Piller UB-V Series HIGH PERFORMANCE UPS FOR DATA CENTRES Nothing protects quite like Piller piller.com

Open the catalog to page 1
ub-v-series - 3

UB-V series high performance UPS for all large scale data centres Introducing Piller’s new high-performance UB-V ELECTRICALLY COUPLED UPS series for the conditioned power protection needs of cloud hyperscale, wholesale colocation and large enterprise deployments. The Piller UNIBLOCK™ UB-V is a flexible solution providing up to 3.24MW of UPS in a single module to give higher reliability compared with large scale static deployments and better availability through Single UB-V UPS modules deliver up to 3.24MW for power at scale significantly extended preventative maintenance service intervals...

Open the catalog to page 3
ub-v-series - 4

Providing power stability at scale Electrically Coupled UPS UB-V electrically coupled UPS works well with renewable and sustainable energy sources for bi-directional power flow feeding energy back to the grid ELECTRICALLY COUPLED UB-V SERIES UPS BENEFITS n he UB-V series unit’s power ratings range from 1100kVA 1.0MW to T 3600kVA 3.24MW in both battery and kinetic energy storage versions, making them ideal for large scale deployment. connects the energy store with the UPS unit using only an electrical connection. Power semiconductors are used to control the energy flow for both discharging...

Open the catalog to page 4
ub-v-series - 5

Cloud, Colo and Enterprise For wholesale colocation companies who build At every level colocation managers and their cloud redundant power which is both stable and flexible. and operate data centres at scale to service high peers must be highly responsive to customer needs Piller’s UB-V electrically coupled UPS power end business critical workloads for multiple com- for flexible power and varying power densities. infrastructure is specifically designed to meet all mercial and enterprise customers, reliability and They must ensure maximum operational efficiency these supplier and customer...

Open the catalog to page 5
ub-v-series - 6

The UB-V’s compact design can generate space in a 50MW data centre to house up to 250 additional IT racks Space saved

Open the catalog to page 6
ub-v-series - 7

Capital efficiency of UB-V series UPS Hyperscale companies are driven by the quest As enterprises increasingly shift workloads to the Piller UB-V series has been designed with reduced for ever greater efficiency in every area. Build-out cloud and as cloud-based digitally native firms infrastructure capital costs firmly in mind. The more growth rates of next generation data centres make expand, fierce competition among cloud providers its power rating rises, the more favourable the capital it vital to optimise capital investment from day one further increases the need for cost control and...

Open the catalog to page 7
ub-v-series - 8

Operational efficiency multiple operating and predictive maintenance parameters and can send system data directly to an operation centre. In efficiency terms, the UB-V UPS with a battery power source compares favourably with static saved in operational costs with, for example, a UPS. UB-V, provides on-line efficiency of up to A 48MW data centre equipped with UB-V UPS can save up to $7.5 million in electricity costs over ten years At multi-MW scale, this can represent vast sums 48MW data centre saving up to $7.5 million in 98% at 100% load and 97% at 50% load, against electricity costs over...

Open the catalog to page 8
ub-v-series - 9

UB-V benefits over static UPS Because the UB-V UPS series has been designed without power capacitors or electric fans and has no internal paralleling of power strings, the mean time between failure of a single unit rises by a factor of 5 (hundreds of thousands of hours to millions) when compared with the failure rates of a typical static UPS. Static UPS use for large scale data centres means paralleling many low power modules. With the UB-V series UPS operates for years with minimal on-site maintenance visits UB-V UPS series the smallest unit delivers 1.0MW and a single unit can provide...

Open the catalog to page 9
ub-v-series - 10

Piller business and technology pedigree Piller was founded in Hamburg, Germany in 1909 by engineer Anton Piller. Employing around 1000 people worldwide, Piller Global coverage with over 300 service personnel across 24 countries is headquartered in Osterode, near Hanover, Germany, with subsidiaries across Europe, America, Asia and Australia. Piller occupies a unique position, being the only company to produce both types of electrically coupled UPS technologies and with kinetic energy storage or battery options. The company also manufactures aircraft ground power units, 50/60Hz frequency...

Open the catalog to page 10
ub-v-series - 11

AI, IoT and Edge will generate hundreds of Zettabytes of data annually – thousands of MW of stable power in cloud, commercial and enterprise data centres is needed for the data volume explosion

Open the catalog to page 11
ub-v-series - 12

HEADQUARTERS Piller Group GmbH Abgunst 24 37520 Osterode Germany Tel: +49 5522 311 0 E: info@piller.com ELECTRICALLY COUPLED UPS CONTAINERISED UPS STABILISERS STATIC TRANSFER SWITCHES KINETIC ENERGY STORAGE AIRCRAFT GROUND POWER SYSTEMS FREQUENCY CONVERTERS NAVAL POWER SUPPLIES SYSTEM INTEGRATION Subsidiaries: AUSTRALIA | CHINA | FRANCE | GERMANY | INDIA | ITALY | SINGAPORE | SPAIN | UK | USA Sales & Service: AUSTRIA | BRAZIL | CANADA | CZECH REPUBLIC | FINLAND | HONG KONG | MALAYSIA | MEXICO | NETHERLANDS | PORTUGAL | RUSSIA | SOUTH KOREA | SWEDEN | TAIWAN Agents & Distributors: ALGERIA |...

Open the catalog to page 12

All PILLER catalogs and technical brochures

  1. piller-naval

    8 Pages

  2. UBR series

    12 Pages

Archived catalogs

  1. Static UPS

    8 Pages

  2. Dynamic UPS

    12 Pages