The SAR series modules are isolated DC-DC converters with 0% to 100% output voltage programmable by internal reference or external voltage. These modules have an internal reference voltage and shutdown. Protections include input over/undervoltage, over temperature and over programming. Through hole and surface mount packages are available. Every single output has a center tap for a dual output configuration. Due to a resonant design, it exhibits a very low load effect. 0-100% programmable output feature Up to 3W output power 2:1 wide input voltage range with 0.5% line regulation Protected against input over/undervoltage, over temperature and over programming Internal reference voltage feature Shutdown feature Single or dual output configuration Contact Pico for part number of available options: • Expanded operating temp: -55°C to +85°C Stabilization Bake Temperature Cycle Burn-In • Available RoHS Compliant module • Special Input Voltage, Output Voltage, Isolation Voltage or Output Power BLANK = THROUGH HOLE SM = SURFACE MOUNT 2025 REV 2 www.PicoElectronics.com | Series SAR & SAR-SM 443
Open the catalog to page 1MODEL LIST THROUGH HOLE SURFACE MOUNT Note 1: Tested at nominal input voltage and full output load. Note 2: Tested at nominal input voltage. SPECIFICATIONS (Nominal VIN, Full Load, TA = +25°C, 1 hour warm up unless otherwise specified) www.PicoElectronics.com | Series SAR & SAR-SM
Open the catalog to page 2Series SAR & SAR-SM High Voltage DC-DC DATA CURVES (Nominal VIN, TA = +25°C, 1 hour warm up unless otherwise specified) DATA CURVES P/N 28SA100 / 28SA100SM @ Nominal VIN Output Voltage (VDC) TYPICAL CONNECTION CIRCUIT OUTPUT VOLTAGE PROGRAMMING RESISTOR - 5SAR & 12SAR MODELS ONLY VOUT = Programmed Output Voltage VNOM = Nominal Output Voltage RPROG = Resistance in kΩ EXTERNAL VOLTAGE - ALL MODELS INTERNAL VOLTAGE REFERENCE - ALL MODELS Note 2: Output Voltage Programming can program the output voltage 0 to 100% Vout using 0 to 3V range. Open connection defaults to 100% Vout. Note 3: Programming...
Open the catalog to page 4Series SAR & SAR-SM High Voltage DC-DC TYPICAL CONNECTION CIRCUIT SHUTDOWN ISOLATED Note 1: Shutdown will shut down the unit when the pin is pulled below 0.4V. The unit will restart once the pin reaches operating input voltage. SINGLE OUTPUT OPERATION Note 4: Nominal output voltage is measured between +OUT and -OUT. For single output, COM should be disconnected. DUAL OUTPUT OPERATION Note 5: Nominal output voltage is measured between +OUT and -OUT. For dual outputs, COM will be half of the voltage between +OUT and -OUT. Both loads must be balanced. 2025 REV 2 www.PicoElectronics.com | Series...
Open the catalog to page 5BOTTOM VIEW www.PicoElectronics.com | Series SAR & SAR-SM
Open the catalog to page 6Series SAR & SAR-SM High Voltage DC-DC RECOMMENDED LAND PATTERN DIMENSIONS .140 [3.556] .070 [1.778] ELEVATION VIEW PLAN VIEW SEALED UNSEALED TUBE PACKAGE TUBE PLUG TUBE PLUG POWER SUPPLY Pico warrants each product manufactured by us and sold by us or an authorized representative, to be free from defects in material and workmanship. If properly used, it will perform within its applicable specifications for a period of one year after original shipment. Pico’s obligation under this guarantee is limited to repairing or replacing our product to the original purchaser. This warranty is in lieu of...
Open the catalog to page 77 Pages
12 Pages
9 Pages
12 Pages
13 Pages
9 Pages
13 Pages
9 Pages
14 Pages
13 Pages
13 Pages
14 Pages
6 Pages
8 Pages
8 Pages
8 Pages
8 Pages
6 Pages
11 Pages
13 Pages
5 Pages
8 Pages
10 Pages
12 Pages
11 Pages
10 Pages
10 Pages
10 Pages
7 Pages
6 Pages
9 Pages
13 Pages
7 Pages
7 Pages
8 Pages
9 Pages
10 Pages
7 Pages
8 Pages
9 Pages
8 Pages
13 Pages
9 Pages
9 Pages
6 Pages
8 Pages
8 Pages
14 Pages
8 Pages
10 Pages
6 Pages
7 Pages
8 Pages
8 Pages
7 Pages
9 Pages
10 Pages
12 Pages
7 Pages
13 Pages
9 Pages
10 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
8 Pages