100W Isolated Regulated High Power DC-DC Converter Electronics, Inc. PRODUCT OVERVIEW The P series are isolated DC-DC converters with a wide selection of input voltage ranges from 18V to 380V in a low profile full brick size - 4.6” x 2.4” x 0.5” (<100V output) or 4.6” x 2.5” x 0.5” (>125V output). These modules have trim capability and shutdown features. Protections include input overvoltage, output short-circuit, output overvoltage and over temperature. The unique case has integrated side heat sink for better thermal dissipation but is capable of conduction cooling through the baseplate or additional top mounted heat sink. • 18V to 380V input range models • Input/output isolation • Integrated side heat sink • Parallel operation option • Single and dual isolated outputs • Up to +85°C baseplate operating temperature • Trim capability • Remote shutdown feature • Fixed operating frequency • No external components required Contact Pico for part number of available options: • Expanded operating temp: -55°C to +85°C Stabilization Bake Temperature Cycle Burn-In • Special Input Voltage, Output Voltage, Isolation Voltage or Output Power • Parallel Operation
Open the catalog to page 1High Power DC-DC PICO MODEL LIST - PA (18-36V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%). Note...
Open the catalog to page 2High Power DC-DC PICO MODEL LIST - PB (36-72V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%). Note...
Open the catalog to page 3High Power DC-DC PICO MODEL LIST - PC (100-180V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%). Note...
Open the catalog to page 4High Power DC-DC PICO MODEL LIST - PD (200-380V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%). Note...
Open the catalog to page 5High Power DC-DC PICO LSPECIFICATIONS (Nominal V|N, Full Load, TA = +25°C, 1 hour warm up unless otherwise specified) Note 6: The parallel option allows units to operate the outputs in parallel to share load, increase total power or allow for N+1 redundancy.
Open the catalog to page 6High Power DC-DC PICO SPECIFICATIONS (Nominal V|N, Full Load, TA = +25°C, 1 hour warm up unless otherwise specified)DESIGNED TO MEET Test Models with Max. Output Power = 75W, Output Voltage <100V & Efficiency at full load = 78%Models with Max. Output Power = 100W,Output Voltage <100V & Efficiency at full load = 86% 2026 REV 2
Open the catalog to page 7High Power DC-DC PICO DERATING GRAPHS (Nominal V|N, Full Load, Efficiency @ Full Load) Models with Max. Output Power = 125W, Output Voltage <125V & Efficiency at full load = 85% Models with Max. Output Power = 150W, Output Voltage <125V & Efficiency at full load = 85% TYPICAL CONNECTION CIRCUIT TRIM DOWN —\AAA-R +INTRIMTRIM UP-IN O' R TRIM DOWN +IN TRIM DOWN TRIM -IN A VOUT Note: Each individual unit will vary slightly. It is recommended to use a IMOhm multi-turn trimmer potentiometer to determine resistance value and achieve desired adjustment. Use minimum 1/2W power rating resistor. Keep the...
Open the catalog to page 8Series P High Power DC-DC TYPICAL CONNECTION CIRCUIT NOISE REDUCTION C1 (7) TRIM DOWN TRIM Note 7: C1 filter capacitors may reduce noise further. Please contact Pico for more details. SHUTDOWN NON-ISOLATED
Open the catalog to page 9High Power DC-DC PICO MECHANICAL DRAWINGS DUAL OUTPUTS b. RECOMMENDED TORQUE FOR MOUNTING SCREWS: 6-9 INCH-LBS
Open the catalog to page 10High Power DC-DC PICO MECHANICAL DRAWINGS BOTTOM VIEW b. RECOMMENDED TORQUE FOR MOUNTING SCREWS: 6-9 INCH-LBS
Open the catalog to page 11Series P High Power DC-DC MECHANICAL DRAWINGS THERMAL INTERFACE BOTTOM VIEW Material Alloy Aluminum Substrate Thermal Conductivity Coefficient of Thermal Expansion, (25-100°C) Brinell Hardness Endurance Limit Standard Thickness HEAT SINKS TOP VIEW 2.100 [53.340] Weight: 145 grams typical 2026 REV 2
Open the catalog to page 12High Power DC-DC PICO MECHANICAL DRAWINGS HEAT SINK ASSEMBLY .502 [12.751]
Open the catalog to page 13Series P High Power DC-DC TUBE PACKAGING UNSEALED TUBE PACKAGE TUBE PLUG TUBE PLUG POWER SUPPLY Pico warrants each product manufactured by us and sold by us or an authorized representative, to be free from defects in material and workmanship. If properly used, it will perform within its applicable specifications for a period of one year after original shipment. Pico’s obligation under this guarantee is limited to repairing or replacing our product to the original purchaser. This warranty is in lieu of all other warranties, express or implied and constitutes fulfillment of our obligations to the...
Open the catalog to page 147 Pages
12 Pages
9 Pages
12 Pages
13 Pages
9 Pages
11 Pages
9 Pages
14 Pages
13 Pages
13 Pages
6 Pages
8 Pages
8 Pages
8 Pages
8 Pages
6 Pages
11 Pages
13 Pages
5 Pages
8 Pages
10 Pages
12 Pages
11 Pages
10 Pages
10 Pages
10 Pages
7 Pages
6 Pages
9 Pages
13 Pages
7 Pages
7 Pages
8 Pages
9 Pages
10 Pages
7 Pages
8 Pages
9 Pages
8 Pages
7 Pages
9 Pages
9 Pages
6 Pages
8 Pages
8 Pages
14 Pages
8 Pages
10 Pages
6 Pages
7 Pages
8 Pages
8 Pages
7 Pages
9 Pages
10 Pages
12 Pages
7 Pages
13 Pages
9 Pages
10 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
8 Pages
13 Pages