Overview: The document describes the PHOTONIS Ion Mobility Spectrometer (IMS) Engine, a patented technology designed for fast and accurate sample analysis with minimal preparation. It highlights the engine's high resolving power, sensitivity, and compatibility with various ionization sources.
Key Features:
  • High Resolving Power: Ranges from 64 to 150, allowing for precise analysis.
  • High Sensitivity: Capable of detecting 19 picograms of DtBP.
  • Robust Ion Gate: Utilizes a Bradbury-Nielsen type ion gate for improved performance and ease of maintenance.
  • Compatibility: Can integrate with IMS-MS systems and supports multiple ionization sources such as DESI, DART, Electrospray, Corona Discharge, and Radiation.
  • Customizable: The platform can be tailored to specific applications and scaled as needed.
Technical Specifications:
  • Physical Characteristics: Reaction and Drift Tube ID is a minimum of 30 mm, with a Drift Tube Length of 250 mm.
  • Electrical Characteristics: Operates on AC power with a high voltage range up to 15 kV and a maximum heater temperature of 125°C.
  • Performance: Resolving power of at least 60, with sample analysis time under 10 seconds and a warm-up time of 30 minutes.
  • Gas Requirements: Uses ultra-high purity nitrogen at a consumption rate of 1 l/m.
Innovative Design: The IMS Engine features Resistive Glass technology for the reaction and drift tubes, providing uniform electric fields and minimal divergence. This design enhances resolving power and simplifies the system by eliminating the need for additional containment.
Co-Development Model: PHOTONIS collaborates with customers to develop custom solutions, leveraging joint engineering efforts to bring products to market efficiently.
Contact Information: For more details or to order, contact PHOTONIS USA at [email protected] or call +1 (508) 347 4000.
See more

Catalog excerpts

ION MOBILITY SPECTROMETER (IMS) ANALYZER-1

Advanced IMS Analysis with High Resolving Power Ion Mobility Spectrometer Engine Patented technology enables fast, accurate results with simple sample preparation. High Resolving Power (64-150) High Sensitivity (19pg DtBP) Robust Ion Gate IMS-MS Compatible Microprocessor Control Easily Integrates with MS Software Use with Multiple Sources, API techniques Customize to Various Sources: • • • • • DESI DART Electrospray Corona Discharge Radiation The PHOTONIS Ion Mobility Spectrometer Engine is a patented platform that can be customized for a variety of specific applications where samples need to be quickly identified. Its unique design allows the user to quickly and inexpensively perform a simple IMS analysis and receive fast, accurate results even at room temperature sampling. It can be designed to operate with any number of ionization sources, can be scaled or customized, or can operate as a stand-alone unit. PHOTONIS' IMS Engine is a complete integrated unit which includes reaction and drift tubes, a high-performance ion gate, heater and integrated gas controls. The new PHOTONIS IMS Engine features a range of innovative technologies which combine to provide significantly higher resolving power when compared to currently available commercial IMS instruments, producing values ranging from 64-150. This IMS unit also features a new, robust ion gate technology which improves resolution and simplifies serviceability. Key components of the IMS Engine are made from Resistive Glass to replace conventional lens assemblies. In this patented platform, the reaction and drift tubes are comprised of Resistive Glass, providing a one-piece construction that produces minimal divergence and uniform counter flow of drift gas without the need for additional containment. The new PHOTONIS IMS Engine provides a compact and reliable analysis platform with improved performance. Its high resolving power and robust photo-etched ion gate make it ideal for use in a variety of applications where high volume, accuracy and speed of identification is critical to applications such as those involving product safety, composition analysis and environmental control. PHOTONIS' ability to design custom prototypes and develop them into full-scale production is unsurpassed in the detector and sensor industry. Schedule your technology assessment with PHOTONIS to see how our patented IMS analysis engine can improve your sample analysis. 660 Main Street, Sturbridge, MA USA 01566

 Open the catalog to page 1
ION MOBILITY SPECTROMETER (IMS) ANALYZER-2

Ion Mobility Spectrometer Engine Specifications: Patented Technology Physical Characteristics Reaction and Drift Tube ID Drift Tube Length Electrical Characteristics AC Power: High Voltage Range The use of Resistive Glass technology in Ion Mobility Spectrometers creates highly uniform electric fields that guide analyte ions to the detector with minimal divergence, resulting in higher resolving power. Drift and reaction tubes are one-piece construction that enables the uniform counter-flow of gas without the need for additional containment. Resistive Glass tubes are only available from PHOTONIS and...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.