MacBAT 5 electronic conversion GSM 2G/3G/LTE modem Gas volume and energy device with intergrated MacBAT 5 is a gas volume corrector that enables PTZ, PT or T conversion. The device is designed to measure volume, energy and flow of gas. Primarily battery powered with the possibility to connect external power supply. The device converts the volume of gas counted by the gas meter (turbine, rotary, ultrasonic) into the base conditions. Gas compressibility factor is calculated with the use of algorithms SGERG-88, MGERG-88, AGA8-92DC, AGA8-G1, AGA8-G2, AGA NX-19 mod or constant value of relative compression factor. MacBAT 5 is an intrinsically safe device ready to be installed in explosive hazardous zone 0. Main features of the MacBAT 5 • Industrial housing cooperates with various types of gas meter like turbine, rotary, ultrasonic directly by LF, HF, Namur, Encoder, Wiegand • 4 independent serial transmission ports (2xRS485 + OPTICAL INTERFACE 62056-21+ NFC IEC 14443) • Built-in GSM/GPRS modem (option) • Backlight graphic display • 5 configurable binary Ex inputs • 2 configurable binary NAMUR Ex inputs (operating on battery mode) • Binary and frequency outputs • Internal or external pressure transducers available • More than 10 years of archive registered data storage (with monthly sampling interval) PLUM Sp. z o.o. Wspolna 19, Ignatki, 16-001 Kleosin, Poland gas@plummac.com www.plummac.com
Open the catalog to page 1Technical specification Dimensions Weight Housing material Relative humidity Ambient temperature range Housing protection class Keyboard Display Ex classification Internal EVC supply Internal GSM supply External supply Transmission ports Transmission protocols Environment conditions class (Mechanical/Electromagnetic) Base conditions 206x194x76 mm 1,3 kg Polycarbonate enclosure (version 1) or metal (version 2) max 95% at temp. 70°C -25°C up to 70°C IP 66 (for outdoor installation) 6 pushbuttons (version 1) or 18 pushbuttons (version 2) LCD - graphic 4” with backlight © II 1 G Ex ia I IB T4...
Open the catalog to page 2Gas Communication 1. Direct transfer of data to system – Data readout through internal GSM/GPRS modem with the use of internal batteries Ex SCADA or Billing system 2. Remote data readout – connection through communication interfaces INT-S3, RTU controller independently Ex 2xDO: Converted volume pulse retransmission (counters Vb ) conversion alarm RS 485 3. Process of measurement using MacBAT 5 and turbine gas meter GSM/GPRS/SMS Pressure monitoring after reduction ENCODER HF Pressure-reducing valve Temperature measurement Pressure measurement 4. Process of measurement using MacBAT 5 (with...
Open the catalog to page 3Gas MacBAT 5 accessories INT-S3 | Transmission interface Performs as an external power supply to the intrinsically safe measurement device (located in stationary telemetric systems supplied from 11-30V DC or a battery that is located in explosive zone 0, 1, or 2). Additionally, data is transmittable to a readout device (i.e. computer) via RS485 port. EM-1 | Extension module Extends the functionality of MacBAT 5 by adding two additional current outputs operating in 4-20mA current loop and four binary relay type outputs. Can operate as a standalone device as it has its own parameters that can...
Open the catalog to page 4All PLUM Sp z.o.o catalogs and technical brochures
-
MacR6 Z0
71 Pages
-
MacREJ 5
4 Pages
-
MacMAT IV Flow Computer
4 Pages
-
MacR6N
4 Pages
-
MacR6
4 Pages