1. Catalogs
  2. PHOTONIS
  3. MANGUM 5900 series
video corpo

MANGUM 5900 series

MANGUM 5900 series

MANGUM 5900 series

Product catalog summary
Overview: The Electron Multiplier MAGNUM is designed for use in mass spectrometers, offering high mass resolution, wide dynamic range, low noise, and long life. It features a unique six-channel design and is suitable for high-pressure and high-dynamic-range applications.
Specifications: The MAGNUM series includes models 5900 to 5905, each with specific applications and replacement capabilities for various brands like Agilent, Bruker, Hitachi, and Thermo Finnigan. The operating voltage is up to 3000 V, with a maximum dark current of 1 x 10-12 A at 2500 V and a maximum dark count of 120 counts in 60 seconds at 3000 V. The operating temperature ranges from -50 to 120º C, and the maximum vacuum bake temperature is 350º C.
Features: The MAGNUM multipliers offer high sensitivity, easy replacement, and a unique Spiraltron™ design for higher gain and longer life. They are compact and plug-in ready, making them ideal for various applications.
Performance: The multipliers provide a typical gain of 1 x 107 to 5 x 107 at 2500 V, with a bias current range of 60 to 167 µA. The resistance varies from 16 to 50 MΩ, and the bias resistor is nominally 10 to 20% of the total resistance.
Applications: These multipliers are used for mass spectrometer replacements and are compatible with high-pressure environments. They are designed for high dynamic range and compact applications.
Additional Information: The document notes that the information is believed to be accurate but is subject to change without notice. Customers are advised to verify the most current product information before placing orders.
See more

Catalog excerpts

MANGUM 5900 series-1

Electron Multiplier MAGNUM Electron Multiplier™ 5900 Series Applications Mass spectrometer replacements High pressure High dynamic range Compact, plug-in applications Unique SPIRALTRON™ Design High mass resolution Wide dynamic range Low noise Long life High sensitivity Easy replacement Unique 6-channel design MAGNUM Replacement Multipliers 5900 MAGNUM 5901 MAGNUM 5902 MAGNUM 5903 MAGNUM 5904 MAGNUM 5905 MAGNUM Analog, HP replacement Pulse Counting Analog, Bruker, Hitachi, HP/K&M replacement Analog, Thermo Finnigan, Dionex replacement Analog, Bear and Varian replacement Analog , Thermo Finnegan replacement Six channel construction Single inlet aperture Longer multiplier life MAGNUM in Agilent Detector MAGNUM in Bruker Detector Higher Gain and Longer Life

 Open the catalog to page 1
MANGUM 5900 series-2

Electron Multiplier MAGNUM specifications MAGNUM Spec Number EDR Spec MODE Pulse Counting Max Pulse Height Distribution Max Operating Pressure Operating Voltage 120 counts in 60 seconds (at 3000 V) 10 to 20% of Total Resistance Bias Resistor (nominally) Max Vacuum Bake Operating Temperature Other compact PHOTONIS Multipliers for high pressure applications Spiraltron™ up to 1 x 10-3 Torr MegaSpiraltron™ up to 10-2 Torr (standard and EDR) The information furnished is believed to be accurate and reliable, but is not guaranteed and is subject to change without notice. No liability is assumed by PHOTONIS...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.