torque Insulation class Temperature rise Locked rotor time Service factor Duty cycle Ambient temperature Preferred preset rotation direction CCW, seen from drive end side Approx. weight Sound pressure level (global) Foundation loads: • max. traction • max. compression CCW, seen from drive end side Load: 100% • Power factor • Efficiency Load: 75% • Power factor • Efficiency Load: 50% • Power factor • Efficiency Page 9/9
Open the catalog to page 9All PLYMOVENT catalogs and technical brochures
-
CR AB RETURN SYSTEM
2 Pages
-
Exhaust Hose Reels
6 Pages
-
FUMECADDIE™
2 Pages
-
EG exhaust extraction hose
2 Pages
-
SCS-Diluter
3 Pages
-
SCS-Diluter
4 Pages
-
SUS-5/230
1 Pages
-
UltraFlex-3
2 Pages
-
UltraFlex-4
2 Pages
-
Bayonet Quick Lock
1 Pages
-
Safety disconnect handle
2 Pages
-
FUA fan
4 Pages
-
TEV fan
4 Pages
-
TEV-fan (60hz)
7 Pages
-
Cutting & grinding helmet
2 Pages
-
SHIELD fire safety solutions
8 Pages
-
EF Exhaust extraction hose
2 Pages
-
EH exhaust extraction hose
2 Pages
-
ET exhaust extraction hose
2 Pages
-
ST exhaust hose
2 Pages
-
HT exhaust hose
2 Pages
-
MultiDust™ Bank
10 Pages
-
MDB-2F
2 Pages
-
ControlPro
4 Pages
-
MFS
2 Pages
-
MFD
2 Pages
-
DraftMax Eco
2 Pages
-
SFS
2 Pages
-
SIF
10 Pages
-
MNF
2 Pages
-
FAN-42
2 Pages
-
SFD
2 Pages
-
FAN-28
2 Pages
-
SCS Filter System
2 Pages
-
About us - Plymovent
9 Pages