MoleculUS

MoleculUS

MoleculUS

Product catalog summary
Introduction
MoleculUS™ is a cutting-edge data acquisition platform developed by PhotoSound Technologies, Inc. and Telemed, UAB. It integrates photoacoustic technology with ultrasound imaging, offering advanced capabilities in ultrasonic imaging with chemical analysis.

Specifications
- Maximum Ultrasound Intensity: 720 mW/cm², compliant with IEC 60601-2-37 standards.
- Maximum Ultrasound Power: 2.16 W.
- USPA Channels: 128 channels, with an option for an additional 128 channels for PA mode.
- PA Mode Programmable Gain: 46 to 91 dB.
- Ultrasound Frequency: 1 to 18 MHz.
- Sampling Rate: 40 MSPS.
- Input Impedance: PA Mode: 2.2 MΩ, US Mode: 50 Ω.
- Input Connector: Cannon QLC-260.

Features
The system supports various ultrasound imaging modes including B(2D), M, Color Doppler, and Pulsed Wave Doppler. It allows access to raw frequency data in both modalities and includes a software development kit (SDK) for device software and GUI customization. The system is compatible with a range of probes and can be configured for custom probes.

Technical Requirements
- Minimum PC Requirements: 6th generation Intel® quad-core processor, 8 GB DDR4 RAM, USB3 port, 500 GB PCIe 3.0 x4 SSD, Windows 10 64-bit Home.
- Recommended PC Requirements: 9th generation Intel® hexa-core processor, 16 GB DDR4 RAM, USB3 port, 1 TB PCIe 3.0 x4 SSD, Windows 10 64-bit Pro.

Design and Connectivity
The device includes two medical-grade Cannon QLC-260 probe input connectors, programmable electrical trigger inputs and outputs, optical trigger inputs, a USB 3.0 port, status and diagnostic LEDs, and silent operation cooling fans.

Applications
MoleculUS™ is suitable for various applications including veterinary, abdominal, vascular, cardiac, transrectal, and transvaginal imaging, providing high-resolution images through its diverse probe configurations.

Conclusion
MoleculUS™ represents a significant advancement in ultrasonic imaging technology, combining the strengths of photoacoustic and ultrasound modalities to deliver superior imaging and analysis capabilities.
See more

Catalog excerpts

MoleculUS-1

Build the best data acquisition platform powered by PhotoSound® TM MoleculUS Analysis Ultrasonic Imaging with Chemical PhotoSound Technologies, Inc. and Telemed, UAB are proud to announce their first jointly developed product. MoleculUS™ combines photoacoustics, PhotoSound’s core competence, with the ultrasound core competence of Telemed. The system features 256 photoacoustic channels of data acquisition where 128 channels can be switched between the ultrasonic beamformer and photoacoustic acquisition. The system collects photoacoustic signals while being optically triggered by the laser source and performs ultrasound imaging in between laser pulses. The available US imaging modes are B(2D), M, Color Doppler, Pulsed Wave Doppler and are pre-set. Raw Frequency (RF) data can be accessed in both modalities. The system comes with a software development kit (SDK) that allows customization of the device software and graphical user interface. There is a linear, as well as, a micro-convex probe available as add-ons but the system is configurable for custom probes. Standalone control software based on MATLAB® and backend SDK written in C++ compatible with many frontend languages such as LabView, MATLAB® and Python TM Maximum Ultrasound Intensity Maximum Ultrasound Power USPA Channels (1) PA Mode Programmable Gain (2) Ultrasound Frequency (3) Sampling Rate PA Mode Input Impedance US Input Impedance Input Connector (4) Available US Modes 720 mW/cm², in compliance with requirements of the standard IEC 60601-2-37. 2.16 W 128 46 to 91 dB Configuration with extra 128-channels for PA mode only is available (increases housing size) Measured with 50Ω load (actual gain depe nds on probe capacitance) See list of available US probes or ask about third -party probe compatibility and optimization Additional connector for extra 128 -channels for PA mode only (128 -channels per connector) B(2D), M, Color Doppler, Pulsed W

 Open the catalog to page 1
MoleculUS-2

Two op tical trigger inputs for connecting patch fibers allow precise triggering from external light source USB 3.0 port for high data transmission Status and diagnostic LEDs Two sets of programmable electrical trigger input and output (isolated SMA connectors) Two medical grade Cannon QLC-260 probe input connectors for both US and PA modes Two 12VDC 5A (P A mode) and 2.5A (US mode) power connectors (power supplies included) 7. Two 40 mm silent operation cooling fans All dimensions approximate in millimeters (mm). Weight 7.2 lbs (3.3 A variety of probes are available that offer high resolution...