ABOUT COMPANY PLUTON is one of the largest manufacturers of electrotechnical equipment in Europe. The company holds key position in electrical industry and has been successfully working for over 25 years, implementing the strategy of intensive growth, development and continuous improvement of products and services quality. More than 70 kinds of various equipment produced by PLUTON are supplied to many countries around the world and are successfully operated in the fields of transport, energy and industry. PLUTON Group of companies has representative offices in 8 countries of the world and...

Open the catalog to page 2
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 3

Application of components with high switching capacity, high dynamic resistance to short-circuit currents and long mechanical life provides high reliability of equipment. Compliance with International Standards DC Switchgears manufactured by PLUTON were successfully type-tested for compliance with International Electrotechnical Commission (IEC) standards in such test centers as IPH Institut (Berlin, Germany) and IEL (Warsaw, Poland) including internal arc testing. DC Switchgears meet international standards EN 50123-1:2003 /I EC 61992-1:2014, EN 50123-6: 2003+A1:2014 / IEC 61992-6:2014. •...

Open the catalog to page 3
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 4

Switchgear components are mounted in separate compartments. High and low voltage compartments are separated from each other. The separation ensures operation reliability, equipment servicing and operational safety. Switchgears are manufactured both for uni- and bilateral maintenance. 1. Automatics and Control Compartment: • B&R (Austria) 4PPC70 panel controller with visualization function, • traction network monitoring and protection system SMTN-3, • mechanisms control modules, • contactor relay devices. 2. High Speed Circuit Breaker Compartment: • DC high speed circuit breaker, • operating...

Open the catalog to page 4
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 5

(1 High Speed Circuit Breaker (Secheron) • high switching capacity; • longtime mechanical durability; • minimum tripping time; • design providing minimum maintenance. @ Two-pole disconnector • crimp-type; • wiping contacts; • long time without maintenance; • silent efficient electric drive; • high electrodynamic resistance. 3 Line Tester (Short Circuits Tester SCT) line resistance measurement; high speed circuit breaker tripping interlock.

Open the catalog to page 5
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 6

4 Control, Monitoring and ^ Protection System • complete automation of cubicle and traction substation control; • cubicle and traction substation equipment condition monitoring with equipment selfdiagnostics function; • cubicle events logging at traction substation; • data transfer to the upper control level; • traction network protection with present day microprocessor system SMTN-3. © Cable Control System • resistance measurement range of external cable insulation 50 - 500 kOm; of internal cable insulation 200 - 2000 kOm; • operating line power supply; • 3 pairs of discrete failure...

Open the catalog to page 6
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 7

High speed circuit breakers (Switzerland) are applied in DC Switchgear. Circuit breakers of this type have high breaking capacity and dynamic stability to short circuit currents. Main advantages of high speed circuit breakers: • mechanical simplicity; • automatic adjustment of contact tightness; • long lifetime; • inspection after 250 protection trippings; insulation material wiping under arc; stepless regulation of trip setting; compliance of all insulation materials with strict International and European environmental standards requirements; minimum tripping time; no need for often...

Open the catalog to page 7
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 8

EST, EDT disconnectors manufactured by Elpro (Germany) are applied for electric power circuit switching. Disconnectors have a unique crimp-type contact system design with double gap and wiping contacts, geared by a small-sized electric drive. Easy rolling out of trolley with circuit breaker and EDT double-pole disconnector is achieved due to disconnector unique design. Each pole has two rows of lamellae. They are separated from each other in off-line state, and allow connected busbars entering lamellae gaps smoothly, without mechanical withstand strength. When activating disconnector...

Open the catalog to page 8
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 9

Switchgears are equipped with control, monitoring and protection system, which includes: • 4PPC70 panel controller with visualization function; • I/O modules series X20; • traction network monitoring and protection system SMTN-3. Main System Functions: • analysis of interlocks and implementation of traction substation control algorithms using microprocessor industrial controllers; • traction substation events logging for personnel actions and equipment operation analysing; • protection and recording of all network transient processes due to integrated traction network monitoring and...

Open the catalog to page 9
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 10

Types of electronic protections (ANSI code): • instantaneous overcurrent (50); • overcurrent protection (76); • current rate of rise protection; • current increment directional protection; • overvoltage protection (59); • undervoltage protection (27); • thermal protection (49); • breaker failure (BF). SMTN-3 generates and stores the following records: • events log; • failures log; • emergency oscillograph records. Records are stored on nonvolatile solid data storage medium that guarantees data storage in case of devices power supply interruption, and high reliability. SMTN-3 system provides...

Open the catalog to page 10
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 11

MAIN TECHNICAL PARAMETERS DC Switchgear Technical Parameters *- manufacturing of DC switchgear with parameters different from those stated above is made by special order

Open the catalog to page 11
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 12

Control Compartment High Speed Circuit Breaker Compartment Power Busbars and Cables Compartment Disconnectors Control Compartment

Open the catalog to page 12
DC SWITCHGEAR CITY ELECTRIC TRANSPORT ■ RAILWAYS ■ METRO - 13

SWITCHGEAR SINGLE-LINE DIAGRAMS Line Negative (line-type) Negative busbar " - " Negative busbar " - " Line Operating busbar " + " Earthing busbar Earthing busbar Earthing busbar Earthing busbar Rectifier 3 Earthing busbar Reserve current control module Reserve busbar Negative (modulartype) Stand-by Operating busbar " + " Negative Negative busbar " - " Voltage control module Earthing busbar Earthihg busbar Negative busbar " - " Negative busbar " - " Reserve busbar Line disconnector switchgear Negative switchgear Loop " - " Negative switchgear Line disconnector switchgear Earthing busbar...