1. Catalogs
  2. PhotonTec Berlin GmbH
  3. High Resolution Serie - Aurora 4000

High Resolution Serie - Aurora 4000

High Resolution Serie - Aurora 4000

High Resolution Serie - Aurora 4000

Product catalog summary
Overview: The Aurora4000 is a high-resolution spectrometer designed by PhotonTec Berlin GmbH, offering customizable wavelength ranges and resolutions suitable for various applications.
Features:
  • Optical resolution up to 0.02nm (FWHM).
  • Customizable wavelength range and resolution.
  • Suitable for laser, fluorescence, Raman spectral analysis, film thickness measurement, reflectivity/transmittance measurement, biological cell analysis, and LED analysis.
Models and Specifications:
  • General Series: GE 350-1100nm, GE 200-1100nm, GE Raman.
  • External Triggering Series: TG 350-1100nm, TG 200-1100nm.
  • Optical resolution varies with slit width and wavelength range, with detailed specifications provided in tabular form.
Detector:
  • Uses Toshiba TCD1304DG linear CCD array.
  • Wavelength range: 200-1100nm.
  • 3648 pixels with a pixel size of 8um*200um.
  • Sensitivity: 130 photons/count at 400nm, 60 photons/count at 600nm.
Physical and Performance Specifications:
  • Dimensions: 149mm x 105mm x 46mm; Weight: 840g.
  • Optical resolution: <0.75nm FWHM.
  • Signal-to-noise ratio: 300:1 at full signal.
  • Dark noise: 12 RMS counts; Dynamic range: Integration time 4ms-10s.
  • Stray light: <0.05%@600nm; <0.10%@435nm.
  • Corrected linearity: >99.8%.
Optical Bench:
  • Design: f/4, Symmetrical crossed Czerny-Turner.
  • Focal length: 101.6mm input and output.
  • Entrance aperture options: 5, 10, 25, 50, 100, or 200 um.
  • Grating: Various options for ultraviolet and infrared.
  • Fiber optic connector: SMA905 to 0.22 numerical aperture single-strand fiber.
Electronics:
  • Power consumption: 450mA@5VDC.
  • Trigger mode: 4 species.
  • Data transfer speed: Full scans into memory every 4 milliseconds with USB 2.0; every 18 milliseconds with USB 1.1.
  • Inputs/outputs: 5 inputs and 5 outputs (opto-isolator inputs/outputs).
  • Analog channels: One 12 analog input, one 12 analog output.
  • Connector: 30-pin connector.
See more

Catalog excerpts

High Resolution Serie - Aurora 4000-1

High Resolatuion Spectrometer – Aurora4000 Features: Up to 0.02nm (FWHM) optical resolution Customized wavelength range and resolution Fit various applications Applications: Laser spectral analysis Fluorescence spectral analysis Raman spectral analysis Film thickness measurement Reflectivity/transmittance measurement Biological cell analysis LED analysis Aurora4000 External Triggering series Slit width (µm) Wavelength range (nm) PhotonTec Berlin GmbH | Max-Planck-Str. 3 | 12489 Berlin, Germany Tel.: +49-30-834093-80 | Fax. +49-30-834093-81 [email protected] | www.photontec-berlin.com

 Open the catalog to page 1
High Resolution Serie - Aurora 4000-2

Detector Detector Toshiba TCD1304DG linear CCD array Wavelength range Pixel size Optical resolution Signal-to-noise ratio Dark noise Dynamic range Integration time Stray light Corrected linearity Optical Bench Design f/4, Symmetrical crossed Czerny-Turner Focal length A variety of different grating, ultraviolet and infrared Fiber optic connector SMA905 to 0.22 numerical aperture single-strand fiber Electronics Power consumption Trigger mode Data transfer speed Full scans into memory every 4 milliseconds with USB 2.0; every 18 milliseconds with USB 1.1 5 inputs and 5 outputs (opto-isolator inputs/outputs)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.