Introduction
The ST series safety sensors employ RFID technology to detect actuators, offering high-level coded actuators with numerous coding combinations to prevent tampering. These sensors are ideal for applications with large tolerances and evolving mechanical properties.
Specifications
The sensors achieve maximum safety levels of PL e and SIL 3 with a single device, featuring redundant electronics for series connection of up to 32 sensors while maintaining safety standards. They comply with directives and standards such as EN ISO 14119 and EN 62061.
Features
- Contactless actuation using RFID technology.
- Protection degrees of IP67 and IP69K for harsh environments.
- Programmable sensors with durable laser engraving.
- Four LEDs for immediate sensor status diagnosis.
- External Device Monitoring (EDM) function.
- Resistant to dirt, suitable for agricultural and food industries.
Technical Data
- Rated operating voltage: 24 Vdc or 12-24 Vdc.
- Maximum current per output: 0.25 A.
- Ambient temperature range: -25°C to +70°C.
- Compliant with IEC 60068 standards for vibration and shock resistance.
Actuation and Connection Options
Actuators come with different coding levels and actuation distances (12 mm and 20 mm). Connection options include PVC cables and M12 connectors in various lengths.
Compliance and Approvals
The sensors comply with Machinery Directive 2006/42/EC, EMC Directive 2014/30/EC, and other international standards, with UL, TÜV SÜD, and EAC approvals for industrial reliability and safety.
Conclusion
The ST series safety sensors offer a robust solution for industrial safety applications, providing flexibility, high safety standards, and adaptability to various environmental conditions.
Power Supply Electrical Data
The rated operating voltage ranges from 24 Vdc to 12-24 Vdc, with operating current from 40 mA to 0.7 A. The rated insulation voltage is 32 Vdc, and the impulse withstand voltage is 1.5 kV. An external protection fuse of 1 A type F is recommended, and the device is in overvoltage category III.
Housing
The housing is made of glass fibre reinforced technopolymer, self-extinguishing, with versions available with integrated cables or M12 stainless steel connectors, offering IP67 and IP69K protection.
Electrical Data of Inputs
The rated operating voltage for inputs is 24 Vdc or 12-24 Vdc, with a current consumption of 5 mA.
Safety Sensors and Actuators
RFID technology in ST series sensors supports two actuator types: Type •0T with the same code and Type •1T with different codes. Sensors are compatible with various safety modules and can be connected in series for simplified wiring.
Internal Block Diagram
The document details internal sensor functions, including power supply monitoring, input status monitoring, actuator position monitoring, and safety output activation, with LED indicators for each function.
Operating States and Recommendations
The document outlines sensor operating states, including power on, run, and error states, with recommended actions for each. It also describes the limit and safe activation zones for the actuator.
Connection and Installation
Details on various connection types, including internal connections with cables and connectors, emphasizing maintaining maximum safety levels during installation.
Operating Distances and Dimensional Drawings
Operating distances for different actuators are provided, along with dimensional drawings for various sensor configurations.
See more

Catalog excerpts

ST series safety sensors with RFID technology-1

ST series safety sensors with RFID technology

 Open the catalog to page 1
ST series safety sensors with RFID technology-2

ST series safety sensors with RFID technology Introduction In combination with the corresponding safety modules, the sensors of the ST series are suitable for the monitoring of protective devices on machines without inertia and allow the system in which they are used to reach a safety category up to SIL 3 acc. to EN 62061 as well as up to PL e and Category 4 acc. to EN ISO 13849‑1. These sensors use RFID (Radio Frequency IDentification) technology and provide high protection against possible manipulation thanks to the uniqueness of the codes transmitted by the actuator. Because they have no mechanical...

 Open the catalog to page 2
ST series safety sensors with RFID technology-3

Laser engraving Pizzato Elettrica supplies a pro‑ grammable version of the ST series sensors. With a simple and brief ope‑ ration, the sensor can be program‑ . med to recognise the code of a new 0.. 011 actuator. 010 0 By activating a special input, the sensor is switched to a safe state, during which it waits for a new code to be accepted. As the actuator approaches, the ST sensor performs a number of checks on the code being received, whereby the code must adhere to certain parameters of RFID technology. If the checks are successful, the sensor uses LEDs to signal the suc‑ cessful completion...

 Open the catalog to page 3
ST series safety sensors with RFID technology-4

ST series safety sensors with RFID technology Selection diagram SENSOR actuation distance 12 mm front fixing actuation distance 12 mm two-sided fastening actuation distance 20 mm front fixing OUTPUT TYPE ST DD•••MK integrated M12 connector at the right ST DL•••MK integrated M12 connector at the left cable, length: 0.1 m, with M12 connector at the right cable, length: 0.1 m, with M12 connector at the left product option access

 Open the catalog to page 4
ST series safety sensors with RFID technology-5

Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. Code structure for sensor with actuator ST DD420N2-D1T Output direction, connections D output at the right L output at the left Actuator low level coded actuator D0T the sensor recognises any type D1T high level coded actuator the switch recognises one single type D1T actuator low level coded actuator the sensor recognises any type E0T actuator the switch recognises one single type E1T actuator low level coded actuator the sensor recognises any type L0T actuator...

 Open the catalog to page 5
ST series safety sensors with RFID technology-6

ST series safety sensors with RFID technology Technical data Housing Housing made of glass fibre reinforced technopolymer, self-extinguishing. Versions with integrated cable 6 x 0.5 mm2 or 8 x 0.34 mm2, length 2 m, other lengths 0.5 m … 10 m on request Versions with M12 stainless steel connector Versions with 0.1 m cable length and integrated M12 connector, other lengths 0.1 … 3 m on request Protection degree: (Protect the cables from direct high-pressure and hightemperature jets) General data For safety applications up to: Interlock, no contact, coded: Level of coding acc. to EN ISO 14119: Main...

 Open the catalog to page 6
ST series safety sensors with RFID technology-7

Selection table for sensors with high level coded actuators cable, length: 0.1 m, with M12 connector at the right To order a product with E*T actuator replace D with E in the codes shown above. Example: ST DD310M0.1-D*T ST DD310M0.1-E*T Selection table for sensors Selection table for actuators Level of coding acc. to ISO 14119 The use of RFID technology in ST series sensors makes them suitable for several applications. Pizzato Elettrica offers two different versions of actuators, in order to best suit customers' specific needs. Type »0T actuators are all encoded with the same code. This implies...

 Open the catalog to page 7
ST series safety sensors with RFID technology-8

Complete safety system The use of complete and tested solutions guarantees the electrical compatibility between the sensors of the ST series and the safety modules from Pizzato Elettrica, as well as high reliability. The sensors have been tested with the modules listed in the adjacent table. The adjacent diagram illustrates five logical, linked sub-functions of the sensor. Function f0 is a basic function and includes the monitoring of the power supply as well as internal, cyclical tests. Function fl monitors the status of the inputs, whereas function f2 monitors the position of the actuator in...

 Open the catalog to page 8
ST series safety sensors with RFID technology-9

Limit activation zone and safe activation zone (ST D^4«m) When aligning the sensor with the actuator, the status LEDs use various colours to indicate whether the actuator is in the limit activation zone or in the safe activation zone. The following figures use the ST DD420MK-D1T sensor as an example. Oldl rffjt /// ACT IN OUT PWR Operating voltage is applied to the sensor, (LED PWR on, green), the inputs are enabled (LED IN on, green), the outputs are deactivated (LED OUT off). The actuator is outside of the actuation zone (LED ACT off). If the actuator is moved inside the safe activation zone...

 Open the catalog to page 9
ST series safety sensors with RFID technology-10

Connections with CS AR-08**** safety modules Connections with CS AR-05**** / CS AR-06**** safety modules Series connection To simplify series connections of the devices, various M12 connectors are available that allow complete wiring. This solution significantly reduces installation times while at the same time maintaining the maximum safety levels PL e and SIL 3. For further information see general catalogue security 2017-2018. ST series safety sensors

 Open the catalog to page 10
ST series safety sensors with RFID technology-11

Operating distances SM D*T/SM L*T actuators 25 20 15 10 5 0 Operating distances SM E*T actuator 30 25 20 15 10 5 0 15 20 -20 -15 -10 -5 10 15 20 Legend: Rated operating distance Sn (mm) Rated release distance sm (mm) Note: The trend of activation areas is indicative, possible application on ferromagnetic surfaces can reduce the activation distances. Dimensional drawings ST DD***N* sensor with cable at the right ST DD***MK sensor with M12 connector at the right {0 ST DL***N* sensor with cable at the left The 2D and 3D files are available at www.pizzato.com ST series safety sensors

 Open the catalog to page 11
ST series safety sensors with RFID technology-12

General Catalogue Detection General Catalogue Safety General Catalogue LIFT Pizzato Elettrica s.r.l. Via Torino, 1 - 36063 Marostica (VI) Italy Phone +39.0424.470.930 - Fax +39.0424.470.955 E-mail: [email protected] - Web site: www.pizzato.com © 2017 Copyright Pizzato Elettrica

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.