The F/M series are isolated DC-DC converters with a wide selection of input voltage ranges from 18V to 380V in a low profile full brick size - 4.6" x 2.5" x 0.5". These modules have trim capability and shutdown features. Protections include input overvoltage, output short-circuit, output overvoltage and over temperature. The unique case has integrated side heat sink for better thermal dissipation but is capable of conduction cooling through the baseplate or additional top mounted heat sink. • 18V to 380V input range models • Input/output isolation • Parallel operation option • Single and dual isolated outputs • Trim capability • Remote shutdown feature • Fixed operating frequency • No external components required Contact Pico for part number of available options: • Expanded operating temperature: -55°C to +85°C Stabilization Bake Temperature Cycle Burn-In • Special Input Voltage, Output Voltage, Isolation Voltage or Output Power • Parallel Operation
Open the catalog to page 1High Power DC-DC PICO MODEL LIST - FA/MA (18-36V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%). Note...
Open the catalog to page 2High Power DC-DC PICO MODEL LIST - FB/MB (36-72V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%). Note...
Open the catalog to page 3High Power DC-DC PICO MODEL LIST - FC/MC (100-180V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%)....
Open the catalog to page 4High Power DC-DC PICO MODEL LIST - FD/MD (200-380V INPUT RANGE) Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load (+%) and 50% to 100% load (-%)....
Open the catalog to page 5High Power DC-DC PICO SPECIFICATIONS (Nominal V|N, Full Load, TA = +25°C, 1 hour warm up unless otherwise specified) Note 6: The parallel option allows units to operate the outputs in parallel to share load, increase total power or allow for N+1 redundancy.
Open the catalog to page 6High Power DC-DC PICO SPECIFICATIONS (Nominal V|N, Full Load, TA = +25°C, 1 hour warm up unless otherwise specified) DERATING GRAPHS (Nominal VIN, Full Load, Efficiency @ Full Load) Ambient Temperature (° C) Ambient Temperature (° C)
Open the catalog to page 7High Power DC-DC PICO DERATING GRAPHS Models with Max. Output Power = 100W Models with Max. Output Power = 100W & Efficiency at full load = 85% & Efficiency at full load = 86% Models with Max. Output Power = 100W & Efficiency at full load = 87% Models with Max. Output Power = 100W & Efficiency at full load = 88% Ambient Temperature (° C)Ambient Temperature (° C)TYPICAL CONNECTION CIRCUIT TRIM TRIM DOWNO' —\AAA-R +INTRIMTRIM UP-IN O' R TRIM DOWN +IN TRIM DOWN TRIM -IN A VOUT Note: Each individual unit will vary slightly. It is recommended to use a 1MQ multi-turn trimmer potentiometer to determine...
Open the catalog to page 8High Power DC-DC TYPICAL CONNECTION CIRCUIT NOISE REDUCTION C1 (7) TRIM DOWN TRIM Note 7: C1 filter capacitors may reduce noise further. Please contact Pico for more details. SHUTDOWN NON-ISOLATED
Open the catalog to page 9High Power DC-DC MECHANICAL DRAWINGS ≤48V SINGLE OUTPUT MODELS .500 [12.700] TRIM DOWN SHUT DOWN TRIM DOWN BOTTOM VIEW ≥100V SINGLE OUTPUT MODELS .500 [12.700] SHUT DOWN BOTTOM VIEW NOTES a. ALL DIMENSIONS ARE IN INCHES, [ ] = MM b. RECOMMENDED TORQUE FOR MOUNTING SCREWS: 6-9 INCH-LBS 2026 REV 2 www.PicoElectronics.com | Se
Open the catalog to page 10High Power DC-DC MECHANICAL DRAWINGS DUAL OUTPUT MODELS .500 [12.700] TRIM DOWN SHUT DOWN BOTTOM VIEW NOTESv a. ALL DIMENSIONS ARE IN INCHES, [ ] = MM b. RECOMMENDED TORQUE FOR MOUNTING SCREWS: 6-9 INCH-LBS
Open the catalog to page 11High Power DC-DC MECHANICAL DRAWINGS THERMAL INTERFACE BOTTOM VIEW Material Alloy Aluminum Substrate Thermal Conductivity Coefficient of Thermal Expansion, (25-100°C) Brinell Hardness Endurance Limit Standard Thickness HEAT SINKS TOP VIEW 2.100 [53.340] Weight: 145 grams typical 2026 REV 2
Open the catalog to page 12High Power DC-DC PICO MECHANICAL DRAWINGS HEAT SINK ASSEMBLY
Open the catalog to page 13High Power DC-DC TUBE PACKAGING UNSEALED TUBE PACKAGE TUBE PLUG TUBE PLUG POWER SUPPLY Pico warrants each product manufactured by us and sold by us or an authorized representative, to be free from defects in material and workmanship. If properly used, it will perform within its applicable specifications for a period of one year after original shipment. Pico’s obligation under this guarantee is limited to repairing or replacing our product to the original purchaser. This warranty is in lieu of all other warranties, express or implied and constitutes fulfillment of our obligations to the purchaser....
Open the catalog to page 147 Pages
12 Pages
9 Pages
12 Pages
13 Pages
9 Pages
11 Pages
9 Pages
13 Pages
13 Pages
14 Pages
6 Pages
8 Pages
8 Pages
8 Pages
8 Pages
6 Pages
11 Pages
13 Pages
5 Pages
8 Pages
10 Pages
12 Pages
11 Pages
10 Pages
10 Pages
10 Pages
7 Pages
6 Pages
9 Pages
13 Pages
7 Pages
7 Pages
8 Pages
9 Pages
10 Pages
7 Pages
8 Pages
9 Pages
8 Pages
7 Pages
9 Pages
9 Pages
6 Pages
8 Pages
8 Pages
14 Pages
8 Pages
10 Pages
6 Pages
7 Pages
8 Pages
8 Pages
7 Pages
9 Pages
10 Pages
12 Pages
7 Pages
13 Pages
9 Pages
10 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
8 Pages
13 Pages