TR.Nc + IY.Nc Manual - 1

Easy plug-in mounting Quick and safe installation Junction box integrated No variants only one basic unit Enhanced temperature range -40 … +70 °C Degree of protection IP66 Analog outputs switchable between mA and V Outputs calibrated and scaled Integrated display Onsite parameterization LED status indication Low power input <3 W Cable length from the transducer to the sensor up to 100 m Highly resistant against corrosion by use of high-tech polymer and stainless steel TR.Nc + IY.Nc Manual Assembly and installation instructions for safe use of transducer TR.Nc with mA/V output and sensors IY.Nc for Temperature, Humidity, Dew point, Differential pressure, Volume flow measurement

Open the catalog to page 1
TR.Nc + IY.Nc Manual - 2

TR.Nc / IY.Nc normal condition / Industrieanwendung Content 1. General __________________________________________________________________________________________________ 3 2. Product description _________________________________________________________________________________________ 3 3. Technical Data _____________________________________________________________________________________________ 4 4. Dimension ________________________________________________________________________________________________ 6 5. Assembly / Installation...

Open the catalog to page 2
TR.Nc + IY.Nc Manual - 3

TR.Nc / IY.Nc normal condition / Industrieanwendung The manual is included in the delivery and serves to ensure proper handling and optimum functioning of the device. The manufacturer offers no guarantee for this publication and is not liable for any improper handling of the products described. For this reason, the manual has to be read before operation. In addition, all personnel who are involved in the transport, setup, operation, maintenance and repair are to be familiar with this manual. This manual may not, without the prior written consent of the manufacturer be used for competition...

Open the catalog to page 3
TR.Nc + IY.Nc Manual - 4

TR.Nc / IY.Nc normal condition / Industrieanwendung 3. Technical Data TR.Nc SUPPLY Voltage Frequency Power input/consumption OUTPUTS Voltage / current selectable Accuracy Influence of temperature Effect of load DISPLAY / BUTTON / LED LCD, backlight Micro push button LED red / green HOUSING Corrosion durability Ingreased protection GENERAL Terminal cross-section Cable connections M20x1,5 Dimensions H x W x D Weight MATERIALS Housing Front plate, Screws Seals Cable connection, Sensor connection M12 APPLICATION Ambient- and storage temperature Humidity, without condensation Mountion position...

Open the catalog to page 4
TR.Nc + IY.Nc Manual - 5

TR.Nc / IY.Nc IY.Nc -RT / RTH-… normal condition / Industrieanwendung TEMPERATURE / TEMPERATURE HUMIDITY DEW POINT TYPES AND MEASUREMENT RANGE IY.Nc-RT Room Temperature feeler/probe IY.Nc-RTH Room Temperature-humidity feeler/probe ACCURACY Accuracy temperature @.0 … 60 °C Accuracy temperature @.-40 … 0, @ 60 … 125 °C Accuracy humidity Hysteresis Long term stability 1.000 h / 25 °C MTTF (Sensor) SUPPLY Via M12 interface to TR.Nc MATERIALS Thermowell, end cap Seals Sensor connection M12 APPLICATION Ambient-, storage temperature Humidity, without condensation Mounting position Stainless Steel...

Open the catalog to page 5
TR.Nc + IY.Nc Manual - 6

TR.Nc / IY.Nc normal condition / Industrieanwendung © pi ▪ petz industries GmbH&Co.KG ▪ Mühlenweg 2 ▪ 96358 Teuschnitz / Germany ▪ +49 (0)911 658 18 60 ▪ www.pi-safety-components.de

Open the catalog to page 6
TR.Nc + IY.Nc Manual - 7

TR.Nc / IY.Nc normal condition / Industrieanwendung WALL MOUNTING UNLOCK ELECTRONIC Switch off power and check    Press down release tab carefully Slide electronic module up and Remove forward 87 62 DUCT MOUNTING Drill holes according to the drilling plan (see illustration) Mount base frame with delivered screws. Make sure when mounting that the mounting frame is not under strain or sags For outdoor mounting make sure that no water accumulates or frost can form © pi ▪ petz industries GmbH&Co.KG ▪ Mühlenweg 2 ▪ 96358 Teuschnitz / Germany ▪ +49 (0)911 658 18 60 ▪ www.pi-safety-component

Open the catalog to page 7
TR.Nc + IY.Nc Manual - 8

TR.Nc / IY.Nc normal condition / Industrieanwendung ELECTRICAL CONNECTION LOCK ELECTRONIC The integrated electrical connection box protection enables direct contact to the supply and the analog outputs. Pursuant to IEC61010, the power supply is to be protected with a fuse < 10 A.  Switch off power and check  Unlock electronic part  Remove M3 screw from cover  Open cover  Remove protection of the cable connection  Insert cable  Strip cable (6 mm)  Open clamp by pressing gently with a screwdriver  Slide wire/s in  Remove screwdriver  Close cover  Tighten cable screws  Close...

Open the catalog to page 8
TR.Nc + IY.Nc Manual - 9

TR.Nc / IY.Nc normal condition / Industrieanwendung 9. Calibration analog outputs Make sure that the device is properly installed in accordance with the preceding chapters and has been connected and the power supply with the specifications on the nameplate. The TR.Ex has the menu item "Output calibration" a function in the analog outputs can be checked / calibrated. Turn on the power supply.  Display switches to normal  Sensor data loads  LED lights green when probe/feelers connected and within the set measuring range. In parameterization mode (see Chapter 10) can be preselected volts or...

Open the catalog to page 9
TR.Nc + IY.Nc Manual - 10

TR.Nc / IY.Nc normal condition / Industrieanwendung PARAMETER MODE Push 3 seconds LANGUAGE SETTING D Deutsch GB English F Francais E Espanol I Italiano Select using keys desired language press enter SENSOR SETTING Output mA / Volt Select sensor Select unit Measurement range Offset Select channel Output range Output Sensor error Damping mA Volt temperature relative humidity dew point pressure °C, °F, K, °Ra, %rF, % rH Pa, mbar, …. 0,00 100 0,000 Channel 1 Channel 2 4,00 20,00 normal invers 0 20 1 50 Zero compensation k-Factor Select mA or Volt at the output channels 1 / 2 Select sensor for...

Open the catalog to page 10
TR.Nc + IY.Nc Manual - 11

TR.Nc / IY.Nc normal condition / Industrieanwendung 15. Accessories Spare Parts No Display / LED  Check power supply  Check if mounting frame and electronics are locked No output signal  Check power supply (LED red/green)  Check wiring  Check parameterizing Red LED  Reading out of range  Sensor line break Filter cap pore size 10 µm 1 m M12 cable for remote measurement 5 m M12 cable for remote measurement 10 m M12 cable for remote measurement Cable glands M20x1,5 Ms/Ni Pressure connector M5 to tube 6 mm Pressure connector M5 to tube 4 mm M5 thread enlargement to G1/8” M5 thread...