Series F/M
1 /14Pages

Series F/M

Series F/M
1 /14Pages

Catalog excerpts

Series F/M-1

PRODUCT OVERVIEW The F/M series are isolated DC-DC converters with a wide selection of input voltage ranges from 18V to 380V in a low profile full brick size - 4.6" x 2.5" x 0.5". These modules have trim capability and shutdown features. Protections include input overvoltage, output short-circuit, output overvoltage and over temperature. The unique case has integrated side heat sink for better thermal dissipation but is capable of conduction cooling through the baseplate or additional top mounted heat sink. FEATURES • 18V to 380V input range models • Input/output isolation • Parallel operation option • Single and dual isolated outputs • Trim capability • Remote shutdown feature • Fixed operating frequency • No external components required Contact Pico for part number of available options: • Expanded operating temperature: -55°C to +85°C Stabilization Bake Temperature Cycle Burn-In • Special Input Voltage, Output Voltage, Isolation Voltage or Output Power • Parallel Operation

 Open the catalog to page 1
Series F/M-2

Series F/M High Power DC-DCMODEL LIST - FA/MA (18-36V INPUT RANGE)SINGLE OUTPUT Pico Part Number Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load...

 Open the catalog to page 2
Series F/M-3

Series F/M High Power DC-DCMODEL LIST - FB/MB (36-72V INPUT RANGE)SINGLE OUTPUT Pico Part Number Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load...

 Open the catalog to page 3
Series F/M-4

Series F/M High Power DC-DCMODEL LIST - FC/MC (100-180V INPUT RANGE)SINGLE OUTPUT Pico Part Number Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load...

 Open the catalog to page 4
Series F/M-5

Series F/M High Power DC-DCMODEL LIST - FD/MD (200-380V INPUT RANGE)SINGLE OUTPUT Pico Part Number Note 1: Maintain minimum 10% of rated load to prevent a voltage surge. Note 2: Tested at nominal input voltage and full output load. Note 3: Line regulation is specified at full output load, nominal to minimum input voltage (-%) and nominal to maximum input voltage (+%). Note 4: For <100V output models, load regulation is specified at nominal input voltage, 50% to 10% load (+%) and 50% to 100% load (-%). For >125V output models, load regulation is specified at nominal input voltage, 50% to 20% load...

 Open the catalog to page 5
Series F/M-6

Series F/M High Power DC-DC GENERAL Potting Vacuum Impregnated Epoxy Aluminum baseplate and Glass Reinforced Polymer Note 6: The parallel option allows units to operate the outputs in parallel to share load, increase total power or allow for N+1 redundancy.

 Open the catalog to page 6
Series F/M-7

DERATING GRAPHS (Nominal VIN, Full Load, Efficiency @ Full Load)Models with Max. Output Power = 75W & Efficiency at full load = 78%Models with Max. Output Power = 100W & Efficiency at full load = 84%756045 1-Q)

 Open the catalog to page 7
Series F/M-8

Models with Max. Output Power = 100W & Efficiency at full load = 87%Models with Max. Output Power = 100W & Efficiency at full load = 88%1008060 1-0) TYPICAL CONNECTION CIRCUITTRIM TRIM UP TRIM DOWN TRIM DOWN. TRIM TRIM UP SHUTDOWN -IN TRIM DOWN TRIM DOWN, TRIM TRIM UP SHUTDOWN -IN kO typ. Note: Each individual unit will vary slightly. It is recommended to use a 1MO multi-turn trimmer potentiometer to determine resistance value and achieve desired adjustment. Use minimum 1/2W power rating resistor. Keep the trim resistor leads as short as possible to eliminate the stray inductance which will effect...

 Open the catalog to page 8
Series F/M-9

Series F/M High Power DC-DC TYPICAL CONNECTION CIRCUIT NOISE REDUCTION TRIM DOWN TRIM Note 7: C1 filter capacitors may reduce noise further. Please contact Pico for more details.

 Open the catalog to page 9
Series F/M-10

b. RECOMMENDED TORQUE FOR MOUNTING SCREWS: 6-9 INCH-LBS

 Open the catalog to page 10
Series F/M-11

b. RECOMMENDED TORQUE FOR MOUNTING SCREWS: 6-9 INCH-LBS

 Open the catalog to page 11
Series F/M-12

Weight: 145 grams typical

 Open the catalog to page 12
Series F/M-14

Series F/M High Power DC-DC TUBE PACKAGING TUBE PACKAGE TUBE PLUG TUBE PLUG POWER SUPPLY Pico warrants each product manufactured by us and sold by us or an authorized representative, to be free from defects in material and workmanship. If properly used, it will perform within its applicable specifications for a period of one year after original shipment. Pico’s obligation under this guarantee is limited to repairing or replacing our product to the original purchaser. This warranty is in lieu of all other warranties, express or implied and constitutes fulfillment of our obligations to the purchaser....

 Open the catalog to page 14

All Pico Electronics catalogs and technical brochures

  1. 78000 Series

    7  Pages

  2. Series AC

    9  Pages

  3. Series PHA

    12  Pages

  4. Series LP

    13  Pages

  5. Series QP

    13  Pages

  6. Series HP

    13  Pages

  7. Series LF/LM

    13  Pages

  8. Series P

    14  Pages

  9. Series 5AC

    6  Pages

  10. Series 10AC

    8  Pages

  11. Series 30AC

    8  Pages

  12. Series 50AC

    8  Pages

  13. Series HVP

    6  Pages

  14. Series AVR

    5  Pages

  15. Series HIP

    10  Pages

  16. Series A & SM

    12  Pages

  17. Series B & SB

    10  Pages

  18. Series C & SC

    10  Pages

  19. Series E & SE

    10  Pages

  20. Series HILR

    6  Pages

  21. Series IR & SIR

    13  Pages

  22. Series JR

    7  Pages

  23. Series KR

    7  Pages

  24. Series LR

    8  Pages

  25. Series M & MV

    10  Pages

  26. Series MR

    7  Pages

  27. Series NR

    8  Pages

  28. Series PLR

    8  Pages

  29. Series QP

    13  Pages

  30. Series UAC

    9  Pages

  31. Series UWD

    8  Pages

  32. Series XP

    10  Pages

  33. Series 37000

    6  Pages

  34. Series 38000

    7  Pages

  35. Series 68500

    8  Pages

  36. Series 69000

    8  Pages

  37. Series 72000

    7  Pages

  38. Series 73000

    9  Pages

  39. Series HCM

    7  Pages

  40. Series Y

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.