The AV & SMV series are unregulated DC-DC converters in a low profile 0.5" package footprint with up to 10,000V positive or negative output models. 0.5" x 0.5" footprint packages are available up to 5kV; 1.0" x 0.5" are available up to 10kV. They can operate over the temperature range of -25°C to +70°C without derating, a heat sink or active cooling. • Output voltage is directly proportional to input voltage • Through hole mounting • Transformer Isolated modules • Positive or negative output voltage up to 10kV • Single output models • No heat sink or derating required Contact Pico for part number of available options: • Expanded operating temp: -55°C to +85°C Stabilization Bake Temperature Cycle Burn-In • Special Input Voltage, Output Voltage, Isolation Voltage or Output Power BLANK = ISOLATED POSITIVE OR NEGATIVE -P = NON-ISOLATED POSITVE OUTPUT -N = NON-ISOLATED NEGATIVE OUTPUT P = NON-ISOLATED POSITVE OUTPUT N = NON-ISOLATED NEGATIVE OUTPUT
Open the catalog to page 1Note 1: Tested at nominal input voltage and full output load. Note 2: Maintain minimum 10% of rated load on the output to prevent a voltage surge. Note 3: For <5000V output models, a 470pF, 6kV high quality capacitor is required across the output. For >6000V output models, optional capacitors up to 470pF may be placed across the output for further ripple reduction. Note 4: For isolated models, input ground and output ground is not connected internally. Input ground and output ground cannot be connected externally.
Open the catalog to page 3Note 1: Tested at nominal input voltage and full output load. Note 2: Maintain minimum 10% of rated load on the output to prevent a voltage surge. Note 3: For <5000V output models, a 470pF, 6kV high quality capacitor is required across the output. For >6000V output models, optional capacitors up to 470pF may be placed across the output for further ripple reduction. Note 5: For non-isolated positive models, output COM terminal must be connected to input positive or input negative externally. Output will be positive voltage and non-isolated from input. Module is internally transformer isolated.
Open the catalog to page 5Note 1: Tested at nominal input voltage and full output load. Note 2: Maintain minimum 10% of rated load on the output to prevent a voltage surge. Note 3: For <5000V output models, a 470pF, 6kV high quality capacitor is required across the output. For >6000V output models, optional capacitors up to 470pF may be placed across the output for further ripple reduction. Note 6: For non-isolated negative models, output COM terminal must be connected to input positive or input negative externally. Output will be negative voltage and non-isolated from input. Module is internally transformer isolated.
Open the catalog to page 7Series AV (1500-10kV) High Voltage DC-DC SPECIFICATIONS (Nominal VIN, Full Load, TA = +25°C, 1 hour warm up unless otherwise specified) OPTIONS AVAILABLE – CONTACT PICO FOR PART NUMBER Parameter Referenced Standard Stabilization Bake Referenced Method 1008 Non-operating maximum storage temperature for 24 hours Temperature Cycle Referenced Method 1010 Non-operating at temperature extremes, 15 mins/temp, 10 cycles Referenced Method 1015 Max operating temperature for 160 hours OPTIONS AVAILABLE Expanded Ambient Operating Temperature DATA CURVES (Nominal VIN, TA = +25°C, 1 hour warm up unless otherwise...
Open the catalog to page 9■o+IN +OUT<^ <>-IN -OUT<h NON-ISOLATED POSITIVE MODELS ■<>+IN +OUT^ -IN COM<h Note 3: For <5000V output models, a 470pF, 6kV high quality capacitor is required across the output. For >6000V output models, optional capacitors up to 470pF may be placed across the output for further ripple reduction. Note 4: For isolated models, input ground and output ground is not connected internally. Input ground and output ground cannot be connected externally. Note 5: For non-isolated positive models, output COM terminal must be connected to input positive or input negative externally. Output will be positive...
Open the catalog to page 10Series AV (1500-10kV) High Voltage DC-DC MECHANICAL DRAWINGS ≤5000V OUTPUT MODELS NON-ISOLATED POSITIVE OUTPUT NON-ISOLATED NEGATIVE OUTPUT BOTTOM VIEW BOTTOM VIEW NOTES a. ALL DIMENSIONS ARE IN INCHES, [ ] = MM b. COMMON OUTPUT MUST BE CONNECTED TO +IN OR -IN INPUT 2025 REV 0 BOTTOM VIEW
Open the catalog to page 11Series AV (1500-10kV) High Voltage DC-DC MECHANICAL DRAWINGS ≥6000V OUTPUT MODELS ISOLATED POSITIVE OUTPUT 1.000 [25.400] BOTTOM VIEW ISOLATED NEGATIVE OUTPUT 1.000 [25.400] BOTTOM VIEW NOTES a. ALL DIMENSIONS ARE IN INCHES, [ ] = MM b. COMMON OUTPUT MUST BE CONNECTED TO +IN OR -IN INPUT 2025 REV 0
Open the catalog to page 12Series AV (1500-10kV) High Voltage DC-DC TUBE PACKAGING .600 [15.240] TUBE PLUG TUBE PLUG POWER SUPPLY Pico warrants each product manufactured by us and sold by us or an authorized representative, to be free from defects in material and workmanship. If properly used, it will perform within its applicable specifications for a period of one year after original shipment. Pico’s obligation under this guarantee is limited to repairing or replacing our product to the original purchaser. This warranty is in lieu of all other warranties, express or implied and constitutes fulfillment of our obligations...
Open the catalog to page 137 Pages
12 Pages
9 Pages
12 Pages
13 Pages
9 Pages
13 Pages
9 Pages
14 Pages
13 Pages
13 Pages
14 Pages
6 Pages
8 Pages
8 Pages
8 Pages
8 Pages
6 Pages
11 Pages
5 Pages
8 Pages
10 Pages
12 Pages
11 Pages
10 Pages
10 Pages
10 Pages
7 Pages
6 Pages
9 Pages
13 Pages
7 Pages
7 Pages
8 Pages
9 Pages
10 Pages
7 Pages
8 Pages
9 Pages
8 Pages
13 Pages
7 Pages
9 Pages
9 Pages
6 Pages
8 Pages
8 Pages
14 Pages
8 Pages
10 Pages
6 Pages
7 Pages
8 Pages
8 Pages
7 Pages
9 Pages
10 Pages
12 Pages
7 Pages
13 Pages
9 Pages
10 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
8 Pages