Catalog excerpts
ECONOMY LINE DUAL-RANGE PRESSURE TRANSMITTER DESCRIPTION APZ 2410 economy line pressure transmitters feature up to two pressure ranges selectable by the user via ZCON 100 configurator tool, allowing customers to have reduced inventory of spare instruments. Based on a monolythic ceramic measuring cell, highly resistive to abrasive and aggressive* media, APZ 2410 is a good fit for the applications where hydraulic shocks (water hammer) are not present. APZ 2410 feature improved overpressure capability as compared to model APZ 2412, which offers improved accuracy. Number of ranges: up to 2, user-selectable via ZCON 100** Pressure type: gauge Accuracy: ±1% FS of the highest chosen range Output: 4...20 mA / 2-wire Sensor: ceramic thick film Pressure port: G1/2“; G1/4“; 1/2“ NPT; 1/4“ NPT; M20x1.5 etc. Media temperatures: -25...+135 °C Improved overpressure capability comparing to model APZ 2412 APPLICATIONS Pneumatics Hydraulics*** Transportation (*) Please consult the manufacturer for particular media compatibility (**) ZCON 100 configurator is sold separately and provides ZERO TRIM and RANGE SWITCHING features (***) Applications with absence of excessive hydraulic shocks Appearance, mounting kit contents and/or specifications are subject to change without prior notice. We are constantly working on further improvement of our products. Delivery is subject to standard terms of delivery. © 2020 Piezus Page 1. Version: 11.0 Date: 20.05.2020
Open the catalog to page 1TECHNICAL SPECIFICATIONS MEASURING RANGES Pressure range, bar* Gauge 0...1.0 0...1.6 0...2.5 0...4.0 0…6.0 0...10 * Transmitter can be calibrated on two adjacent (user-selectable via ZCON 100 configurator) pressure ranges. Accuracy, % of span* ≤ ±1 Temperature effect, (% of span / 10 °C) ≤ ±0.3 Compensated range -25…+85 °C Power supply effect ≤ ±0.05% of span / 10 V Load resistance effect ≤ ±0.05% of span / kOhm Long term stability ≤ ±0.3% of span / year Response time (10...90%) ≤ 1 ms * Accuracy includes non-linearity, hysteresis and non-repeatability. OPERATING CONDITIONS Medium...
Open the catalog to page 2ELECTRICAL CONNECTIONS, DIMENSIONS (mm) DIN 43650A PRESSURE PORTS, DIMENSIONS (mm) M20x1.5; G1/2” EN 837 Page. 3. Version: 11.0 Date: 20.05.2020
Open the catalog to page 3MEASUREMENT TYPE Gauge UNIT OF MEASUREMENT PRESSURE PORT DIN 43650A Other (specify when ordering) 4…20 mA / 2-wire Other (specify when ordering) Page. 4. Ordering code. Version: 11.0 Date: 20.05.2020
Open the catalog to page 4ORDERING CODE (CONTINUED) APZ 2410 FKM (-25...+135 °C) Other (specify when ordering) Standard Zero calibration (requires a ZCON 100 configurator) Dual range, zero calibration (requires ZCON 100 configurator) Other (specify when ordering) * Ratings for dual range version can be chosen from the scope of single range version ratings. Max range comes first, next range comes second. E.g., the range code for 6 and 4 bar is 6000-4000. Example: APZ 2410-G-B-6000-4000-E-10-A-201-F-02 ZCON 100 Zero trim and range selection device ANZ 200 Plug-in display for transmitters with 4-20 mA output Page. 5....
Open the catalog to page 5All PIEZUS catalogs and technical brochures
-
ANZ 200
4 Pages
-
ANZ 3420 G
5 Pages
-
ALZ 3824
5 Pages
-
ALZ 3822
5 Pages
-
ALZ 3920
4 Pages
-
ALZ 3742
5 Pages
-
ALZ 3740
5 Pages
-
ALZ 3821
5 Pages
-
ALZ 3820
5 Pages
-
ALZ 3721
5 Pages
-
ALZ 3720
5 Pages
-
ASZ 3410 p
7 Pages
-
ASZ 3420 p
7 Pages
-
ASZ 3410 r
8 Pages
-
ASZ 3420 r
8 Pages
-
APZ 2410 a
5 Pages
-
APZ 2422
5 Pages
-
APZ 2412
5 Pages
-
APZ 3020
7 Pages
-
APZ 3230
8 Pages
-
APZ 3240
6 Pages
-
APZ 3410
8 Pages
-
APZ 3420 s
8 Pages
-
APZ 3420 m
8 Pages
-
APZ 3421
8 Pages
-
APZ 3420 x
6 Pages
-
APZ 2030
5 Pages
-
APZ 3420
9 Pages
-
AMZ 5450
7 Pages
-
ANZ 3410 G
5 Pages
-
APZ 2422 а
5 Pages
-
ALZ 3925
4 Pages
-
AMZ 5050
7 Pages