Overview: The DG02 Rotor-Type Flow Indicator is designed for visual verification of liquid and gas flow. It features a robust stainless steel construction, suitable for a variety of media, with a maximum pressure of 16 bar and a maximum temperature of 200°C. The device is equipped with a glass dome for clear rotor visibility and is compatible with pipe sizes ranging from G ¼ to G 1 ½.
Specifications:
  • Material: Stainless steel
  • Max Pressure: 16 bar
  • Max Temperature: 200°C
  • Flow Velocity: Max 3 m/s for liquids
  • Installation: Suitable for various positions, limited for top to bottom flow
Applications: The DG02 is used to monitor the flow of low to medium viscosity liquids and gases in pipe systems.
Models and Flow Rates:
  • G 1/4: Max flow 30 l/min, Start-up 0.7 l/min
  • G 3/8: Max flow 40 l/min, Start-up 0.8 l/min
  • G 1/2: Max flow 55 l/min, Start-up 1 l/min
  • G 3/4: Max flow 90 l/min, Start-up 1.2 l/min
  • G 1: Max flow 140 l/min, Start-up 1.5 l/min
  • G 1 1/4: Max flow 180 l/min, Start-up 4 l/min
  • G 1 1/2: Max flow 200 l/min, Start-up 4 l/min
Dimensions:
  • G 1/4: L 76 mm, H 53 mm, X 12 mm, Weight 0.7 kg
  • G 3/8: L 76 mm, H 53 mm, X 16 mm, Weight 0.65 kg
  • G 1/2: L 76 mm, H 53 mm, X 14 mm, Weight 0.65 kg
  • G 3/4: L 89 mm, H 66 mm, X 18 mm, Weight 1.25 kg
  • G 1: L 89 mm, H 66 mm, X 18 mm, Weight 1.2 kg
  • G 1 1/4: L 115 mm, H 73 mm, X 25 mm, Weight 2.7 kg
  • G 1 1/2: L 116 mm, H 95 mm, X 26 mm, Weight 2.5 kg
Order Code: DG02.E.10.0 with options for material and connection types.
Technical Data:
  • Housing: Stainless steel 1.4408, ASME 316
  • Sight Glass: Borosilicate glass
  • Rotor: PPS
  • O-Ring: FKM
  • Gasket: Klingersil C-4400
Contact Information: PKP Prozessmesstechnik GmbH, Borsigstr. 24, D-65205 Wiesbaden, Phone: +49 (0) 6122-7055-0, Email: [email protected], Website: www.pkp.de
See more

Catalog excerpts

Rotor-Type Flow Indicator-1

Flow Measurement and Monitoring DG02 Rotor-Type Flow Indicator • for liquids and gases • robust stainless steel design • max. pressure 16 bar, max. temperature 200 °C • good rotor visibility through glass dome • for pipe sizes G ¼ to G 1 ½ Description: The DG02 mechanical flow indicator is used for visual verification of liquids and gases. Typical applications: DG02 mechanical flow indicators are used to monitor the flow of liquids of low to medium viscosity and gases in pipe systems. The rotational speed of the rotor is proportional to the liquid flow rate. The domed sight glass allows the rotor to be easily seen at any time. These devices are made of high-quality materials, allowing them to be used with a great variety of media. PKP Prozessmesstechnik GmbH Borsigstr. 24 • D-65205 Wiesbaden

 Open the catalog to page 1
Rotor-Type Flow Indicator-2

Order Code: stainless steel Order number: Flow rates: Rotor-type flow indicator Qmax recom. [l/min] water Water [l/min] Rotor start-up Connection: 08 = G ¼ female thread 10 = G 3/8 female thread 15 = G ½ female thread 20 = G ¾ female thread 25 = G 1 female thread 32 = G 1 ¼ female thread 40 = G 1 ½ female thread 0 = without 1 = please specify in plain text Max. pressure: Max. MediumTemperature: Installation position: Technical Data: 16 bar (20 °C) 200 °C for the flow direction from top to bottom suitable to only a limited extend, otherwise any Materials: DG02.E: Housing: Housing cover: Sight...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.