MacMAT IV Flow Computer
4Pages

{{requestButtons}}

Catalog excerpts

MacMAT IV Flow Computer - 1

Flowcomputer MacMAT IV is a key element of safe and precise measuring systems for flows of large volume of natural gas. It guarantees safety of work, data security and interference protection, as a result of more than 25 years of experience in volume correctors and flowcomputers development. MacMAT IV is equipped with intrinsically-safe, explosion-proof measuring inputs as well as binary inputs allowing to connect devices from Ex-Zone. has IP65 protection class, and provides high level of electromagnetic compatibility (EMC). The device also has a redundant power supply system. Measuring circuits provide long-term high stability and they combine functionality of digital communication interfaces to cooperate with transducers and flowmeters. MacMAT IV is designed for direct co-operation with gas meters: ultrasonic, mass, turbine, rotary, and external chromatographs and calorimeters. Built-in 100 Mbps Ethernet interface and quick serial RS485/RS422 port working with baud rates up to 460 kbps allow to an easy integration with IT systems. Distinguishing features of MacMAT IV • • • 64-bites processor with pipelining allows to on-line work in 250ms cycle with real calculation all of computation algorithms Device has intrinsically-safe measuring circuits, which can be connected direct in explosion-proof areas High efficiency redundant communication channels with external SCADA, DSC, PLC systems, ultrasonic gas meters, gas chromatographs: Ethernet port, four galvanically insulated serial ports RS485/422, local communication in infrared is proper with IEC 62056-21, USB host, intrinsically-safe galvanically insulated four HART modems Multilevel access for administrators and users via built-in WEB server, supporting advanced configuration and mapping measurements variables between cooperating devices PLUM Ltd. Wspolna 19, Ignatki,16-001 Kleosin, Poland gas@plummac.com www.plumma

Open the catalog to page 1
MacMAT IV Flow Computer - 2

Gas Technical specification Measuring inputs accuracy Computation algorithms Analog inputs Four analog inputs 4÷20 mA Independent HART modems on current loop 4-20mA, working HART digital inputs in point-point mode, multidrop and in diagnostic measuring channel mode One LF input, two HF inputs NAMUR standard with detecting Pulse inputs dis-/connection wires, configurable switch thresholds by PN-EN 60947-5-6:2002 • Ethernet port RJ45 100Mb • 3x separated RS485 channels, baud rate up to 460kbps • 1 RS422/485 channel , baud rate up to 460 kbps • Infrared interface, IEC 62056-21, baud rate up to...

Open the catalog to page 2
MacMAT IV Flow Computer - 3

1.Pressure transducer 2.Temperature transducer (Exi product version) 1.Pressure transducer 2.Temperature transducer (ExD product version) Gas mass meter Coriolis Gas volume conversion device Gas volume conversion device Gas volume conversion device PLUM Ltd. Wspolna 19, Ignatki,16-001 Kleosin, Poland gas@plummac.com www.plummac.com

Open the catalog to page 3
MacMAT IV Flow Computer - 4

Gas Enclosure conditions / MacMAT IV 1 Measuring inputs 2 Transmission circuits 3 Controlling circuits 4 Ethernet port 5 USB 6 Optical Interface MacMAT IV device is equipped with 6 independent, high efficiency communication channels. These channels can work in MASTER or SLAVE mode, that makes possible integration of MacMAT IV with devices and measuring stations systems (chromatographs, dew point converters, controllers) and billings systems SCADA. modem/router 3G Extension modules IK-301 Operator A Modbus RTU (1) Billing system GazColektor MASTER mode SLAVE mode PLUM Ltd. Wspolna 19,...

Open the catalog to page 4