Series UAC
6Pages

{{requestButtons}}

Catalog excerpts

Series UAC - 1

Measurements = inches NOTE: The torque for mounting screws much be 3 - 5 In-Lbs. Meets EN/IEC 61000-3-2 Requirements Universal Input Voltage: 85 to 265 VAC Power Factor Corrected, 0.99 (50 -100% Full Load) Space Saving Design: One module replaces two Special Output Voltages Available Regulated Output Voltage Made in the uSa, Fully Encapsulated Typical Features/Electrical Characteristics AC Line Input Voltage: 85 to 265 VAC 47-440 Hz Output Power: 100 to 200 watts, see chart Output Voltage Ripple: 75-200 mV, See chart Start Up Current Typical: 120 VAC Input: 20-40 AMPS 240 VAC Input: 15-20 AMPS Operating Temperature: 0 to 85° C, case temperature. See application notes for proper thermal considerations. Isolation: From Input to DC Output: 4242 VDC From Input or DC output to Case: 2121 VDC From AC Input to Auxiliary 380 VDC Output: Non-Isolated Capacitor Requirement: External at Auxiliary 380 VDC Pins: 220f 450 Volt Electrostatic * MUST BE INSTALLED Short Circuit Protection: Continuous Operating Frequency: 100KHz

Open the catalog to page 1
Series UAC - 2

(ALUM. ELEC) MUST BE INSTALLED j Weight: 245 grams 7.6 oz typical

Open the catalog to page 2
Series UAC - 3

All dimensions are in inches ()=mm Approx. weight = 145 grams NOTE: Additional Heatsink options, consult factory Approx. Weight = 145 grams THERMAL INTERFACE PART TI Alloy Aluminum Substrate Thermal Conductivity, (BTU-in/hr ft² °F) ----1530 Coefficient of Thermal Expansion (25-100°C, 10-6 in./in. °F ---13.1 Hardness, Brinnell B ----23 Endurance Limit, psi. ----5

Open the catalog to page 3
Series UAC - 5

A UAC24S module has an efficiency of 80%. What is the maximum ambient temperature if 100 Watts of power is needed. A) In free air From Table 1: T.«. = 5.1 Using Relation (2) AT = 5.1 (100) [o^jg - l]=127.5°C Ta = 85-127.5 = -42.5°C B) In free air with heatsink (CV). EXAMPLE 2: What would be the maximum output power for a UAC24S module at an ambient temperature of 50°C with an efficiency of 80%. A) If the module is used in free air. From Table 1: T.~ = 5.1 Using Relation (2) 85 -50 - 5-1 P~ [ok - ’] P~=5TO=27-5Wat,S B) If the module is used in an area with forced air at 200 LFM with no...

Open the catalog to page 5
Series UAC - 6

EXAMPLE 3: At a maximum ambient temperature of 5CTC and an efficiency of 80%, how could a UAC24S module be used if 200 Watts of output power is required. Using Relation (2), we first find the maximum thermal resistance from case to air. AT. T-(200) [gig-l] 85 - 50 = Tic* {5.0} T-™ - 0.7 A} If no heatsink is used. From Table 1, more than 1,000 LFM of airflow is required. B) if a (CV) heatsink is used. 700 LFM of airflow is required. C) If a (CH) heatsink is used. 400 LFM of airflow is required. For immediate engineering assistance or to place an order: Can Toll Free: 800-431-1064 PICO...

Open the catalog to page 6

All Pico Electronics catalogs and technical brochures

  1. HPHA2

    4 Pages

  2. 78000 series

    4 Pages

  3. SERIES SA

    8 Pages

  4. Series LPB

    3 Pages

  5. Series DC2B

    6 Pages

  6. QP SERIES

    8 Pages

  7. 50AC

    4 Pages

  8. HPHA2

    5 Pages

  9. AC1

    8 Pages

  10. UACHV

    7 Pages

  11. HiQP SERIES

    9 Pages